Submissions closed on 22 June 2026. The information below is archived for reference.
Our AI analyzes thousands of tenders and finds the ones YOUR company can actually win
AI Match Scoring
Get a compatibility score for every new tender
Instant Notifications
Get alerted when 85%+ matches appear
Gap Analysis
See exactly what you need to qualify
B-BBEE Matching
Tenders matched to your certification level
Province Targeting
Only see tenders in your regions
Document Readiness
Know if you have required docs before using AI assistance
Reference
E2969GXMPKRI
Organization
Eskom
Province
Mpumalanga
Closed
22 June 2026
Categories
Don't worry! Here are similar opportunities still open for submission
AI Document Analysis Stages
We refine every tender document through these stages so you can brief your team and prepare your bid with confidence. Anything marked as "in progress" will be upgraded automatically — no action required from you.
AI Document Analysis Stages
Review in progress
The information shown on this card is preliminary. Our procurement team is currently finalising the submission guidelines, evaluation criteria, technical specifications, financial requirements, and compliance sections so you have a clean, bid-ready summary to work from. Documents being finalised: 240-105658000 Supplier Quality Management Specification (3).pdf, 240-68099512 Form A_Cat 2_ Rev 9.pdf, 240-109253698 CQP Template 2021.pdf and 15 more. You don’t need to refresh — this page will pick up the updated review automatically.
Government tenders in the Services: General sector represent significant opportunities for South African businesses. The South African government regularly procures goods and services through the eTender portal, making it essential for businesses to stay informed about new opportunities.
Get weekly tender digests and industry insights delivered to your inbox.
Subscribe for FreeWe refine every tender document through these stages so you can brief your team and prepare your bid with confidence. Anything marked as "in progress" will be upgraded automatically — no action required from you.
Important Dates
Source: 240-105658000 Supplier Quality Management Specification (3).pdfClosing date: 22 June 2026 at 10:00 AM (UTC).
Submission Guidelines
Source: 240-105658000 Supplier Quality Management Specification (3).pdfSubmit the following returnable documents as per the tender category (1-4) specified in Form A:
Evaluation Criteria
Source: 240-105658000 Supplier Quality Management Specification (3).pdfEligibility and scoring are based on the following:
Technical Specifications
Source: 240-105658000 Supplier Quality Management Specification (3).pdfScope: Hiring, installation, and operation of suspended platforms and mobile lifts on an 'as and when' basis for 5 years at Kriel Power Station.
Key Requirements:
Compliance Requirements
Source: 240-105658000 Supplier Quality Management Specification (3).pdfMandatory compliance requirements:
Submission Guidelines
Source: 240-68099512 Form A_Cat 2_ Rev 9.pdfEvaluation Criteria
Source: 240-68099512 Form A_Cat 2_ Rev 9.pdfTechnical Specifications
Source: 240-68099512 Form A_Cat 2_ Rev 9.pdfCompliance Requirements
Source: 240-68099512 Form A_Cat 2_ Rev 9.pdfImportant Dates
Source: 240-109253698 CQP Template 2021.pdfTemplate-specific dates only: Effective Date: 01 April 2021, Next Review Date: 01 April 2026. Note: These are not tender deadlines. Refer to the tender listing for actual closing date and other critical dates.
Submission Guidelines
Source: 240-109253698 CQP Template 2021.pdfRequired submission: Complete and submit the Contract Quality Plan (CQP) template as part of your tender. Key actions: Fill in Supplier/Contract Name, Eskom Enquiry/Contract Number, and all 20 sections of the template. Ensure sections are fully addressed, including quality management procedures, resources, and processes. The template must be submitted per the tender’s instructions.
Evaluation Criteria
Source: 240-109253698 CQP Template 2021.pdfQualification requirement: Demonstrate a robust Quality Management System (QMS) capable of meeting Eskom’s detailed planning, control, monitoring, and documentation requirements. Evaluation focus: Comprehensive completion of all 20 sections of the CQP template, including quality practices, standards, and compliance with SANS 466:2005 / ISO 10005:2005. No explicit scoring method or thresholds are provided in this document.
