This interactive procurement analysis dashboard provides a comprehensive, AI-generated Document Analysis and structural compliance checklist for Tender cmlb04uth00dhuasocvbcuws4 ('PLACEMENT OF AUTOMATED MICROBIAL IDENTIFICATION PLATFORM FOR PUBLIC HEALTH LABORATORY GREEN POINT COMPLEX INCLUDING CONSUMABLES, REPAIRS, SERVICE AND MAINTENANCE FOR A PERIOD OF FIVE (5) YEARS.') issued by National Health Laboratory Service. This automated analysis covers mandatory verification records, Awarding Organisation Context (including Key Personnel), Source Evidence, and critical deadlines—outlining exactly 0 business days remaining before closing. While this public layout details core project criteria, authenticated users can access our full utility suite: run a Match Analysis and Eligibility Checker against your corporate profile, utilize the Tender Value Estimator, map milestones with the Auto Generation Preparation Timeline and Project Implementation Planner, create documents via Template Generators, receive AI Application Assistance, utilize Publisher Connect, and manage progress with Save & Export Tools and Important Reminders.
Province
Western Cape
Closing Date
27 February 2026 at 09:00
Estimated Value
Value not specified
Sign in or upgrade to see 7 key insights extracted from the document analysis — including submission guidelines, evaluation criteria, technical specifications, financial requirements, and compliance rules.
Unlock with a subscription or Action Pack →Source confidence
High source confidence
Official source
eTenders.gov.za
Documents found
1
Last checked
24 Jun 2026
AI status
Enhanced
This tender has strong source evidence, including source metadata and supporting tender information synced from the government tender portal.
Tenders SA is not the issuing authority. All tenders are automatically synced from the official government tender portal. Always confirm final submission details, closing dates, briefing sessions, eligibility requirements, and documents on the official government portal before applying.
Placement of automated microbial identification platform for public health laboratory green point complex including consumables, repairs, service and maintenance for a period of five (5) years.
Most bidders are rejected due to compliance gaps. Use our Readiness Engine to verify your status for this specific Supplies: Medical.
Check My Readiness2 key dates
Tender Published
5 February 2026 at 22:00
Tender was published
Tender Closing Date
27 February 2026 at 09:00
Final deadline for submission
162 items · 32 mandatory
The Division of Human Genetics uses of a Genetic Analyser for Sanger sequencing and fragment analyses. This
instrument uses capillary electrophoresis to separate polymerase chain reaction (PCR) fragments of different
lengths with high precision. In doing so, the laboratory is able to detect various point mutations, deletions and
insertions which are causative of various genetic conditions. The laboratory can also use the instrument for the
analysis of short tandem repeat polymorphisms which are useful in establishing relatedness, and chromosomal
copy number variation inpatients. The current instrument can process 24 samples in parallel without affecting
the running time of each sample, so that high-quality data can be used for high-throughput analysis. The
division runs about 80% of its tests on the genetic analyser per year. The current instrument was an outright
purchase and servicing the instrument is now via annual service contract deviations.
.
4 MANDATORY REQUIREMENTS
If a bidder does not comply fully with each of the mandatory requirements, it Shall be regarded as mandatory
non-performance/non-compliance and the bid Shall be disqualified. No “unanswered” questions will be
allowed. If a response to a question has been indicated as comply but not elaborated upon or substantiated it
shall be regarded as mandatory non- performance/non-compliance and the bid shall be disqualified.
Bidders shall provide full and accurate answers to the mandatory questions posed in this document, and,
where required, explicitly state either “Comply/Accept (with a “Yes”)” or “Do not comply/do not accept (with
a “No”)” regarding compliance to the requirements. Bidders must substantiate their responses to all
mandatory questions. PLEASE NOTE: If the response does not substantiate any of the points or requirements
in the body of the tender, it will be deemed to not comply, even if the ‘Comply’ field has been marked. Please
note: All documentation to substantiate the mandatory requirements has to be supplied.
TECHNICAL SUITABILITY: MANDATORY REQUIREMENTS
(NOTE: The bidder who fails to comply with the Mandatory Requirements WILL be disqualified).
Comply Do Not Comply
1. Sample Capacity: must be able to run and complete 240 samples during an 8-hour period
(i.e. 2 and half 96 well plates) with 24 samples per run.
Substantiation: Provide proof by means of brochure/specification. Failure to provide information will lead to
disqualification.
2. Must be capable of Sanger sequencing including Big Dye Terminator Chemistry. Comply Do Not Comply
Substantiation: Provide proof by means of brochure/specifications. Failure to provide information will lead to
disqualification.
3. Must be capable of Fragment analysis (Regular and HID, including STR’s, SNP’s, MLPA) Comply Do Not Comply
with multiplexing and dosage detection capabilities, data collection and analysis.
