Airports company south africa (acsa) is seeking a service provider to execute and supervise fire system remedial works at cape town international airport for a 12-month period. The successful bidder must align with acsa's integrated environmental management policy, including maintaining an iso 14001:2015-based environmental management system and complying with environmental obligations.
Key Requirements
Must execute and supervise fire system remedial works at Cape Town International Airport for 12 months.
Must adhere to ACSA's Integrated Environmental Management Policy and maintain an ISO 14001:2015-based Environmental Management System.
Must conduct regular audits of the environmental system and monitor significant environmental aspects.
Must ensure all employees, contractors, and supply chain are aware of environmental requirements.
Must comply with relevant environmental legal obligations and report environmental performance indicators.
Must actively reduce energy, water, waste, and carbon footprint, and avoid pollution.
Must collaborate with ACSA and stakeholders to minimise environmental impact.
Tender for the appointment of a service provider for the execution & supervision of fire system remedial works for cape town international airports for period of twelve (12) months.
Briefing SessionCompulsory
Date & Time
Friday, 21 August 2026 - 12:00
Venue
Cape Town International Media Centre – Located inside the Terminal Building close to Int. arrivals
Important: Attendance at this briefing session is mandatory. Bids from suppliers who do not attend may be disqualified.
Requirements & Eligibility
Eligibility Criteria
A site inspection may take place after the compulsory briefing session. Important to note: IT is advised that the representative that will be attending the compulsory briefing session is directly involved in the compilation of the bid document submission. During the briefing session, we offer key instructions on the requirements that are to be observed when compiling your bid submission. IT would be in the bidding entities best interest to send a representative that will understand and action the key instructions given during the briefing session
Review in progress · 1 of 4 document being finalised
AI Document Analysis Stages
Document read. The full tender notice and its supporting documents are read end-to-end. Key sections, requirements, dates, and contact details are identified and pulled into a working summary you can act on.
Compliance review. The working summary is checked against South African procurement standards — PFMA, PPPFA, B-BBEE, CIDB, local content, and preferential procurement — so nothing critical is missed before you start your bid response.
Review in progress
The information shown on this card is preliminary. Our procurement team is currently finalising the submission guidelines, evaluation criteria, technical specifications, financial requirements, and compliance sections so you have a clean, bid-ready summary to work from. Document being finalised: Bid document Remedial Fire Protection Systems 2026.pdf. You don’t need to refresh — this page will pick up the updated review automatically.
DocumentBid document Remedial Fire Protection Systems 2026.pdfCompliance review in progress
Important Dates
20 Jul
2026
PUBLICATION
Tender Published
Tender was published
21 Aug
2026
DEADLINE
Closing Date
Tender closing date
Procurement Rules & Compliance ContextThis tender may be governed by South African public procurement rules covering fairness, transparency, preferential procurement, anti-corruption, administrative justice and access to information.
7 rules
These references help suppliers understand the public-procurement framework around this opportunity. They are generated from the tender category, issuing organisation type and procurement context.
Core procurement rules
These rules commonly apply to South African public-sector procurement.
7
Broad-Based Black Economic Empowerment Act (B-BBEE Act)
Act 53 of 2003
high
Provides the empowerment-compliance context often used in public-sector supplier evaluation.
Relevant because this is a South African public-sector procurement opportunity.
Constitution of the Republic of South Africa, 1996 – Section 217
Act 108 of 1996 (s217)
high
This is general procurement context, not legal advice. Always verify requirements in the official tender documents and issuing authority notices.
This document contains the Integrated Environmental Management Policy Statement for Airports Company South Africa (ACSA), which outlines the company's commitment to environmental stewardship. It is part of a tender for appointing a service provider to execute and supervise fire system remedial works at Cape Town International Airport for a 12-month period. The policy defines ACSA's environmental management framework, which the successful service provider will be required to operate within.