Technical Specifications
Source: 240-109253698 CQP Template 2021.pdfScope: Hiring, installation, and operation of suspended platforms and mobile lifts on an 'as and when' required basis at Kriel Power Station for five years. Template requirements: Define the full scope of work in the CQP, including: Applicable scope categories (e.g., Construction/Installation/Maintenance). Communication channels with Eskom (e.g., emails, meetings, reporting). Organogram with roles, responsibilities, and qualifications. List of interfacing documents (processes, standards, codes, specifications). Suppliers/sub-suppliers and their monitoring plans. Index of items to be manufactured/refurbished/purchased. Quality control plans for onsite/offsite activities. Special controls for processes (e.g., welding, NDT/NDE). Documented information to be submitted to Eskom (e.g., QCP/ITP, certificates, inspection reports). Records control, concession/non-conformance management, databook management, tools/equipment management, customer property handling, product preservation, identification/traceability, and commissioning/post-delivery activities.
Submission Guidelines
Source: Environmental -Eskom's (SHEQ) Policy poster REV 8.pdfReturnable Documents: Not specified in the provided text.
Evaluation Criteria
Source: 240-109253302 _ Quality Control Plan or Inspection Test Plan (QCP or ITP) rev 2.pdfGeneral: Applicants must be legally registered entities capable of providing the required services. Compliance with South African regulatory and statutory requirements for equipment and operations is mandatory. Experience in providing similar services for power stations or industrial facilities is advantageous. Technical: Certification or accreditation for inspection and testing methods (e.g., NDT, TPI) is required. Must meet Eskom’s quality control and safety standards, including third-party inspections where applicable. Proven track record in hiring, installing, and operating suspended platforms and mobile lifts is essential. Documentation: Must produce and maintain documentation aligned with Eskom’s QCP/ITP templates and review processes. Must comply with Eskom’s document control policies (e.g., uncontrolled copies are the user’s responsibility).
Technical Specifications
Source: 240-109253302 _ Quality Control Plan or Inspection Test Plan (QCP or ITP) rev 2.pdfScope: Hiring, installation, and operation of suspended platforms and mobile lifts at Kriel Power Station on an as-and-when-required basis for five years. Requirements: Submit a detailed Quality Control Plan/Inspection and Test Plan (QCP/ITP) with: Activities, intervention points, inspection/test methods, and acceptance criteria. Intervention Point Categories: Hold Point, Witness Point, Surveillance (S), Verification (V). Inspection Types: 100% Testing (T1), Sample Testing (T2), 100% Inspection (A1), Sample Inspection (A2), 100% Witness (W1), Sample Witness (W2), 100% Document Review (R1), Sample Document Review (R2). Inspection Methods: Visual, Microscopy, NDT, Liquid/Dye Penetrant, Magnetic Particle, EDDY. Acceptance Criteria: Functionality requirements, performance measures, regulatory compliance, chemical tests. Abbreviations: NOBO (Notification Body), TPI (Third Party Inspection).
Evaluation Criteria
Source: Installation and operation of Suspended Platforms Technical Scope of work.pdf_.pdfTechnical evaluation based on: Compliance with Generation Tender Technical Evaluation Procedure (240-168966153), WCOU Power Plant Maintenance Fall Protection Plan (240-154119722), Work at Height Standard (32-418), and all referenced SANS standards. Mandatory criteria: Capability to supply trained/qualified operators, at least one technician, semi-skilled personnel, and required equipment for 5-year service period. Acceptable/unacceptable risks will be assessed per tender technical evaluation strategy.
