Tender Type
Expression of interest
Delivery Location
Electronic submission via Eskom E- tendering portal. - VARIOUS - Bloemfontein - 9301
Organization Type
GOVERNMENT
Published
04 Sept 2026
OCDS Reference
ocds-9t57fa-169070
ESKOM distribution invites expressions of interest for the supply and support of hitachi and ge (formerly alstom) protection, control and substation automation equipment, including switchgear panels, gateways, and associated spares, over a four-year period. The contract requires bidders to sustain eskom's existing scheme designsasi&
Closing / Response Date: 02 September 2026 (via Eskom e-Tendering portal; no hard copies accepted).
Non-compulsory clarification meeting (MS Teams): 10 September 2026 at 09H30 – register by 8 September 2026.
Must confirm capability to design, assemble, test and support the listed Hitachi/GE protection schemes and swing frame cabinets per the drawings in Section 5.4.
Must complete the schedules indicating which schemes (P1–P16) and quantities can be manufactured, supplied, supported and delivered within 4 years (and meet delivery lead times).
Must provide capability, skills, facilities and logistics information and confirm capacity to undertake the contract.
Must provide per-item pricing for each of the listed scheme types, panel types, junction boxes and swing frame cabinets, including full cost breakdowns.
Must confirm technical compliance with Eskom’s specifications (including drawing numbers) and identify any alternatives requiring deviation.
Complete the required returnable schedules including the CIBD (Certificate of Independent Bid Determination), E-tender declaration, and company/authority details.
Non-compulsory clarification meeting via MS Teams on 10 September 2026 – attendance recommended.
All correspondence and clarifications: [email protected] (051 404 2057).
Bidders must register on the SAPS Vendor/Supplier database and be able to submit on the E-Tender Portal.
Continue with tenders sharing this issuer, category, or province.
Return to this tender’s issuing organisation, province, or category.
Continue with tenders sharing this issuer, category, or province.
Date & Time
Wednesday, 30 September 2026 - 10:00
Venue
MS Teams - Meeting ID: 353904994610185
Expression of interest
Electronic submission via Eskom E- tendering portal. - VARIOUS - Bloemfontein - 9301
Tenders in this industry often require registration with these bodies.
Recommended Certifications
Having these can improve your winning chances: Good Manufacturing Practice (GMP), SABS Product Certification, NRCS Certification
AI Document Analysis Stages
Description
Source: Annexure A - Detailed Scope of Work.pdf04 Sept
2026
Tender Published
Tender was published
30 Sept
2026
Closing Date
Tender closing date
These references help suppliers understand the public-procurement framework around this opportunity. They are generated from the tender category, issuing organisation type and procurement context.
These rules commonly apply to South African public-sector procurement.
Act 53 of 2003
Provides the empowerment-compliance context often used in public-sector supplier evaluation.
Relevant because this is a South African public-sector procurement opportunity.
Act 108 of 1996 (s217)
This is general procurement context, not legal advice. Always verify requirements in the official tender documents and issuing authority notices.
Annexure B - Detailed Technical Evaluation Criteria.pdf
Analysis completed but response format was invalid
E3269DXGOUR - EOI - Protection Schemes - Reissue.pdf
Eskom Distribution is seeking expressions of interest from suppliers capable of engineering, manufacturing, supplying, testing, delivering, supporting and, where required, installing its previously developed range of Protection, Control and Substation Automation schemes, predominantly based on Hitachi (Pty) Ltd and IST (GE) products, including swing frame panels and PIU junction boxes, over a contract period of up to four years. The design intent, system architecture, brand and types of IEDs must be sustained, and suppliers must demonstrate the ability to reproduce and support the approved schemes without adversely affecting functionality, performance, interoperability, safety, reliability or compatibility with Eskom's installed base.
Annexure A - Detailed Scope of Work.pdf
Eskom Distribution is seeking expressions of interest for a contract to engineer, supply, train and support a previously developed range of protection, control and substation automation schemes, predominantly based on Hitachi and IST products, including swing frame cabinets and PIU junction boxes, over a period of up to four years. The contract requires sustaining the previous design intent, including system architecture, IED brands and types, guarantees, training and product support.
To download these documents and access AI-powered analysis, visit the main tender page.
Win Eskom tenders with AI Tender Matching, technical document analysis, compliance scoring, and structured bid support for energy and engineering contracts.
Matched by category & region
Free guidance to prepare before you bid
Not sure if your business is ready for this tender? Check CSD, CIDB, and B-BBEE requirements, run a readiness assessment, and move from opportunity to submission.
Open Supplier Readiness HubWe refine every tender document through these stages so you can brief your team and prepare your bid with confidence. Anything marked as "in progress" will be upgraded automatically — no action required from you.
Eskom intends to establish a contract for the engineering, supply, training, and support of protection and automation spares. The scope includes reviewing and supplying spares for Hitachi and IST solutions, including protection relays, IEDs, communication modules, power modules, electronic modules, switches, test blocks, covers, and circuit breakers. The contract is effective from 21 October 2025 to October 2028.
Important Dates
Source: Annexure A - Detailed Scope of Work.pdf (unknown){"closingDate":"21 October 2025"}
Evaluation Criteria
Source: Annexure A - Detailed Scope of Work.pdf (unknown)Bidders must sign a Non-Disclosure Agreement (NDA) to access design drawings. The document does not specify other eligibility criteria such as CSD registration, tax clearance, B-BBEE level, or CIDB grading.
Technical Specifications
Source: Annexure A - Detailed Scope of Work.pdf (unknown)Effective Date 21 October 2025
Review Date October 2028
Eskom Holdings SOC Ltd (“Eskom”) intends to initiate the commercial process to establish a contract for
the engineering, supply, training and support of a previously developed range of approved Protection,
Control and Substation Automation Schemes (predominantly based on the GE and Hitachi protection
relays) including the swing frame cabinets and PIU junction boxes to house these schemes, to Eskom
Distribution over a period of up to four (4) years as per the drawings listed in Table 1 below. Note that
the exact part and type numbers are listed in the respective drawings.