Substantiation: Provide proof by means of brochure/specifications. Failure to provide information will lead to
disqualification.
4. Must be compatible with a minimum of 50cm capillary array. Comply Do Not Comply
Confidential of 62
RFB208/25/26: Placement of 2 x Genetic Analysers CE (Capillary Electrophoresis) open system for Braamfontein-Genetic Department including
reagents, service and maintenance for a period of five (5) years.
Substantiation: Provide proof by means of brochure/specifications. Failure to provide information will lead to
disqualification.
5. Must be capable of 6 dye chemistry. Comply Do Not Comply
Substantiation: Provide proof by means of brochure/specifications/commitment letter. Failure to provide information
will lead to disqualification.
6. Must be open system in terms of plasticware and kits that can be run on the equipment Comply Do Not Comply
including, but not limited to: Applied Biosystems kits, custom fluorescently labelled primers,
Promega kits, Yourgene kits, Asuragen kits, MRC Holland kits, Qiagen kits or equivalent (be
able to add other suppliers’ kits as required) i.e. custom spectrals.
Substantiation: Provide proof by means of brochure/specification/commitment letter. Failure to provide information will
lead to disqualification.
7. Read Length required: Minimum 700bp for Sanger sequencing products and up to 1000bp Comply Do Not Comply
for Fragment Analysis. 1000bp sizing is not required, but visualization of products is. Sizing
for Fragment Analysis is required up to 600bp
Substantiation: Provide proof by means of brochure/specification. Failure to provide information will lead to
disqualification.
8. Software for analysis of DNA sequences as well as software for analysis of fragments. Comply Do Not Comply
Analysis to include amplicon sizing, peak height, peak area, dye separation, to be able to load
panels and bins for allele calling for kits from different suppliers for the duration of the
contract.
Substantiation: Provide proof by means of brochure/specification. Failure to provide information will lead to
disqualification.
Comply Do Not Comply
9. Must have automated amplicon separation with 1bp separation capability.
Substantiation: Provide proof by means of brochure/specification or commitment letter. Failure to provide information
will lead to disqualification.
10. Must have adjustable run conditions and protocols. Comply Do Not Comply
Substantiation: Provide proof by means of brochure/specification. Failure to provide information will lead to
disqualification.
Comply Do Not Comply
11. Instrument must be capable of interfacing with LIMS/Third party softwares.
Substantiation: Provide proof by means of brochure/specification/commitment letter. Failure to provide information will
lead to disqualification.
12. Must have a Reagent usage tracking /notification. Comply Do Not Comply
(Substantiation: Provide proof by means of brochure/specification/commitment letter. Failure to provide information
will lead to disqualification.
13. Must be able to interface with Barcoding system. Comply Do Not Comply
Substantiation: Provide proof by means of brochure/specification/commitment letter. Failure to provide information will
lead to disqualification.
Confidential of 62
RFB208/25/26: Placement of 2 x Genetic Analysers CE (Capillary Electrophoresis) open system for Braamfontein-Genetic Department including
reagents, service and maintenance for a period of five (5) years.
14. Must be able to export data to an external device and data must retrievable and Comply Do Not Comply
compatible to the lab PCs software (CSV, text files).
Substantiation: Provide proof by means of brochure/specification/commitment letter. Failure to provide information will
lead to disqualification.
5. Technical Functionality
5.1The bidder must complete in full all of the TECHNICAL FUNCTIONALITY requirements.
5.2 The bidder must provide a unique reference number (e.g. binder/folio, chapter, section, page) to locate
substantiating evidence in the bid response. During evaluation, NHLS reserves the right to treat substantiation evidence
that cannot be located in the bid response as “NOT COMPLY”.
Evaluation per requirement. The evaluation (scoring) of bidders’ responses to the requirements will be determined by
the completeness, relevance and accuracy of substantiating evidence.
Each TECHNICAL FUNCTIONALITY requirement will be evaluated using the following generic point scale:
Technical Functionality Requirements
The bidder must achieve a score of 75% to be eligible to proceed to the next stage of the evaluation.
Substantiation: Evidence can be provided in the brochure and/ or manuals and /or commitment letters.
Evaluation Criteria Score % Substantiate Reference
The analysis software should be able to calculate paternity and other kinship 15%
likelihood ratios.
Analysis software to calculate paternity and other kinship likelihood ratios to be
compatible with LAB workflow without the need for exporting data to other
software = 15%
Analysis software to calculate paternity and other kinship likelihood ratios to be
compatible with LAB workflow with exporting data to third party software = 10%
Software for calculating paternity and other kinship likelihood ratios not
compatible with lab workflow/No software = 0%
(Provide proof by means of specification/brochure).
Instrument related Reagent Loading should be Plug and Play: 20%
No manual intervention beyond loading a sachet = 20%.