Technical Specifications
Source: Installation and operation of Suspended Platforms Technical Scope of work.pdf_.pdfScope: Supply labour (trained/qualified operators, at least one technician, semi-skilled personnel) and equipment for hiring, installation, operation, and dismantling of suspended platforms and mobile lifts at Kriel Power Station for 5 years. Work areas: Primarily inside boilers (front, rear, left/right sides, divisional walls) with suspended platforms (minimum 4-person capacity per platform: 4x front, 4x rear, 2x LHS, 2x RHS, 2x LHS divisional wall, 2x RHS divisional wall). Mobile lifts: Hire, operation, installation, dismantling at Allimak stations or other areas as required by Eskom. Tasks: Mostly during outages, but may include pre- or post-outage work as directed by the contract manager. Tools: Contractor must provide all necessary basic tools for suspended platform operations. Standards: Compliance with SANS 51808 (suspended access equipment), SANS 10295-2 (Temporary Suspended Platforms), SANS 16368/18893 (Mobile Elevating Work Platforms), SANS 1397 (Industrial Safety Helmets), and Eskom standards (32-418 Work at Height, 34-1507 Fall Arrest Systems, 34-1710 PPE, 34-323 PPE Specification).
Submission Guidelines
Source: Annexure B.pdfThis document (Annexure B) is an OHS Acknowledgement Form, not the main tender submission document. It must be signed and returned as part of the bid submission. Requirements for this form: authorized signatory (CEO/Director/Managing Director) must sign and date it, and two witnesses must sign. Suppliers must acknowledge receipt and understanding of all listed OHS documents.
Evaluation Criteria
Source: Annexure B.pdfExplicit scoring criteria are not provided in this annexure. However, the following are implied eligibility factors: supplier's demonstrable capability and commitment to meet Eskom’s OHS management framework; processes for subcontractor management; and a history of compliant work, as Eskom may request references or testimonials.
Compliance Requirements
Source: Annexure B.pdfMANDATORY OHS COMPLIANCE REQUIREMENTS: Suppliers/contractors must comply with the following Eskom and statutory documents: Eskom Contractor Health and Safety Requirements Standards 32-136; OHS Specification/Requirements (provided separately); Occupational Health and Safety Act; Compensation for Occupational Diseases and Illnesses Act; 32-727 SHEQ Policy; National Road Traffic Act; 32-37 Eskom Substance Abuse Procedure; 240-62196227 Life-saving Rules; 240-62946386 Vehicle and Driver Safety Management; 32-95 OH&S Incident Management Procedure; 32-726 Contract and Contractor OHS Management. KEY OBLIGATIONS: After contract award, supplier must fully align company processes to Eskom OHS requirements. Penalties will be enforced for non-conformance by the main supplier, its contractors, or suppliers. All employees must undergo relevant Eskom induction. Main contractor must: demonstrate selection criteria for appointing sub-contractors; notify Eskom before appointing contractors; ensure contractors have adequate resources and competencies; manage all tiers of contractors/suppliers; monitor contractors through audits and assessments for OHS compliance. Eskom reserves the right to verify compliance and request testimonials/references. All non-conformances will be dealt with through performance and penalty processes. The signed acknowledgement form must be submitted with bid documents.
Important Dates
Source: Eskom - Standard Conditions of Tender - 30 January 2025.pdfContact Information
Source: Eskom - Standard Conditions of Tender - 30 January 2025.pdfSubmission Guidelines
Source: Eskom - Standard Conditions of Tender - 30 January 2025.pdfEvaluation Criteria
Source: Eskom - Standard Conditions of Tender - 30 January 2025.pdfTechnical Specifications
Source: Eskom - Standard Conditions of Tender - 30 January 2025.pdfFinancial Requirements
Source: Eskom - Standard Conditions of Tender - 30 January 2025.pdfCompliance Requirements
Source: Eskom - Standard Conditions of Tender - 30 January 2025.pdfImportant Dates
Source: Invitation to Tender (ITT) Rev. 28 - 21 April 2026_Suspended Platforms.pdfContact Information
Source: Invitation to Tender (ITT) Rev. 28 - 21 April 2026_Suspended Platforms.pdfSubmission Guidelines
Source: Invitation to Tender (ITT) Rev. 28 - 21 April 2026_Suspended Platforms.pdfEvaluation Criteria
Source: Invitation to Tender (ITT) Rev. 28 - 21 April 2026_Suspended Platforms.pdfTechnical Specifications
Source: Invitation to Tender (ITT) Rev. 28 - 21 April 2026_Suspended Platforms.pdfFinancial Requirements
Source: Invitation to Tender (ITT) Rev. 28 - 21 April 2026_Suspended Platforms.pdfCompliance Requirements
Source: Invitation to Tender (ITT) Rev. 28 - 21 April 2026_Suspended Platforms.pdfContact Information
Source: Eskom_Supplier_Integrity_Pact_-_02_June_2023.pdfFor reporting dishonest, fraudulent, or inappropriate behavior: email [email protected] or [email protected], or call the toll-free hotline 0800 11 27 22. Confidentiality is guaranteed.