It is Eskom’s expectation that the previous design intent will be sustained, in terms of the overall system
architecture, functionality, brand and types of IEDs utilised (including part and type numbers), guarantees
and the provision of product support. The design details of the previously developed and approved
schemes and swing frame cabinets are captured in the engineering drawings and base configurations
which can be requested from Eskom and will be supplied (pdf’s) subject to signature of a Non-Disclosure
Agreement. These drawings will assist in understanding the scope.
It is Eskom’s intention to now re-establish these supply contracts with the already developed solutions.
The scope of work entails but not limited to the following:
be shared once a Non-Disclosure Agreement is signed). The list of scheme designs is provided
below.
deemed necessary over the duration of the contract,
requirements,
for Eskom Distribution, as and when required, over a period of up to four (4) years,
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
Table 1: List of previously designed schemes with associated drawing numbers
Supplier drawings, the latest revision accepted by both parties, relating to metalwork, physical
construction and panel and IED labelling shall be applicable.
No Drawing Description Drawing Reference Number and Revision
Hitachi Solution
Protection
5FZD32x0 D-DT-15011 - 15015_Rev 1
5FZD39x0 D-DT-15009 - 15010_Rev 2
5JB3100 D-DT-15900_Rev 0 & D-DT-5415
5TM3100 D-DT-15207_Rev 0
5JB3200 D-DT-15901_Rev 0 & D-DT-5416
5TM3200 D-DT-15210_Rev 2
5TC3200 D-DT-15302_Rev 1
5CF3100 D-DT-15408_Rev 2
5CF3150 D-DT-15411_Rev 2
5BS3100 D-DT-15409_Rev 2
5BS3150 D-DT-15412_Rev 2
5VT3100_5CPAT 3100 D-DT-15410_Rev 2
5VT3150_5CPAT 3150 D-DT-15413_Rev 2
5RF3100 and 5BC3100 D-DT-15407_Rev 2
5EG3100 D-DT-15503_Rev 0
5BP3500 and 5BP3700 D-DT-15608-15609_Rev 0
5BZ3600 D-DT-15607_Rev 0
5BZ3800 D-DT-15606_Rev 0
5BZ3900 D-DT-15605_Rev 0
Automation
5AGW3100 D-DT-15950_Rev 3
5AGW3200 D-DT-15951_Rev 2
5AGW3300 D-DT-15952_Rev 2
No Drawing Description Drawing Reference Number and Revision
IST Solution
5FZD5820 D-DT-15016_Rev 1
5FZD5840 D-DT-15017_Rev 1
5FZD5900 D-DT-15014_Rev 1
5FZD5920 D-DT-15012_Rev 1
5FZD5940 D-DT-15013_Rev 1
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
6 5JB5100 D-DT-15902_Rev 1 & D-DT-5417
5TM5100 D-DT-15208_Rev 1
5JB5200 D-DT-15903_Rev 1 & D-DT-5418
5TM5200 D-DT-15209_Rev 2
5TC5200 D-DT-15302_Rev 0
5CF5100 D-DT-15415_Rev 1
5CF5150 D-DT-15418_Rev 1
5BS5100 D-DT-15416_Rev 1
5BS5150 D-DT-15419_Rev 1
5VT5100 D-DT-15417_Rev 1
5VT5150 D-DT-15420_Rev 1
5RF5100 D-DT-15414_Rev 1
5BP5100 D-DT-15614_Rev 1
5BP5150 D-DT-15615_Rev 1
5BP5200 D-DT-15616_Rev 1
5BZ5600 D-DT-15613_Rev 1
5BZ5800 D-DT-15612_Rev 1
5BZ5900 D-DT-15611_Rev 1
5BC-5100 D-DT-15505_Rev 1
5EG-5100 D-DT-15506_Rev 1
Automation
5AGW5100 D-DT-15953_Rev 4
5AGW5200 D-DT-15954_Rev 5
No Drawing Description Drawing Reference Number and Revision
Swing Frames and Gateway Panels
Sheet 1_Rev 6
Sheet 2 _Rev 5
Sheet 3 _Rev 5
Sheet 4 _Rev 4
Sheet 5 _Rev 4
Sheet 6 _Rev 3
(600 x 600 x 1850/2200/2400)
Metering Equipment cabinet (600 x 600 x 2400) D-DT-5421 Sheet 1-3_Rev 0
Telecontrol Equipment cabinet (600 x 600 x 2400) D-DT-5418 Sheet 1-3_Rev 0
Internal Swing Frame Equipment cabinet (800 x 600 D-DT-5417 Sheet 0-1_Rev 0
x 2400)
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
x 2400)
x 2400)
Protection swing frame cabinet (800 x 600 x 2400) D-DT-5420 Sheet 1-6_Rev 0
AC Supply Module D-DT-5423 Sheet 0_Rev 0
Table 2: Hitachi Solution – List of items Required
Item No Item Short Description Item Long Description
P1 common items - engineering
00010-10 hire engnr:candidate;ecsa;2 hire, engineer: seniority: candidate; type:
Electrical/electronic; qualification: bsc eng
/ National diploma; professional
Registration: ecsa; years experience: 2
00010-20 hire hire, engineer: seniority:
Engnr:professional/certified;ecsa professional/certified; type:
Electrical/electronic; qualification: bsc eng
/ National diploma; professional
Registration: ecsa; years experience: 7
00010-30 hire proj hire, project manager: seniority:
Mngr:junior/senior;electrical junior/senior; type: electrical; qualification:
Bsc eng or equivalent; years experience: 3
00010-40 hire drgprsn:junior;technical;4 hire, draughtsperson: seniority: junior; type:
Technical; qualification: national senior
Certificate or n3 engineering; years
Experience: 4; relevant experience: technical
00010-70 integr:line differential relay integration: equipment: line differential
Relay; integration: equipment: line
Differential relay; integration of a free
Issued ge l90, sel411l or siemens 7sl87 third
Party differential relay; this includes wiring
But excludes the supply of ied mounting
Brackets and configuration of relay;
Excludes connection of the ied to the panel
Ethernet switch
00010-80 config sec plnt eqp:5fzd-3x20 configuration, secondary plant equipment:
Configuration type: 5FZD-3X20; customisation
Of the red70, ref620 and rio600 ieds standard
Iec 61850 device configurations including
Goose mapping, compilation of pcm project
(Scd file); vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00010-90 config sec plnt eqp:5fzd-3x40 configuration, secondary plant equipment:
Configuration type: 5FZD-3X40; customisation
Of the red70, ref620 and rio600 ieds standard
Iec 61850 device configurations including
Goose mapping, compilation of pcm project
(Scd file); vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00010- config sec plnt eqp:hardwired 5fzd configuration, secondary plant equipment:
100 -3xx0 configuration type: hardwired 5fzd -3xx0;
Customisation of the red670 and ref620 ieds
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
Standard iec 61850 device configurations
Including goose mapping, compilation of pcm
Project (scd file); vendors are responsible
For ensuring that they are performing
Against the correct drawing revision number
(If applicable).