Bid document Remedial Fire Protection Systems 2026.pdf
Tender for appointment of a service provider to execute and supervise fire system remedial works at Cape Town International Airport for 12 months. The contract involves design, assessment, and supervision of fire protection systems with strict compliance and evaluation stages.
Tender for a 12-month contract to execute and supervise fire system remedial works at Cape Town International Airport (Terminals 1, 2, CTB, T5, and Cargo Building) using the NEC3 Engineering & Construction Contract (Option B).
Tender for a service provider to execute and supervise fire system remedial works at Cape Town International Airport for 12 months. Evaluation uses the 80/20 preference point system.
Win ACSA tenders with AI Matching Engine, airport-infrastructure intelligence, compliance analysis, and application support for aviation operations.
Similar Tenders
Matched by category & region
Supplier Readiness Hub
Free guidance to prepare before you bid
Not sure if your business is ready for this tender? Check CSD, CIDB, and B-BBEE requirements, run a readiness assessment, and move from opportunity to submission.
Based on 14 comparable awarded tenders. Companies with similar profiles typically bid near the median.
* Estimates are based on historical data and do not guarantee actual award values.
Bid-ready summary. The submission guidelines, evaluation criteria, technical, financial, and compliance sections are refined into professional, easy-to-scan prose. This is the final version you can rely on when preparing your bid or briefing your team.
We refine every tender document through these stages so you can brief your team and prepare your bid with confidence. Anything marked as "in progress" will be upgraded automatically — no action required from you.
Document read
Compliance review
Bid-ready summary
Important Dates
Source: Bid document Remedial Fire Protection Systems 2026.pdf (RFP)
Tender document available: 20 July 2026 (free download from etenders.gov.za and ACSA Tender Bulletin).
Compulsory briefing session: 28 July 2026 at 10:00 for 10:30, Cape Town International Media Centre (inside terminal near International Arrivals).
Non-compulsory site inspection: On request, after briefing; requirements TBA.
Enquiries closing date: 4 August 2026, close of business (also stated as 6 August 2026 in Tender Data – note discrepancy).
Tender closing date: 21 August 2026 at 12:00 midday.
Tender validity period: 84 days (12 weeks) from closing date.
Contact Information
Source: Bid document Remedial Fire Protection Systems 2026.pdf (RFP)
Employer's agent: Graham Mitchell (ACSA SCM Representative).
All communication during tender period must be directed to ACSA's Supply Chain Management Department, not the principal agent.
Physical submission address: Tender Box – Procurement Department, Southern Office Block Building – Ground Floor, Cape Town International Airport, Matroosfontein.
No telephone numbers provided for contacts.
Submission Guidelines
Source: Bid document Remedial Fire Protection Systems 2026.pdf (RFP)
Submit one original and one copy in printed format, plus an electronic copy on a USB flash drive.
Seal bids in clearly marked envelopes/package indicating 'Original' and 'Copy', with tenderer's name, contact details, CSD MAAA number, tender reference CTIA7438/2024/RFP, and description.
Deliver to: Tender Box – Procurement Department, Southern Office Block Building – Ground Floor, Cape Town International Airport, Matroosfontein.
Submission deadline: 21 August 2026 at 12:00 midday (South African time). Late bids will not be accepted.
Submit during working hours Monday–Friday; after-hours submissions must be confirmed via email.
Complete the Bid Submission Register placed next to the tender box.
Use only the official tender documents; do not retype or alter them. All signatories must initial any corrections.
Telephonic, telegraphic, telex, fax, or emailed tenders will not be accepted.
Mandatory returnables include fully completed and signed Form of Offer and Acceptance (C1.1) and all SBD returnables.
Mark packages with bidder's return address for return of late bids.
If using a third-party courier, ensure they complete the Bid Submission Register.
Bids must be valid for 84 days (12 weeks) from closing date.
Evaluation Criteria
Source: Bid document Remedial Fire Protection Systems 2026.pdf (RFP)
Staged evaluation: Stage 1 – Test for responsiveness; Stage 2 – Mandatory criteria; Stage 3 – Functionality; Stage 4 – Price and preference; Stage 5 – Post-tender negotiations/security vetting if required.