Evaluation Criteria
Source: Eskom_Supplier_Integrity_Pact_-_02_June_2023.pdfThe Eskom Supplier Integrity Pact applies to all existing and potential Eskom suppliers (registered vendors). Key eligibility hinges on compliance with ethical standards outlined in this document. Suppliers must be willing to undergo Eskom’s supplier discipline process if found in violation. Specific technical or commercial evaluation criteria for the Kriel Power Station tender are not contained in this document.
Compliance Requirements
Source: Eskom_Supplier_Integrity_Pact_-_02_June_2023.pdfMandatory for all Eskom tenders: Suppliers must read, sign, and submit the Integrity Declaration Form when participating in any Eskom procurement process. Additional requirements: Complete a Non-Disclosure Agreement (NDA) if accessing confidential information. Disclose any financial, personal, or private interest with an Eskom employee/director via the Integrity Declaration Form. Gifts to Eskom employees must not exceed R1,500 in value. Note: This document does not contain tender-specific compliance requirements (e.g., CSD, tax clearance, B-BBEE, CIDB). Obtain the full tender document for the suspended platforms and mobile lifts tender to confirm specific compliance obligations.
Important Dates
Source: NEC TSC_Suspended Platforms.pdfContract period: 5 years from the signature date. Payment assessment: 25th of each month (bi-weekly assessments may be requested by the Service Manager). Response times: 2 working days for non-outage periods, 12 hours for outages (including weekends/public holidays), 24 hours for maintenance work.
Contact Information
Source: NEC TSC_Suspended Platforms.pdfEmployer: Eskom Holdings SOC Ltd, Megawatt Park, Maxwell Drive, Sandton, Johannesburg. Tel: 011 871 3706. Service Manager: Landizwe Njapha, Kriel Power Station, Ogies/Bethal Road, Kriel, 2271. Tel: 017 615 2518. Email: [email protected].
Submission Guidelines
Source: NEC TSC_Suspended Platforms.pdfSubmit the completed Form of Offer and Acceptance (C1.1), including the Schedule of Deviations if applicable. The offer becomes binding once signed. Include your CIDB registration number in the submission. After contract award, contact the Employer’s agent within two weeks to deliver securities, bonds, guarantees, proof of insurance, and other required documentation. Failure to comply may result in contract repudiation.
Evaluation Criteria
Source: NEC TSC_Suspended Platforms.pdfEvaluation is based on compliance with the following: Contractor must be a legally registered entity. CIDB registration is mandatory. B-BBEE compliance is required; any post-award decrease in B-BBEE status must be reported within 7 days and may lead to contract renegotiation or termination. Joint ventures are permitted but all members are jointly and severally liable. Contractor cannot cede, delegate, or assign rights without Eskom’s written consent.
Technical Specifications
Source: NEC TSC_Suspended Platforms.pdfScope: Hiring, installation, and operation of suspended platforms and mobile lifts on an 'as and when' required basis for 5 years at Kriel Power Station. Service Information is detailed in Part C3 (Scope of Work). Contractor must submit a Level 3 plan within one week of the contract date. Compliance with all health, safety, and environmental laws is mandatory, including Eskom’s Asbestos Standard (32-303). Risk Register must include quality-related issues and force majeure events (e.g., protests, COVID-19 restrictions).