00010- config sec plnt eqp:5tm-3100 configuration, secondary plant equipment:
110 configuration type: 5TM-3100; customisation
Of the ret670, ref620 and rio600 ieds standard
Iec 61850 device configurations including
Goose mapping, compilation of pcm project
(Scd file); vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00010- config sec plnt eqp:5tm-3200 configuration, secondary plant equipment:
120 configuration type: 5TM-3200; customisation
Of the ret670 ieds standard iec 61850 device
Configuration including goose mapping
Where applicable; vendors are responsible
For ensuring that they are performing
Against the correct drawing revision number
(If applicable).
00010- config sec plnt eqp:5tm-3x00 cust configuration, secondary plant equipment:
130 diff configuration type: 5TM-3X00 cust diff;
Customisation of the red615 ieds standard iec
61850 device configurations including goose
Mapping, compilation of pcm project (scd
File); vendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
00010- config sec plnt eqp:5tc-3200/5tm- configuration, secondary plant equipment:
770 3100 configuration type: 5TC-3200/5TM-3100;
Customisation of the reg-da ieds standard
Iec 61850 device configuration including
Goose mapping, compilation of pcm project
(Scd file); vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00010- config sec plnt eqp:5rf-3100 configuration, secondary plant equipment:
140 configuration type: 5RF-3100; also applicable
To 5BC-3100, customisation of the ref620 ieds
Standard iec 61850 configuration including
Goose mapping, compilation of pcm project
(Scd file); vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00010- config sec plnt eqp:5cf-31x0 configuration, secondary plant equipment:
150 configuration type: 5CF-31X0; also applicable
To 5BS-31X0 and 5VT-31X0, customisation of the
Ref620 and red615 (where applicable); ieds
Standard iec 61850 configuration including
Goose mapping, compilation of pcm project
(Scd file) where applicable; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
00010- config sec plnt eqp:5bp-3700 configuration, secondary plant equipment:
160 configuration type: 5BP-3700; basic
Customisation of iec 61850 communication
Parameters for reb670 ieds; includes ip
Address and technical key name; including
Goose mapping, compilation of pcm project
(Scd file) where applicable; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- config sec plnt eqp:5bp-3500 configuration, secondary plant equipment:
170 configuration type: 5BP-3500; basic
Customisation of iec 61850 communication
Parameters for rec670 ieds. Includes ip
Address and technical key name; including
Goose mapping, compilation of pcm project
(Scd file) where applicable; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- config sec plnt eqp:5bz-3x00 configuration, secondary plant equipment:
180 configuration type: 5BZ-3X00; basic
Customisation of iec 61850 communication
Parameters for rec670 and ref615 ied;
Includes ip address and technical key name;
Including goose mapping, compilation of pcm
Project (scd file) where applicable; vendors
Are responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- config sec plnt eqp:gateway, fzd configuration, secondary plant equipment:
190 tm configuration type: gateway, fzd tm;
Substation gateway configuration per hv
Feeder or transformer bay
00010- config sec plnt eqp:gateway, configuration, secondary plant equipment:
200 other configuration type: gateway, other;
Substation gateway configuration per bus
Coupler, mv feeder, cable feeder, tap change
Or bus zone bays or schemes
00010- config sec plnt eqp:hmi, base configuration, secondary plant equipment;
210 config configuration type hmi
Base config; linking and testing of
Substation human machine interface
Base configuration (basic configuration
Including substation overview, event list,
Alarm list, system monitoring, page
Navigation. Import of rtu config with linking
Of hmi base config)
00010- config sec plnt eqp:hmi, hmi per bay configuration, secondary plant equipment:
220 config configuration type: hmi, sld add 3 bays;
Supplementary line item for configuration
Of up to 3 additional bays on a substation
Human machine interface single line diagram
00010- config sec plnt eqp:hmi, bay fzd tm configuration, secondary plant equipment:
230 configuration type: hmi, bay fzd tm;
Substation hmi configuration of bay page for
A hv feeder or transformer bay
00010- config sec plnt eqp:hmi, bay other configuration, secondary plant equipment:
240 configuration type: hmi, bay other;
Substation hmi configuration of bay page for
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
A mv feeder, cable feeder, tap change or bus
Zone bay/scheme
00010- config sec plnt eqp:mini rtu configuration, secondary plant equipment:
780 configuration type: mini rtu; application
Specific configuration of a mini rtu
00010- config sec plnt eqp:pmrtu configuration, secondary plant equipment:
250 configuration type: pmrtu; application
Specific configuration of a pole-mount rtu
00010- config sec plnt eqp:netw switch configuration, secondary plant equipment:
260 configuration type: netw switch; application
Specific configuration of an industrial
Ethernet switch
00010- config sec plnt eqp:router configuration, secondary plant equipment:
270 configuration type: router; application
Specific configuration of an substation
Router
00010- config sec plnt eqp:serial device configuration, secondary plant equipment:
280 server configuration type: serial device server;
Application specific configuration of a serial
Device server
00010- config sec plnt eqp:gps time synch configuration, secondary plant equipment:
290 configuration type: GPS time synch;
Application specific configuration of a GPS
Time synchronisation device
P1 common items - training
00010- train prsnl:product;1 day train, personnel: course type: product;