Mandatory criteria (Stage 2):
Attendance of compulsory briefing session.
Fully completed and signed Form of Offer and Acceptance (C1.1).
Active CIDB contractor grading of 6SF or higher.
Functionality (Stage 3) – total 100 points, minimum threshold 55 points to proceed:
Company's previous experience (30 points): Up to 3 reference letters for fire protection/detection design (5 points each) and up to 3 for fire rational assessments (5 points each), or up to 3 letters showing both (10 points each). Each referenced project must have contract value ≥ R500,000. Letters must include company name, scope, nature, and contract value.
Human resource – staff experience (70 points):
Fire Engineer (15): NQF level 6 Mechanical Engineering (0); NQF level 6 + ECSA Pr Techni (3.75); NQF level 7 + ECSA Pr Eng/Pr Tech (7.5). Experience: min 2 years post-ECSA with fire protection/rational assessments (3.75); above 3 years (7.5).
Mechanical Engineer (15): NQF level 6 (0); NQF level 6 + ECSA Pr Techni (3.75); NQF level 7 + ECSA Pr Eng/Pr Tech (7.5). Experience: min 2 years post-ECSA with HVAC (3.75); above 3 years (7.5).
Electrical Engineer (15): NQF level 6 (0); NQF level 6 + ECSA Pr Techni (3.75); NQF level 7 + ECSA Pr Eng/Pr Tech (7.5). Experience: min 2 years post-ECSA with fire detection and pump automation (3.75); above 3 years (7.5).
Architect (15): NQF level 6 (0); NQF level 6 + SACAP PrArchT (3.75); NQF level 7 + SACAP PrSArchT/Pr Arch (7.5). Experience: min 2 years post-SACAP in design/detailing/documentation (3.75); above 3 years (7.5).
Site Supervisor (10): NQF level 2 with SAQCC Fire registration 1475 (2.5); NQF level 3 with SAQCC Fire registration 1475 (5). Experience: min 2 years post-SAQC supervising maintenance of pumps/fire sprinklers (2.5); above 3 years (5).
All qualifications must be SAQA-accredited; foreign/technical qualifications must be SAQA/CETA/SETA approved.
Price and preference (Stage 4): 80/20 preference point system (PPPFA). Price formula: Ps = 80(1 - (Pt - Pmin)/Pmin). Preference points (max 20): B-BBEE status level 1 (5), level 2 (4.5), level 3 (4), level 4 (3), level 5 (2), level 6 (0.5), level 7 (0.3), level 8 (0.1); black youth majority-owned (5); black women majority-owned (5); entity located in provincial/municipal/district where services procured (5). Non-compliant contributor scores 0.
Proof required for preference points: original/certified sworn affidavit (construction) or valid B-BBEE certificate from SANAS-accredited agency with report; for JV, consolidated certificate.
Post-tender negotiations and security vetting may be carried out if required.
Contract awarded to highest ranked tenderer after all stages.
Technical Specifications
Source: Bid document Remedial Fire Protection Systems 2026.pdf (RFP)
Scope: Execution and supervision of fire system remedial works at Cape Town International Airport for a period of 12 months.
Mandatory contractor requirement: Active CIDB contractor grading 6SF or higher.
Key personnel requirements (with detailed scoring in functionality evaluation):
Fire Engineer: NQF level 6/7 Mechanical Engineering with ECSA registration (Pr Techni/Pr Eng/Pr Tech) and fire protection experience including rational assessments/designs.
Mechanical Engineer: NQF level 6/7 Mechanical Engineering with ECSA registration and HVAC experience.
Electrical Engineer: NQF level 6/7 Electrical Engineering with ECSA registration and fire detection/pump automation experience.
Architect: NQF level 6/7 Architecture with SACAP registration (PrArchT/PrSArchT/Pr Arch) and design/detailing/documentation experience.