Financial Requirements
Source: NEC TSC_Suspended Platforms.pdfContract type: NEC3 Term Service Contract Option A (Priced contract with price list). Pricing: Lump sums or rates multiplied by quantities from the Price List (C2.2). Payment terms: Assessment on the 25th of each month (bi-weekly if requested). Payments made within 14 or 30 days per Eskom Finance Procedures. Tax invoices must be submitted within one week of receiving a payment certificate, including Eskom’s VAT number (4740101508). Interest rate: Standard Bank prime rate. Price adjustments for inflation apply 12 months after contract start (linked to SEIFSA indices).
Compliance Requirements
Source: NEC TSC_Suspended Platforms.pdfCIDB registration is mandatory. B-BBEE: Must notify Eskom within 7 days of any status change and submit an updated verification certificate within 30 days. A decrease in B-BBEE status may lead to contract renegotiation or termination. Insurance: Contractor must provide cover as per Insurance Table A (property damage, liability, employee injury) from the start date. Joint ventures: All members are jointly and severally liable; composition changes require Eskom’s written consent. Confidentiality, ethics, and anti-corruption clauses (Z11) apply. Compliance with all South African laws, including OHSA Construction Regulations 2014, is required.
Evaluation Criteria
Source: Safety file checklist.pdfMandatory criteria:
Contractor Supervisor and Safety Officer
OHS Representatives and SHE Committee Chairman
Operators and inspectors for lifting machinery (DMR 18)
Competent person for Fall Protection Plan (32-418)
Competent person for suspended platforms
Preferred criteria:
Technical Specifications
Source: Safety file checklist.pdfScope: Hiring, installation, and operation of suspended platforms and mobile lifts on an 'as and when' required basis at Kriel Power Station for a period of five years.
Key requirements:
Contractor Supervisor and Safety Officer (full-time or part-time with defined visit frequency)
OHS Representatives (if more than 20 employees or risk-based)
SHE Committee Chairman
Competent person to conduct investigations (GAR 9(2))
First Aider (GSR 3(4))
Operators and inspectors for lifting machinery, lifting tackle, and forklifts (DMR 18)
Competent person to prepare and implement a Fall Protection Plan (32-418)
Competent person for suspended platforms (OHS Act)
Competent person for scaffolding (SANS 10085)
Risk identification, analysis, and controls (32-520)
Risk matrix and rating
Monitoring and review plans
Working at heights: Fall protection plan, rescue plan, risk assessment, employee training, medical fitness assessments, and planned inspections of fall protection equipment (32-418).
Confined spaces: Risk assessment, safe work procedures, PPE (e.g., breathing equipment, safety harness), competency training, medical fitness certificates, and emergency evacuation/rescue plans.
Vehicle safety: Inspection checklists, lists of vehicles onsite, first aid kits, fire extinguishers, and displayed emergency numbers.
Scaffold, fall protection equipment, lifting machines, and lifting tackle (DMR 18, SANS 10085)
Vessels under pressure and fire extinguishers (PER 11)
Portable electric lights (EMR 11)
Material hoists, mobile plants, and temporary electrical installations
PPE inspections and issuance registers
Toolbox talks and behaviour-based inspections
Compliance Requirements
Source: Safety file checklist.pdfPrimary compliance is with the Occupational Health and Safety (OHS) Act and its associated regulations. Key requirements include:
General Administrative Regulations (GAR)
General Safety Regulations (GSR)
Driven Machinery Regulations (DMR 18)
SANS 10085 (scaffolding)
Eskom internal specifications (e.g., 32-418 for fall protection, 32-520 for risk assessment, 32-95 for incident management, 32-345 for vehicle safety).
Workplace plan, policy, and risk assessment as per the National Disaster Management Act.
Designated COVID-19 Compliance Officer.
Certificate of system design for suspended platforms (OHS Act).
Proof of competencies for erectors, operators, and inspectors (OHS Act).