300 duration: 1 day
00010- train prsnl:product, train, personnel: course type:
790 PCM/REX670/20/15 (supplier) PCM/REX670/20/15 (supplier); duration: 3 day;
For application in 5FZD-39X0, 5TM-3100, 5BZ-3X00
And 5BP-3X100 schemes; training for 8
Delegates; includes lunch for the trainer
And trainees
00010- train prsnl:hv fdr prot (supplier);5 train, personnel: course type: hv fdr prot
800 day (supplier); duration: 5 day; location: supplier;
Training for 8 delegates; includes lunch for
The trainer and trainees
00010- train prsnl:trfr/tc ctrl prot train, personnel: course type: trfr/tc ctrl
810 (supplier) prot (supplier); duration: 5 day; training for 8
Delegates; includes lunch for the trainer
And trainees
00010- train prsnl:mv fdr prot (supplier);5 train, personnel: course type: mv fdr prot
820 day (supplier); duration: 5 day; training for 8
Delegates; includes lunch for the trainer
And trainees
00010- train prsnl:hi imp b/zne prot train, personnel: course type: hi imp b/zne
830 (supplier) prot (supplier); duration: 2 day; training for 8
Delegates; includes lunch for the trainer
And trainees
00010- train prsnl:rtu500 prtf (supplier);5 train, personnel: course type: rtu500 prtf
840 day (supplier); duration: 5 day; location: supplier
Premises; training for 8 delegates; includes
Lunch for the trainer and trainees
00010- train prsnl:rtu500 ext (supplier);5 train, personnel: course type: rtu500 ext
850 day (supplier); duration: 5 day; including
Archiving, hmi and plc; training for 8
Delegates; includes lunch for the trainer
And trainees
00010- train prsnl:ied interfaces train, personnel: course type: ied interfaces
860 (supplier) (supplier); duration: 5 day; including 61850 on
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
Pcm, goose configuration, iec61850 system
Configuration, report control block
Configuration, template and importing into
Rtutil, adding ied and removing ied, cover
Dnp3 serial to ied; iec61850 excel sheet -
Template and importing into rtutil, adding ied
And removing ied, cover dnp3 serial to ieds;
Training for 8 delegates; includes lunch for
The trainer and trainees
00010- train prsnl:eth netw (supplier);5 train, personnel: course type: eth netw
870 day (supplier); duration: 5 day; training for 8
Delegates; includes lunch for the trainer
And trainees
00010- train prsnl:pcm/rex670/20/15 (ESKOM) train, personnel: course type:
880 PCM/REX670/20/15 (ESKOM); duration: 3 day; for
Application in 5FZD-39X0, 5TM-3100, 5BZ-3X00 and
5BP-3X100 schemes; training for 8 delegates;
Order supplier t and s separately
00010- train prsnl:hv fdr prot (eskom);5 train, personnel: course type: hv fdr prot
890 day (ESKOM); duration: 5 day; schemes; training
For 8 delegates; order supplier t&s
Separately
00010- train prsnl:trfr/tc prot (eskom);5 train, personnel: course type: trfr/tc prot
900 day (ESKOM); duration: 5 day; training for 8
Delegates; order supplier t and s separately
00010- train prsnl:mv fdr prot (eskom);5 train, personnel: course type: mv fdr prot
910 day (ESKOM); duration: 5 day; training for 8
Delegates; order supplier t and s separately
00010- train prsnl:hi imp b/zne prot train, personnel: course type: hi imp b/zne
920 (ESKOM) prot (ESKOM); duration: 2 day; training for 8
Delegates; order supplier t and s separately
00010- train prsnl:product, rtu500 port train, personnel: course type: product,
930 (ESKOM) rtu500 port (ESKOM); duration: 5 day; training
For 8 delegates; order supplier t and s
Separately
00010- train prsnl:product, rtu500 ext train, personnel: course type: product,
940 (ESKOM) rtu500 ext (ESKOM); duration: 5 day; order
Supplier t and s separately
00010- train prsnl:ied interfaces (eskom);5 train, personnel: course type: ied interfaces
950 day (ESKOM); duration: 5 day; including 61850 on
Pcm, goose configuration, iec61850 system
Configuration, report control block
Configuration, template and importing into
Rtutil, adding ied and removing ied, cover
Dnp3 serial to ied; iec61850 excel sheet -
Template and importing into rtutil, adding ied
And removing ied, cover dnp3 serial to ieds;
Order supplier t and s separately
00010- train prsnl:eth netw (eskom);5 day train, personnel: course type: eth netw
960 (ESKOM); duration: 5 day; training for 8
Delegates; order supplier t and s separately
00010- t&s:flights;economy travel and subsistence: type: flights; rate:
310 economy; destinations within south africa
00010- t&s:accomodation;per night travel and subsistence: type: accomodation;
320 rate: per night
00010- t&s:subsistence;per night travel and subsistence: type: subsistence;
330 rate: per night
00010- t&s:travel per kilometer;per km travel and subsistence: type: travel per
340 kilometer; rate: per km
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
00010- t&s:travel;per day travel and subsistence: type: travel; rate:
350 per day; car hire-sedan
00010- train prsnl:low imp/zne prot train, personnel: course type: low imp/zne
970 (supplier) prot (supplier); duration: 2 day; training for 8
Delegates;; includes lunch for the trainer
And trainees
00010- train prsnl:low imp b/zne prot train, personnel: course type: low imp b/zne
980 (ESKOM) prot (ESKOM); duration: 2 day; training for 8
Delegates; order supplier t and s separately
P1 common items - handling
00010- hndl mtrl:panel;store, crate and handle, material: type: panel; method: store,
360 wrap crate and wrap
00010- hndl mtrl:fibre optic patch box handle, material: type: fibre optic patch box;
370 method: store, mount in panel
00010- hndl mtrl:prot & auto eq handle, material: type: prot & auto eq small;
380 small;crating method: crating; applicable to scheme shell,
5Tm cable diff module and ethernet switch.
00010- hndl mtrl:prot & auto eq handle, material: type: prot & auto eq large;
390 large;crating method: crating; applicable to main and
Backup protection module.