Site Supervisor: NQF level 2/3 with SAQCC Fire registration 1475 and experience supervising maintenance of pumps and fire sprinklers.
Site safety protocol: Must wear specified PPE (lime green retro-reflective jacket with reflective tape, safety shoes) and bring original or certified copy of ID (not driver's license) for airside access.
Contract includes annexures: ACSA Generic OHS Specification, Baseline HIRA, OHS Agreement, Environmental Terms & Conditions, Construction Environmental Management Plan, Contractor's Installation Conditions & House Rules, POPIA Agreement, and B-BBEE programme.
Contract is based on NEC3 ECC (Option B pricing).
Alternative bids will not be considered.
Contract price adjustments not applicable; prices fixed for duration.
Financial Requirements
Source: Bid document Remedial Fire Protection Systems 2026.pdf (RFP)
Pricing is fixed for the contract duration; no contract price adjustments or foreign fluctuations apply.
Tender amount must include VAT and match the combined C1.1 Offer and Acceptance in the NEC3 ECC contract.
The successful bidder must provide proof of insurance on award (contract will not be signed without valid insurance).
No bid bond or advance payment guarantee is specified in the extracted text.
Tenderer bears all costs of preparing and submitting the tender.
If tender validity lapses before evaluation, employer reserves right to review price based on CPI.
Compliance Requirements
Source: Bid document Remedial Fire Protection Systems 2026.pdf (RFP)
Mandatory: Active CIDB contractor grading 6SF or higher.
Tax compliance: Submit SARS Tax Compliance Status PIN or CSD number; joint ventures/consortiums/sub-contractors must submit for each party. If no TCS PIN, provide CSD number.
B-BBEE: Must provide proof (B-BBEE certificate from SANAS-accredited agency or sworn affidavit) to score preference points; JV must provide consolidated certificate.
COIDA: Valid letter of good standing with Workers Compensation Commissioner (Department of Labour, FEM or RMA) required before contract signing; nature of business must be relevant to tender.
Entities in service of the state (or with directors/members in service of state) are disqualified.
Foreign suppliers must answer questionnaire; if no RSA presence/income/tax liability, TCS PIN not required.
Must not be insolvent, in receivership, under business rescue, bankrupt, or being wound up.
Must have legal capacity to contract and be free of conflicts of interest.
Must not be under any restriction to do business with employer.
Proof of authority required for signatory (e.g., company resolution).
DocumentCTIA ACSA AD.pdfReview complete
Description
Source: CTIA ACSA AD.pdf
Scope: Appointment of a service provider for execution and supervision of fire system remedial works at Cape Town International Airport.
Contract duration: Twelve (12) months.
Important Dates
Source: CTIA ACSA AD.pdf (RFP)
Compulsory site briefing session: 28 July 2026 at 10:00 (until 10:30). Venue: Media Centre, Cape Town International Airport (close to International Arrivals).
Clarification enquiries deadline: 4 August 2026, close of business.
Bid closing date: Friday 21 August 2026 at 12:00 midday.
Uses the 80/20 preference point system: 80 points for price, 20 points for B-BBEE recognition.
B-BBEE status must be proven using DTI criteria only.
Refer to the B-BBEE Preference Score Table in the bid document for scoring details.
Technical Specifications
Source: CTIA ACSA AD.pdf (RFP)
Scope: Execution and supervision of fire system remedial works at Cape Town International Airport.
Contract period: Twelve (12) months.
The service provider must be capable of executing and supervising remedial works on fire systems, ensuring compliance with relevant standards and specifications.
Compliance Requirements
Source: CTIA ACSA AD.pdf (RFP)
Tax compliance: No tender will be awarded to any person whose tax matters have not been declared in order by SARS.
CIDB: Only active CIDB contractor grading of 6SF or higher is eligible.
B-BBEE: Must comply with DTI criteria and provide proof of B-BBEE status. Only DTI criteria accepted.
Transformation imperatives: ACSA subscribes to National Transformation Imperatives and B-BBEE objectives, including skills development, enterprise development, and localization.