Pippeting of reagents onto the instrument = 15%
Having to dilute/mix reagents prior to loading = 0%
(Provide proof by means of specification/brochure).
Confidential of 62
RFB208/25/26: Placement of 2 x Genetic Analysers CE (Capillary Electrophoresis) open system for Braamfontein-Genetic Department including
reagents, service and maintenance for a period of five (5) years.
Evaluation Criteria Score % Substantiate Reference
Duration of maintenance. 15%
Daily maintenance less than 5 minutes, Weekly and Monthly maintenance less
than 1 hour = 15%
Daily maintenance less than 5 minutes, Weekly and Monthly maintenance
between 1-2 hours = 10%
Daily maintenance up to 10 minutes, Weekly and Monthly maintenance up to 2
hours = 5%
Daily maintenance more than 10 minutes, Weekly and Monthly maintenance
more than 2 hours = 0%
(Provide proof by means of specification/brochure).
Spares/parts must be readily available. 15%
Available in approximately 6 hours = 15%
Available in approximately 24 hours = 10%
Available in approximately 48 hours =5%
(Provide proof by means of specification/brochure/ commitment letter).
Back-up Network associated Storage device on-site for storing DNA data from 10%
the instrument:
Provide Back-up data storage of 32TB = 10%
Provide Back-up data storage of 16TB = 5%
No Back-up data storage provided = 0%
(Provide proof by means of specification/brochure/ commitment letter).
Nucleic Acid Sequencing alignment software: 15%
Should be able to align unknown nucleic acid sequences with the reference
sequence and identify mismatches/conflicts = 15%
Not able to provide a Nucleic Acid Sequence alignment software = 0%
Provide proof by means of specification/brochure/ commitment letter).
Reagents usage management report: 10%
Capable of providing a historical breakdown of reagent usage, with lot numbers
and dates changed, as well as current and remaining usage = 10%
Provide only current and remaining usage = 5%
Provides no breakdown of current and remaining usage = 0%
TOTAL 100%
Confidential of 62
RFB208/25/26: Placement of 2 x Genetic Analysers CE (Capillary Electrophoresis) open system for Braamfontein-Genetic Department including
reagents, service and maintenance for a period of five (5) years.
Summary- The bidder needs to provide detailed brochure/ Specification confirming the above. The bid must achieve
score of 75% as illustrated above to be eligible to proceed to the next stage of the evaluation.
1. A threshold of 75% needs to be achieved to be considered for further evaluation.
2. The bid specification was compiled and approved by the Line of Business and the following is hereby confirmed:
• the Bid Specification document can be objectively evaluated using the evaluation criteria stated in the RFB
document; and
• the technical specifications are open and not written around a particular brand or product.
Confidential of 62
RFB208/25/26: Placement of 2 x Genetic Analysers CE (Capillary Electrophoresis) open system for Braamfontein-Genetic Department including
reagents, service and maintenance for a period of five (5) years.
No specific requirements found
The National Health Laboratory Service (NHLS) is a public entity that provides diagnostic laboratory services to South Africa's public health sector. Its procurement covers laboratory reagents, equipment, ICT systems, facilities management, and professional health services.
N/A
B-BBEE Level
—
Industry Sectors
—
Provinces
AI Document Analysis Stages
We refine every tender document through these stages so you can brief your team and prepare your bid with confidence. Anything marked as "in progress" will be upgraded automatically — no action required from you.
Unlock the full AI-extracted sections, compliance review, and bid-ready summaries from this tender's documents
Already subscribed or have a bundle? Sign in
RFB208_25-26_Bid Document_Reviewed v00.pdf
National Health Laboratory Service tender in Western Cape. Closing 2/27/2026. PLACEMENT OF AUTOMATED MICROBIAL IDENTIFICATION PLATFORM FOR PUBLIC HEALTH LABORATORY GREEN POINT COMPLEX INCLUDING CONSUMABLES, REPAIRS, SERVICE AND ...
Check if your company qualifies for this tender before you apply.
Organization
National Health Laboratory Service
Contact Person
Phillip Serage
Phone
064-880-5687
[email protected]
Address
1 Portswood Road - NHLS Old City Hospital Complex - Green Point Cape Town - 8000
27 February 2026 at 09:00
Location
Western Cape
Closing Date
27 February 2026 at 09:00
Organization
National Health Laboratory Service
Urgent: Closing Soon
This tender closes in less than 3 days
Mandatory Requirements
This tender has mandatory submission requirements
Are you a news editor or niche publisher? Embed this tender data directly on your site for free.
Get Embed CodeData conflicts
None detected
Median Estimate
R 158 234
Range
Based on 4 comparable awarded tenders. Companies with similar profiles typically bid near the median.