P1 common items - transport
00010- trnsp eqp:cable fdr prot, transport, equipment: type: cable fdr prot,
400 transport;road transport; transport method: road; vehicle
Type: crane truck; weight: 3500 kg; delivery
And offloading of mv cable feeder, bus-
Section or vt/cpat schemes to mv switchgear
Supplier, per batch order; to be ordered
With crating for each cable feeder module
Delivered
00010- trnsp eqp:prot/auto panel; 0-50 km transport, equipment: type: prot/auto panel;
610 0-50 km; transport method: road; vehicle type:
Truck; weight: 3500 kg
00010- trnsp eqp:prot/auto panel; 51-100 transport, equipment: type: prot/auto panel;
620 km 51-100 km; transport method: road; vehicle
Type: truck; weight: 3500 kg
00010- trnsp eqp:prot/auto panel; 101-200 transport, equipment: type: prot/auto panel;
630 km 101-200 km; transport method: road; vehicle
Type: truck; weight: 3500 kg
00010- trnsp eqp:prot/auto panel; 201-300 transport, equipment: type: prot/auto panel;
640 km 201-300 km; transport method: road; vehicle
Type: truck; weight: 3500 kg
00010- trnsp eqp:prot/auto panel; 301-400 transport, equipment: type: prot/auto panel;
650 km 301-400 km; transport method: road; vehicle
Type: truck; weight: 3500 kg
00010- trnsp eqp:prot/auto panel; 401-500 transport, equipment: type: prot/auto panel;
660 km 401-500 km; transport method: road; vehicle
Type: truck; weight: 3500 kg
00010- trnsp eqp:prot/auto panel; 501-600 transport, equipment: type: prot/auto panel;
670 km 501-600 km; transport method: road; vehicle
Type: truck; weight: 3500 kg
00010- trnsp eqp:prot/auto panel; 601-700 transport, equipment: type: prot/auto panel;
680 km 601-700 km; transport method: road; vehicle
Type: truck; weight: 3500 kg
00010- trnsp eqp:prot/auto panel 701-800 transport, equipment: type: prot/auto
690 km panel;701-800 km; transport method: road;
Vehicle type: truck; weight: 3500 kg
00010- trnsp eqp:prot/auto panel; 801-900 transport, equipment: type: prot/auto panel;
700 km 801-900 km; transport method: road; vehicle
Type: truck; weight: 3500 kg
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
00010- trnsp eqp:prot/auto panel; 901-1000 transport, equipment: type: prot/auto panel;
710 km 901-1000 km; transport method: road; vehicle
Type: truck; weight: 3500 kg
00010- trnsp eqp:prot/auto panel; 1001- transport, equipment: type: prot/auto panel;
720 1100 km 1001-1100 km; transport method: road; vehicle
Type: truck; weight: 3500 kg
00010- trnsp eqp:prot/auto panel; 1101- transport, equipment: type: prot/auto panel;
730 1200 km 1101-1200 km; transport method: road; vehicle
Type: truck; weight: 3500 kg
00010- trnsp eqp:prot/auto panel; 1201- transport, equipment: type: prot/auto panel;
740 1300 km 1201-1300 km; transport method: road; vehicle
Type: truck; weight: 3500 kg
00010- trnsp eqp:prot/auto panel; 1301- transport, equipment: type: prot/auto panel;
750 1400 km 1301-1400 km; transport method: road; vehicle
Type: truck; weight: 3500 kg
00010- trnsp eqp:prot/auto panel; 1401- transport, equipment: type: prot/auto panel;
760 1500 km 1401-1500 km; transport method: road; vehicle
Type: truck; weight: 3500 kg
00010- unld eqp:prot/auto panel;crane;320 unload, equipment: type: prot/auto panel;
410 kg method: crane; weight: 320 kg
00010- unld eqp:crate kg;crane;350 unload, equipment: type: crate kg; method:
420 crane; weight: 350
00010- t&s:travel for erection;0-50 km travel and subsistence: type: travel for
430 erection; rate: 0-50 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;51-100 km travel and subsistence: type: travel for
440 erection; rate: 51-100 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;101-200 km travel and subsistence: type: travel for
450 erection; rate: 101-200 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;201-300 km travel and subsistence: type: travel for
460 erection; rate: 201-300 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;301-400 km travel and subsistence: type: travel for
470 erection; rate: 301-400 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;401-500 km travel and subsistence: type: travel for
480 erection; rate: 401-500 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;501-600 km travel and subsistence: type: travel for
490 erection; rate: 501-600 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;601-700 km travel and subsistence: type: travel for
500 erection; rate: 601-700 km; ; vendors are
Responsible for ensuring that they are
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;701-800 km travel and subsistence: type: travel for
510 erection; rate: 701-800 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;801-900 km travel and subsistence: type: travel for
520 erection; rate: 801-900 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;901-1000 km travel and subsistence: type: travel for
530 erection; rate: 901-1000 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;1001-1100 travel and subsistence: type: travel for
540 km erection; rate: 1001-1100 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;1101-1200 travel and subsistence: type: travel for
550 km erection; rate: 1101-1200 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;1201-1300 travel and subsistence: type: travel for
560 km erection; rate: 1201-1300 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;1301-1400 travel and subsistence: type: travel for
570 km erection; rate: 1301-1400 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- t&s:travel for erection;1401-1500 travel and subsistence: type: travel for
580 km erection; rate: 1401-1500 km; ; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00010- erect pnl:prot/auto panel erect, panel: type: prot/auto panel
00010- create doc:erection safety file create, document: type: erection safety file;