Attendance at the compulsory briefing session is mandatory.
Refer to Section 6 of the bid document for the complete list of mandatory returnable documents.
B-BBEE Requirements
Source: CTIA ACSA AD.pdf (RFP)
ACSA subscribes to National Transformation Imperatives and B-BBEE objectives.
Only DTI criteria are accepted as proof of B-BBEE status.
Transformation imperatives include skills development, enterprise development, and localization.
Refer to the B-BBEE Preference Score Table in the bid document.
Requirements
Source: CTIA ACSA AD.pdf (RFP)
Tax compliance with SARS is mandatory for award.
Only active CIDB contractor grading 6SF or higher is eligible.
Attendance at the compulsory briefing session is required.
Refer to section 6 of the bid document for mandatory returnable documents.
Section
Source: CTIA ACSA AD.pdf
Evaluation follows a six-stage process: responsiveness, mandatory requirements, functionality/technical, price and preference, post-tender negotiations, and security vetting.
Uses the 80/20 preference point system.
Refer to the B-BBEE Preference Score Table in the bid document.
The Integrated Environmental Management Policy applies to Airports Company South Africa SOC Limited (ACSA) infrastructure.
It covers the geographical areas where ACSA operates its aeronautical business of running and developing airports.
The scope centres around nine airports and the Corporate Office.
It includes associated employees, stakeholders, service providers, and contractors.
Evaluation Criteria
Source: T010P EMS Policy Statement .pdf (unknown)
The document does not detail specific technical or financial pre-qualification criteria in this excerpt.
A fundamental eligibility criterion is the service provider's ability and commitment to fully integrate with and adhere to ACSA's Environmental Management System as described in the policy statement.
The provider must operate in a manner consistent with the policy's objectives and requirements.
Technical Specifications
Source: T010P EMS Policy Statement .pdf (unknown)
The tender involves the execution and supervision of fire system remedial works at Cape Town International Airport.
The service provider must operate within Airports Company South Africa SOC Limited (ACSA) infrastructure and geographical areas.
The scope includes ACSA's aeronautical business of running and developing airports across nine airports and the Corporate Office.
The service provider must align with ACSA's Integrated Environmental Management Policy.
Maintain an Environmental Management System based on ISO 14001:2015.
Conduct regular audits of the environmental system to ensure adequacy and effectiveness.
Monitor and measure significant environmental aspects of airport activities and operations.
Set and review environmental objectives and targets.
Ensure all employees, operators, tenants, service providers, contractors, and supply chain within the system are aware of environmental aspects and system requirements.
Report environmental performance indicators in the integrated annual report.
Continually improve environmental performance.
Seek opportunities to reduce aircraft noise impact by engaging with industry stakeholders.
Monitor aircraft noise at Cape Town International, King Shaka International, and O R Tambo International Airports in accordance with SACAA requirements.
Actively seek opportunities to reduce energy consumption from non-renewable sources.
Measure the carbon footprint at all airports and actively seek opportunities to reduce it.
Monitor air quality at Cape Town International, King Shaka International, and O R Tambo International Airports per SACAA requirements.
Actively seek opportunities to reduce water consumption.
Avoid pollution of storm water and/or groundwater from airport operations.
Ensure all waste is minimised, reduced, re-used, or recycled.
Conserve biodiversity where feasible on ACSA property.
Collaborate with surrounding communities to minimise environmental impact.
Comply with relevant environmental legal obligations.
Where ACSA does not directly control impacts, work in partnership with operators, contractors, tenants, service providers, and supply chain management to improve performance.
The policy is reviewed by management every three years and is available upon request.
Environmental
Source: T010P EMS Policy Statement .pdf
The Integrated Environmental Management Policy statement shall be reviewed by management every three years.
It shall be made available to any interested parties upon request.
DocumentNEC Contract Fire Remedial Work.pdfReview complete
Description
Source: NEC Contract Fire Remedial Work.pdf
Appointment of a service provider for execution and supervision of fire system remedial works at Cape Town International Airport.