Medical fitness certificates for employees working at heights or in confined spaces.
Accreditation certificate for First Aid training service provider (GSR 3).
ID copies of all personnel.
Records of induction programmes, training matrices, and toolbox talks.
Incident management procedure aligned with 32-95, including initial notification and investigation templates, incident register, and WCL forms.
Endorsement of SHE Representative inspections and minutes by the OHS Committee Chairperson (GAR 8).
Chemical Agents and Safety Data Sheets (HCAR 3).
Worker’s timesheets or daily attendance registers.
Important Dates
Source: 240-12248652_List of Tender Returnables_Cat 2_ Rev 7.pdfClosing date for submissions: 2026-06-22 at 10:00.
Submission Guidelines
Source: 240-12248652_List of Tender Returnables_Cat 2_ Rev 7.pdfSubmit all tender returnable documents as listed in the List of Tender Returnables (Specification 240-105658000, Revision 7). Returnables are divided into five sections (A to E), each with mandatory deliverables (indicator = 1). All listed items in applicable sections must be submitted to score points. Sections include: Quality Management System (A), Evidence of QMS in operation (B), Contract Quality Plan (C), Quality Control Plan (D), and User-defined additional requirements (E). Ensure Form A is completed and signed. Submission deadline: 2026-06-22 at 10:00.
Evaluation Criteria
Source: 240-12248652_List of Tender Returnables_Cat 2_ Rev 7.pdfMandatory criteria: Compliance with ISO 9001:2015 via either (Option 1) valid certification from an internationally accredited body (4 points) or (Option 2) objective evidence of a documented QMS complying with ISO 9001:2015 (7 points). Submission of all tender returnable documents (Sections A-E) is required. Ability to provide services at Kriel Power Station as needed. Preferred criteria: Experience in similar projects (e.g., suspended platforms/mobile lifts in industrial settings). Scoring: Section A (4 or 7 points), Section B (4 points), Section C (1 point), Section D (1 point), Section E (2 points).
Technical Specifications
Source: 240-12248652_List of Tender Returnables_Cat 2_ Rev 7.pdfScope: Hiring, installation, and operation of suspended platforms and mobile lifts on an 'as and when' required basis for five years at Kriel Power Station. Deliverables: Draft Contract Quality Plan (specific to scope, Ref: 240-105658000, 240-109253698) and Quality Control Plans/ITP (Ref: 240-105658000 or 240-109253302). Quality deliverables must align with ISO 10005 and the scope of work. Bidders must provide documented evidence of QMS relevant to suspended platform and mobile lift services.
Compliance Requirements
Source: 240-12248652_List of Tender Returnables_Cat 2_ Rev 7.pdfPrimary standard: ISO 9001:2015 compliance. Bidders must either: (Option 1) Hold valid ISO 9001 certification from an internationally accredited body, with product/service scoping defined and relevant, or (Option 2) Provide objective evidence of a documented QMS complying with ISO 9001:2015. Key clauses: Document and record control (7.5), control of nonconforming outputs (8.7), nonconformity and corrective action (10.2), internal audit (9.2), control of externally provided processes/products/services (8.4), and management review records. Additional: Form A must be completed and signed.
Important Dates
Source: SHE SPEC- platform.pdfClosing date for submissions: 22 June 2026 at 10:00 AM.
Contact Information
Source: SHE SPEC- platform.pdfEskom’s Contract Manager/Project Manager: Landizwe Njapha. Eskom’s OHS/SHE Manager: Gift Mamize (Acting). Eskom’s Procurement Officer: Phumelele Mncwango. Eskom’s OHS/SHE Officer: Sizani Shabangu. Project Address: Kriel Power Station, Mpumalanga.