Contract duration: 12 months.
Site boundaries include Terminal Buildings (T1, T2, CTB, T5) and Cargo Building.
Works Information is in Part C3 Scope of Work; Site Information is in Part C4.
Important Dates
Source: NEC Contract Fire Remedial Work.pdf (RFP)
Closing date: 21 August 2026 at 12:00.
Contract start date: upon signing by ACSA.
Completion date: 12 months from contract start date.
Programme submission: within two weeks of contract start date.
Programme updates: at intervals no longer than two weeks.
Defects date: 52 weeks after completion of the works.
Assessment interval for payments: every four weeks, on the 15th day of each month.
Contact Information
Source: NEC Contract Fire Remedial Work.pdf (RFP)
Project Manager: Vuyolwethu Ncedana & Ronald Thanjekwayo, tel 021 937 1200, email TBC.
Supervisor: Khathulo Rabambi, tel 021 937 1200, email TBC.
Address: Airports Company South Africa SOC Limited, Cape Town International Airport, Private Bag X9002, Cape Town, 7525.
Submission Guidelines
Source: NEC Contract Fire Remedial Work.pdf (RFP)
Submit the Offer using the Form of Offer and Acceptance (C1.1).
The tenderer must sign the Offer signature block and include CIDB registration number.
Return one copy of the signed Form of Offer and Acceptance including any Schedule of Deviations to the Employer.
Ensure all required securities, bonds, guarantees, and proof of insurance are delivered within two weeks after receiving the signed agreement.
Failure to provide required documentation may constitute repudiation of the agreement.
Covering letters must not be included in the final contract document; deviations must be recorded in the Schedule of Deviations.
Returnable Documents
Source: NEC Contract Fire Remedial Work.pdf (RFP)
Form of Offer and Acceptance with signatures, names, capacities, and CIDB registration number.
Must provide proof of required insurance coverage.
Key personnel must have specified qualifications and experience.
Must comply with South African law and contract language (English).
Joint ventures must declare joint and several liability.
Technical Specifications
Source: NEC Contract Fire Remedial Work.pdf (RFP)
Scope: Execution and supervision of fire system remedial works at Cape Town International Airport terminals (T1, T2, CTB, T5) and cargo building for 12 months.
Key deliverables: Architectural survey and development plans, detailed hydraulic design for ICV sprinkler system, ICV jockey pump automation system, smoke ventilation extraction system, council submissions, and as-built drawings.
Required key personnel: Fire Engineer, Architect, Mechanical Engineer, Electrical Engineer, Site Supervisor (SAQCC Fire Registered -1475).
Design outputs must be in AutoCAD (DWG) and PDF formats, submitted to local authority for approval.
Works Information is detailed in Part C3 Scope of Work and referenced drawings.
Contractor must produce as-built drawings, test certifications, and ensure all designs meet specified standards.
Works must be fit for intended purpose as per Z2.1.
All developed drawings must be submitted to local authority for approval.
Methodology
Source: NEC Contract Fire Remedial Work.pdf (RFP)
Architectural survey to verify elements, dimensions, walls, doors, partitions, and capture deviations.
Produce AutoCAD (DWG) and PDF drawings for all engineering disciplines.
Detailed hydraulic design for ICV sprinkler system with test certification.
Design ICV jockey pump automation system including panel, electrical works, integration, cabling.
Design smoke ventilation extraction system including panel, electrical works, integration, cabling.
Submit all drawings to local authority for approval.
Experience & Qualifications
Source: NEC Contract Fire Remedial Work.pdf
Key personnel required: Fire Engineer, Architect, Mechanical Engineer, Electrical Engineer, Site Supervisor (SAQCC Fire Registered -1475).
CVs for key persons must be appended to the tender schedule.
Contractor must have experience in architectural surveys, hydraulic design, automation systems, and smoke ventilation design.