Submission Guidelines
Source: SHE SPEC- platform.pdfSubmit the following returnable documents as part of your bid: Signed Section 37(2) legal agreement between Eskom Kriel Power Station and the main contractor. OHS file containing all relevant health and safety records for each work site. Organisational organogram on company letterhead, signed by the 16(1) or 16(2) appointee, detailing all levels of responsibility from CEO to supervisors. Valid Letter of Good Standing (LoG) from the Compensation Commissioner, kept current throughout the contract. COVID-19 policy signed by the most senior person, including a risk assessment and detailed prevention plan. SHEQ policy signed by the CEO or appointed assistant, displayed prominently and filed in the OHS plan. Proof of OHS training and a costing breakdown for OHS-related expenses (training, PPE, safety equipment, safety file maintenance). Risk assessments and safe work procedures/method statements for all tasks. Medical surveillance programme records and pre-employment/annual medical certificates for all employees. PPE issuance, maintenance, and inspection records. Vehicle inspection checklists and roadworthiness certificates. Ensure all documents are up-to-date, filed in the OHS file, and submitted with the OHS plan.
Evaluation Criteria
Source: SHE SPEC- platform.pdfContractors will be evaluated on the following: Legal registration as an entity with valid COID registration and Letter of Good Standing. Capacity to appoint competent persons for all statutory and non-statutory OHS roles (e.g., Incident Investigator, Health and Safety Representative, First Aider, Fall Protection Plan Developer). Ability to develop and implement a comprehensive OHS Plan meeting Eskom and legislative standards. Compliance with Eskom’s Life-Saving Rules (electrical safety, working at height, seat belt use, sobriety, permit-to-work, safe live working). Demonstration of zero-tolerance substance abuse policy and adherence to Eskom’s Substance Abuse Procedure (32-37). Prohibition of child labour as per the Constitution and Basic Conditions of Employment Act. Submission of detailed COVID-19 risk assessments and control measures, including adherence to National Disaster Management Act requirements.
Technical Specifications
Source: SHE SPEC- platform.pdfScope: Hiring, installation, and operation of suspended platforms and mobile lifts on an 'as and when' required basis for five years at Kriel Power Station. Key Requirements: Develop and implement an OHS plan meeting Eskom and legislative standards (OHS Act, NEMA, National Road Traffic Act, COIDA). Comply with Eskom’s six Life-Saving Rules: OPEN/ISOLATE/TEST/EARTH before touch, hook up at height, buckle up, be sober, ensure permit to work, and ensure safe live working. Conduct pre-task risk assessments, daily toolbox talks, and pre-job meetings. Provide fall protection plans for all work at height, including rescue plans and trained rescuers. Ensure all employees are medically fit for high-risk tasks (annual medical certificates). Appoint competent personnel for statutory roles (e.g., Incident Investigator, Health and Safety Representative, First Aider, Hazardous Chemical Substances Coordinator). Maintain fire equipment, first aid boxes, and PPE as per SANS standards (e.g., SANS 1186 for safety signs). Manage vehicle safety: roadworthiness, seat belts, load securing, and compliance with Eskom’s Vehicle and Driver Safety Management Procedure. Uphold housekeeping, signage, and workplace order. Prohibit child labour and enforce zero-tolerance substance abuse policy (0% alcohol/drugs). Comply with COVID-19 policies, including risk assessments, PPE use, and National Disaster Management Act requirements. Follow Eskom’s SHEQ Policy, OHS specifications (e.g., 32-136, 32-520), and ISO 45001:2018 standards.
Financial Requirements
Source: SHE SPEC- platform.pdfItemise OHS costs in your bid, including: Training costs (e.g., working at heights, fall protection, Eskom Life-Saving Rules). Provision of PPE and safety equipment (e.g., fall arrest systems, face shields, insulated gloves). Safety file preparation and maintenance. Medical surveillance and annual fitness examinations for all employees. COVID-19-related costs (PPE, risk mitigation, compliance officer appointment) — note these are non-profit and subject to Eskom approval. Vehicle safety costs (inspections, maintenance, roadworthiness certificates). Ensure pricing is transparent, aligns with the scope of work, and includes all OHS-related expenditures. Maintain detailed financial records for audit purposes.