Pricing Schedule
Source: NEC Contract Fire Remedial Work.pdf
Pricing based on bill of quantities (Part C2).
Tenderer must provide tendered total of Prices (exclusive of VAT).
Hourly rates for design personnel (Professional Architect, Fire Engineer, Mechanical Engineer, Electrical Engineer, Draughtsman) required.
Percentages for people overheads and design overheads must be specified.
Equipment rates and adjustments based on published list.
Financial Requirements
Source: NEC Contract Fire Remedial Work.pdf (RFP)
Contract uses NEC3 Option B: Priced contract with bill of quantities.
Tenderer must provide the tendered total of Prices (exclusive of VAT) in figures and words.
Pricing data includes bill of quantities (Part C2), hourly rates for design personnel, percentages for people overheads, design overheads, and equipment rates.
Payment terms: Payments made every four weeks; interest on late payments based on Nedbank prime rate.
Retention: 5% of contract value (2.5% released at completion, 2.5% at end of defects liability period).
Performance bond required as per Option X13.
Delay damages: 2.5% up to maximum 10% of price at completion.
Low performance damages specified for delays and defects.
Hourly rates for design personnel (Professional Architect, Fire Engineer, Mechanical Engineer, Electrical Engineer, Draughtsman) required.
Percentages for people overheads and design overheads must be specified.
Equipment rates and adjustments based on published list.
Compliance Requirements
Source: NEC Contract Fire Remedial Work.pdf (RFP)
Aviation liability insurance required: R100,000 indemnity limit for landside works; R300,000 for airside works (airside clause applies if project covers both).
Proof of insurance must be submitted to ACSA before work starts and annually thereafter.
Contractor must ensure subcontractors are aware of and comply with insurance clauses.
CIDB registration number must be provided in the Offer.
Compliance with South African law, including Prevention and Combating of Corrupt Activities Act.
No specific B-BBEE, tax clearance, or CSD requirements are detailed in the provided text.
Contractor’s staff must complete ACSA training requirements (e.g., AVOP, Security Awareness Training, Airside Induction Training, PARTAC).
Safety File must be approved by the client before work starts.
Contractor must manage risks including site access approvals, police clearance, and tie-in with existing infrastructure.
Contractual Terms
Source: NEC Contract Fire Remedial Work.pdf
Contract governed by NEC3 Engineering and Construction Contract (April 2013) with Option B, W1, X2, X7, X16, X17, X18, and additional Z clauses.
Law of contract: Republic of South Africa. Language: English.
Defects correction period: 2 weeks (1 week for water leaks or electrical/mechanical faults).
Delay damages: 2.5% up to 10% of price at completion.
Low performance damages apply for delays, commissioning delays, failure to maintain SANS 10400 standards, and failure to correct defects.
Retention: 5% of contract value.
Limitation of liability clauses specify caps on contractor’s liability for indirect loss, property damage, and defects.
Additional clauses cover ethics, confidentiality, intellectual property, dispute resolution (adjudication and arbitration), and employer step-in rights.
Insurance requirements detailed in Annexure D.
Requirements
Source: NEC Contract Fire Remedial Work.pdf (RFP)
Tenderer accepts Conditions of Tender by submitting the Offer.
Contractor must comply with all contract terms and conditions.
Sets the constitutional standard for fair, equitable, transparent, competitive and cost-effective public procurement.
Relevant because this is a South African public-sector procurement opportunity.
Cape Town International Airport - Matroosfontein - CITY OF CAPE TOWN - 8000
Document-Backed
Source Snapshot Available
AI Enhanced
Source confidence
High source confidence
Official source
eTenders.gov.za
Documents found
4
Last checked
04 Aug 2026
AI status
Enhanced
Data conflicts
None detected
This tender has strong source evidence, including source metadata and supporting tender information synced from the government tender portal.
Tenders SA is not the issuing authority. All tenders are automatically synced from the official government tender portal. Always confirm final submission details, closing dates, briefing sessions, eligibility requirements, and documents on the official government portal before applying.