Compliance Requirements
Source: SHE SPEC- platform.pdfMandatory Compliance: Valid B-BBEE certificate (minimum Level 2 preferred). Registration with the Compensation Commissioner and a valid Letter of Good Standing (LoG), kept current throughout the contract. Compliance with the Occupational Health and Safety Act (OHS Act) and its regulations, including Section 37(2) agreement signed before work commencement. Adherence to Eskom’s SHEQ Policy (32-727) and OHS specifications (e.g., 32-136 Contractor Health and Safety Requirements, 32-520 Risk Assessment Procedure). Registration and compliance with relevant SANS standards (e.g., SANS 1186 for symbolic safety signs). National Environmental Management Act (NEMA) and other environmental legislation. National Road Traffic Act for vehicle safety and management. Compensation for Occupational Injuries and Diseases Act (COIDA). ISO 45001:2018 for occupational health and safety management systems. Statutory appointments (e.g., Health and Safety Representative, First Aider, Incident Investigator, Hazardous Chemical Substances Coordinator). Medical fitness certificates for all employees, renewed annually. COVID-19 compliance, including National Disaster Management Act requirements and appointment of a Compliance Officer. Prohibition of child labour as per the Constitution and Basic Conditions of Employment Act. Eskom-specific compliance: Life-Saving Rules, Substance Abuse Procedure (32-37), and Vehicle and Driver Safety Management Procedure (240-62946386).
Submission Guidelines
Source: Installation and operation of Suspended Platforms Technical Evaluation Strategy - Rev 1.pdfMandatory returnable documents for submission:
Note: Failure to submit these documents may result in disqualification.
Evaluation Criteria
Source: Installation and operation of Suspended Platforms Technical Evaluation Strategy - Rev 1.pdfTechnical evaluation threshold: Minimum weighted final score of 70% required to be considered technically compliant.
Scoring method:
Qualitative evaluation criteria (100% total weight):
Disqualifying risks:
Acceptable risks:
Technical Specifications
Source: Installation and operation of Suspended Platforms Technical Evaluation Strategy - Rev 1.pdfScope of work:
Areas of application:
Standards and compliance:
Critical requirements:
Compliance Requirements
Source: Installation and operation of Suspended Platforms Technical Evaluation Strategy - Rev 1.pdfMandatory compliance:
Submission Guidelines
Source: OHS requirements.pdfSubmit the following returnable documents: - Signed acknowledgement of Eskom's OHS legal and other requirements (Annexure B). - Health and Safety Plan addressing project/scope OHS risks, aligned with Eskom’s health and safety specifications. - Detailed OHS costing breakdown (not lump sum), based on the overall scope of work and risk assessment. - Baseline OHS Risk Assessment (BRA) with methodology. - Valid Letter of Good Standing (COIDA or equivalent). - OHS policy signed by CEO, compliant with OHS Act Section 7. - Proof of OHS competency (CVs, qualifications/certificates) for scope-specific risks.
Evaluation Criteria
Source: OHS requirements.pdfCore eligibility is contingent on passing the OHS evaluation. Key criteria: - Legal compliance: Signed OHS acknowledgement and CEO-signed OHS policy. - Financial compliance: Valid Letter of Good Standing (COIDA or equivalent). - Technical and managerial competency: Demonstrated via risk assessment, safety plan, and personnel qualifications for suspended platforms and mobile lifts in a power station environment. - Financial transparency: Detailed, scope-based costing for OHS elements.
Technical Specifications
Source: OHS requirements.pdfScope: Hiring, installation, and operation of suspended platforms and mobile lifts on an 'as and when' required basis for five years at Kriel Power Station. Requirements: - Must align with Eskom’s health and safety specifications. - Risk assessment and management for the scope of work must be provided.
Financial Requirements
Source: OHS requirements.pdfSubmit detailed OHS costing broken down by activity (not lump sum). Costing must be based on the overall scope of work and risk assessment, using the scope and BRA as guidelines.
Compliance Requirements
Source: OHS requirements.pdf