600 media: hard copy
P1 common items - spares
00020 cord comm:computer;lg 3 cord, communication: type: computer; length:
M;copper;rj45 3 m; conductor: copper; connectors: rj45
00030 relay ctrl:10 a;8 co;110 v;8pdt;base relay, control: contact rating: 10 a; contact
Arrangement: 8 co; coil voltage: 110 v; action:
8Pdt; mount: base; terminal: 32 pin plug-in;
Contact material: agni; enclosure rating: ip
40; specification: ansi c37.90; Type: latching,
Std speed; bj8t; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00040 relay ctrl:10 a;8 co;220 v;8pdt;base relay, control: contact rating: 10 a; contact
Arrangement: 8 co; coil voltage: 220 v; action:
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
8Pdt; mount: base; terminal: 32 pin plug-in;
Contact material: agni; enclosure rating: ip
40; specification: ansi c37.90; Type: latching,
Std speed; bj8t
00050 relay ctrl:10 a;4 co;110 relay, control: contact rating: 10 a; contact
Vdc;4pdt;agni arrangement: 4 co; coil voltage: 110 vdc;
Action: 4pdt; mount: plug-in; terminal: 16 pin;
Contact material: agni; enclosure rating: ip
40; specification: ansi c37.90; Type: latching;
Arteche bf4t; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00060 relay ctrl:10 a;4 co;220 relay, control: contact rating: 10 a; contact
Vdc;4pdt;agni arrangement: 4 co; coil voltage: 220 vdc;
Action: 4pdt; mount: plug-in; terminal: 16 pin;
Contact material: agni; enclosure rating: ip
40; specification: ansi c37.90; Type: latching;
Arteche bf4t; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00070 base rly:jn-de ip10, latching;wd 84 base, relay: type: jn-de ip10, latching; width: 84
Mm mm; height: 105 mm; material: plastic; for bj8
Relay; din rail mounting
00080 base rly:fn-de ip10, latching;wd 44 base, relay: type: fn-de ip10, latching; width:
Mm 44 mm; height: 105 mm; material: plastic; for bf4
Relay
00090 relay ctrl:10 a;3 co;110 relay, control: contact rating: 10 a; contact
Vdc;3pdt;base arrangement: 3 co; coil voltage: 110 vdc;
Action: 3pdt; mount: base; terminal: 16 pin
Plug-in; contact material: agni; enclosure
Rating: ip 40; specification: ansi c37.90; Type:
Latching; bf3r ; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00100 relay ctrl:10 a;3 co;220 relay, control: contact rating: 10 a; contact
Vdc;3pdt;base arrangement: 3 co; coil voltage: 220 vdc;
Action: 3pdt; mount: base; terminal: 16 pin
Plug-in; contact material: agni; enclosure
Rating: ip 40; specification: ansi c37.90; Type:
Latching; bf3r ; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00110 base rly:latching;wd 44 mm;ht 105 base, relay: type: latching; width: 44 mm;
Mm height: 105 mm; material: plastic; arteche bf
Relay base fn-de ip10; din rail mounting
00120 relay ctrl:rf-4r-220vdc-op01000;10 a relay, control: contact rating: 10 a; contact
Arrangement: 4 co; coil voltage: 220 vdc;
Action: 4pdt; mount: base; terminal: 16 pin
Plug-in; contact material: agni; enclosure
Rating: ip 40; specification: ansi c37.90; Type:
Latching; oem p/n: RF-4R-220VDC-OP01000;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
00130 relay ctrl:1svr405622r3100;10 a;3 co relay, control: contact rating: 10 a; contact
Arrangement: 3 co; coil voltage: 230 vac;
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
Action: spdt; mount: pluggable; terminal: pin;
Contact material: agni; enclosure rating:
Ip40; specification: en 60255-1-00; type: non-
Latching; oem p/n: 1svr405622r3100; CR-U230AC3L
00140 base rly:1svr405660r1100;latching base, relay: type: latching; width: 44 mm;
Height: 105 mm; material: plastic; length: 75
Mm; oem p/n: 1svr405660r1100; CR-U3SM
00150 relay ctrl:1svr405622 r8100;10 a;3no relay, control: contact rating: 10 a; contact
3Nc arrangement: 3no 3nc; coil voltage: 110 vdc;
Action: spdt; mount: pluggable; terminal: pin;
Oem p/n: 1svr405622 r8100; CR-U110DC3L;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
00160 relay ctrl:1svr405622 r9100;10 a;3no relay, control: contact rating: 10 a; contact
3Nc arrangement: 3no 3nc; coil voltage: 200 vdc;
Action: spdt; mount: pluggable; terminal: pin;
Oem p/n: 1svr405622 r9100; CR-U220DC3L;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
00170 comp, prot scm:rcpm1 pr5651 2029-AA component, protection scheme: component
Type: rcpm1 contact protection module;
Voltage: 110/220V vdc; oem p/n: rcpm1 pr5651
2029-AA; bb rcpm device, two units per module;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
00180 comp, prot scm:btcs110;110/220 vdc component, protection scheme: component
Type: trip circuit supervision module;
Voltage: 110/220 vdc; oem p/n: btcs110; vendors
Are responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00190 switch pushbtn:flush;red;110/220 switch, pushbutton: head style: flush; color:
Vdc red; electrical rating: 110/220 vdc; action:
Spst; contact arrangement: 1 NO; mount: clip-
On; oem p/n: 1sfa611610r1001; MCB-10;
Emergency, complete with: MP1-10R operator
Pn 1sfa611100r1001, MCBH-00 contact holder pn
1Sfa611605r1100 and ysf cover
00200 module comm:mod600alecmfo;rio600 module, communication: type: rio600; oem p/n:
Mod600alecmfo; with multimode fiber optic lc
Port; vendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
00210 module pwr module, power supply: type: rio600; input:
Sup:mod600apsmh07;rio600 100/240 vac; 110/250 vdc; output: 7 w; oem p/n:
Mod600apsmh07; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00220 mod, elec:mod600adom4r;rio600, do module, electronic: type: rio600, do; voltage:
250 v ac/dc; oem p/n: mod600adom4r; vendors
Are responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00230 mod, elec:mod600ascm8h;rio600 , hs module, electronic: type: rio600 , hs do;
Do voltage: 100/240 vac; 110/250 vdc; oem p/n:
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
Mod600ascm8h; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00240 mod, elec:mod600adim8h;rio600, di module, electronic: type: rio600, di; voltage:
110/250 vdc; oem p/n: mod600adim8h; vendors
Are responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00250 switch selctr:cr-0577a;manual;3;16 switch, selector: operated: manual; position:
A 3; potential: 110/220 vdc; current: 16 a; contact
Arrangement: 4p3t; type: tns; oem p/n: CR-0577A
00260 comp, prot scm:cm-ess.2MS;110/220 Component, protection scheme: component
Vdc type: dc voltage monitoring device; voltage:
110/220 vdc; standard: iec/en 60947-5-1, iec/en
60255-27, en 50178; oem p/n: CM-ESS.2MS; vendors
Are responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00270 switch selctr:cr-0317a;manual;2;16 switch, selector: operated: manual; position:
A 2; potential: 110/220 vdc; current: 16 a; contact
Arrangement: 4pdt; type: rotary, bfi; oem p/n:
CR-0317A; breaker fail isolate; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00280 switch selctr:cr-1821a;manual;2;16 switch, selector: operated: manual; position:
A 2; potential: 110/220 vdc; current: 16 a; contact
Arrangement: 3pdt; type: rotary, bfi; oem p/n:
CR-1821A; breaker fail isolate; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00290 blck, test:ct 2 x 4-way;600 vac;30 a block, test: type: ct 2 x 4-WAY; voltage rating:
600 vac; current rating: 30 a; oem p/n:
Ftlp08aaaxxxsl; secucontrol ftl test block,
8-WAY; excluding test fingers and test block
Dust cover; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00300 blck, test:ct 2 x 4-way;600 vac;30 a block, test: type: ct 2 x 4-WAY; voltage rating:
600 vac; current rating: 30 a; oem p/n:
Ftlp08aaaxxxsl; secucontrol ftl test block,
8-WAY; excluding test fingers and test block
Dust cover; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00310 blck, test:ct 1 x 4-WAY, vt 4-way;30 a block, test: type: ct 1 x 4-WAY, vt 4-WAY;
Voltage rating: 600 vac; current rating: 30 a;
Oem p/n: ftlp08aadxxxsl; secucontrol ftl
Test block, 8-WAY; excluding test fingers and
Test block dust cover; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00320 blck, test:ftlp04acxxxxsl;600 vac;30 block, test: type: ct 1 x 2-WAY, vt 1 x 2-WAY;
A voltage rating: 600 vac; current rating: 30 a;
Oem p/n: ftlp04acxxxxsl; excluding test
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
Fingers and clear transparent cover;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
00330 blck, test:ftlp04afxxxxsl;600 vac;30 block, test: type: ct 1 x 2-WAY, ct 1 x 2-WAY;
A voltage rating: 600 vac; current rating: 30 a;
Oem p/n: ftlp04afxxxxsl; excluding test
Fingers and clear transparent cover;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
00340 blck, test:ct 1 x 4-way;600 vac;30 a block, test: type: ct 1 x 4-WAY; voltage rating:
600 vac; current rating: 30 a; oem p/n:
Ftlp04aaxxxxsl; secucontrol ftl test block,
4-WAYVENDORS are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
00340-1 blck, test:ct 3 x 2-WAY, vt 2-way;30 a block, test: type: ct 3 x 2-WAY, vt 1 x 2-WAY;
Voltage rating: 600 vac; current rating: 30 a;
Oem p/n: ftlp08abcxxxsl; secucontrol ftl
Test block, 8-WAY; excluding test fingers and
Test block dust cover; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00350 cover:dust;wd 46 mm;plastic;clear cover: type: dust; dimensions: wd 46 mm;
Material: plastic; color: clear; application: 4-
Way secucontrol ftl test block; oem p/n:
Ftdc04
00360 cover:dust;wd 92 mm;plastic;clear cover: type: dust; dimensions: wd 92 mm;
Material: plastic; color: clear; application: 8-
Way secucontrol ftl test block; oem p/n:
Ftdc08, dust
00370 ied:fdr, ref620;48-250 vdc device, intelligent electronic: type: fdr,
Ref620; voltage: 48-250 vdc; application:
Directional overcurrent and earth fault
Protection; oem p/n: nbfnabaaabh1bnl11g;
1A/5A ct, single ct bank; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00380 bkr cct lv:2cds272061r0205;din breaker, circuit, low voltage: mount: din rail;
Rail;mcb type: mcb; control voltage: 110/220 vdc; poles:
2; current rating: 20 a; voltage protection
Level: 110/220 vdc; rated insulation voltage:
253 vac phase to ground; 440 vac phase to
Phase; impulse withstand voltage: 4 kv; short
Time current: 10 ka; pollution class: 2;
Specification: iec/en 60898-2; application:
Voltage transformer; protection: general
Load; oem p/n: 2cds272061r0205; S202M-B20UC;
Including wiring
00390 bkr cct lv:2cds272061r0165;din breaker, circuit, low voltage: mount: din rail;
Rail;mcb type: mcb; control voltage: 110/220 vdc; poles:
2; current rating: 16 a; voltage protection
Level: 110/220 vdc; rated insulation voltage:
253 vac phase to ground; 440 vac phase to
Phase; impulse withstand voltage: 4 kv; short
Time current: 10 ka; pollution class: 2;
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
Specification: iec/en 60898-2; application:
Voltage transformer; protection: general
Load; oem p/n: 2cds272061r0165; S202M-B16UC;
Including wiring
00400 bkr cct lv:2cds272061r0105;din breaker, circuit, low voltage: mount: din rail;
Rail;mcb type: mcb; control voltage: 110/220 vdc; poles:
2; current rating: 10 a; voltage protection
Level: 110/220 vdc; rated insulation voltage:
253 vac phase to ground; 440 vac phase to
Phase; impulse withstand voltage: 4 kv; short
Time current: 10 ka; pollution class: 2;
Specification: iec/en 60898-2; application:
Voltage transformer; protection: general
Load; oem p/n: 2cds272061r0105; S202M-B10UC;
Including wiring
00410 bkr cct lv:2cds272061r0065;din breaker, circuit, low voltage: mount: din rail;
Rail;mcb type: mcb; control voltage: 110/220 vdc; poles:
2; current rating: 6 a; voltage protection
Level: 110/220 vdc; rated insulation voltage:
253 vac phase to ground; 440 vac phase to
Phase; impulse withstand voltage: 4 kv; short
Time current: 10 ka; pollution class: 2;
Specification: iec/en 60898-2; application:
Voltage transformer; protection: general
Load; oem p/n: 2cds272061r0065; S202M-B6UC;
Including wiring
00420 bkr cct lv:2cds2733341r0034;din breaker, circuit, low voltage: mount: din rail;
Rail;mcb type: mcb; control voltage: 230 vac; poles: 3;
Current rating: 2 a; voltage protection
Level: 230 vac; rated insulation voltage: 253
Vac phase to ground; 440 vac phase to phase;
Impulse withstand voltage: 4 kv; short time
Current: 10 ka; pollution class: 3;
Specification: iec/en 60898-1; application:
Voltage transformer; protection: general
Load; oem p/n: 2cds2733341r0034; S203-C2;
Including wiring
00430 bkr cct lv:cds273061r0165;din breaker, circuit, low voltage: mount: din rail;
Rail;mcb type: mcb; control voltage: 110/220 vdc; poles:
3; current rating: 16 a; voltage protection
Level: 110/220 vdc; rated insulation voltage:
253 vac phase to ground; 440 vac phase to
Phase; impulse withstand voltage: 4 kv; short
Time current: 10 ka; pollution class: 2;
Specification: iec/en 60898-2; application:
Voltage transformer; protection: general
Load; oem p/n: cds273061r0165; S203M-B16UC;
Including wiring
00440 earth earth leakage: type: mcb; current: 16 a;
Leakage:2csr252001r1164;mcb;16 a potential: 230 vac; pole: 2; leakage current: 16
A; interrupt capacity: 10 ka; specification:
Iec/en 60947-2 and 61009-1; oem p/n:
2Csr252001r1164; ds202 ac-c16/0,03
00450 contact aux:2cds200912r0001;no contact, auxiliary: type: mcb auxilliary;
Nc;10 a contact arrangement: NO NC; current: 10 a;
Potential: 110/220 vdc; material: plastic; oem
P/n: 2cds200912r0001; S2C-H6R
00460 contact aux:2cds200936r0001;no contact, auxiliary: type: mcb auxilliary;
Nc;10 a contact arrangement: NO NC; current: 10 a;
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
Potential: 110/220 vdc; material: plastic; oem
P/n: 2cds200936r0001; S2C-H11L
00470 base rly:5619 483-a;latching;wd 12c base, relay: type: latching; width: 12c; height:
2U; material: plastic; oem p/n: 5619 483-A
00480 relay ctrl:rf-4r-110vdc-op01000;10 a relay, control: contact rating: 10 a; contact
Arrangement: 4 co; coil voltage: 110 vdc;
Action: 4pdt; mount: base; terminal: 16 pin
Plug-in; contact material: agni; enclosure
Rating: ip 40; specification: ansi c37.90; Type:
Changeover; oem p/n: RF-4R-110VDC-OP01000;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
00490 base rly:latching;wd 44 mm;ht 105 base, relay: type: latching; width: 44 mm;
Mm height: 105 mm; material: plastic; rf4r
00500 comp, prot scm:rcpm1 pr5651 2029-AA component, protection scheme: component
Type: rcpm1 contact protection module;
Voltage: 110/220 vdc; oem p/n: rcpm1 pr5651
2029-AA; rcpm device, one unit per module;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
00510 base rly:5619 622-a;latching;wd base, relay: type: latching; width: 6c; height:
6C;ht 2u 2u; material: plastic; oem p/n: 5619 622-A
00520 switch selctr:cr-1822a;manual;2;16 switch, selector: operated: manual; position:
A 2; potential: 110/220 vdc; current: 16 a; contact
Arrangement: 8pdt; type: rotary, bzi; oem p/n:
CR-1822A; bus-zone isolate; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00530 switch selctr:cr-1823a;manual;2;16 switch, selector: operated: manual; position:
A 2; potential: 110/220 vdc; current: 16 a; contact
Arrangement: 5pdt; type: rotary, bfi; oem p/n:
CR-1823A; breaker fail isolate
00540 switch selctr:cr-1824a;manual;2;16 switch, selector: operated: manual; position:
A 2; potential: 110/220 vdc; current: 16 a; contact
Arrangement: 18pdt; type: rotary, bzi; oem p/n:
CR-1824A; bus-zone isolate; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00550 switch selctr:cr-2901;manual;3;16 a switch, selector: operated: manual; position:
3; potential: 110/220 vdc; current: 16 a; contact
Arrangement: 2p3t; type: rotary, tns; oem p/n:
CR-2901; tns; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00560 switch selctr:cr-2026;manual;3;16 a switch, selector: operated: manual; position:
3; potential: 110/220 vdc; current: 16 a; contact
Arrangement: 10p3t; type: rotary; oem p/n: cr-
2026; tns; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00570 switch selctr:cr-2026;manual;3;16 a switch, selector: operated: manual; position:
3; potential: 110/220 vdc; current: 16 a; contact
Arrangement: 10p3t; type: rotary, bfi; oem p/n:
CR-2026; tns; vendors are responsible for
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00580 switch selctr:cr-3025;manual;3;16 a switch, selector: operated: manual; position:
3; potential: 110/220 vdc; current: 16 a; contact
Arrangement: 6p3t; type: rotary switch, bfi;
Oem p/n: CR-3025; tns; vendors are responsible
For ensuring that they are performing
Against the correct drawing revision number
(If applicable).
00590 relay ctrl:10 a;8 co;110 v;8pdt;base relay, control: contact rating: 10 a; contact
Arrangement: 8 co; coil voltage: 110 v; action:
8Pdt; mount: base; terminal: 32 pin plug-in;
Contact material: agni; enclosure rating: ip
40; specification: ansi c37.90; Type: latching,
Std speed; bj8r; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00600 relay ctrl:10 a;8 co;220 v;8pdt;base relay, control: contact rating: 10 a; contact
Arrangement: 8 co; coil voltage: 220 v; action:
8Pdt; mount: base; terminal: 32 pin plug-in;
Contact material: agni; enclosure rating: ip
40; specification: ansi c37.90; Type: latching,
Std speed; bj8r; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
P1
00610 switch netw: RSP30-08033O6TT- switch, network: type: substation gateway;
Sk9v9hse2s afs665ss3g4t4t port type: (8) 10/100 mb copper rj45, (3) gb sfp;
Oem p/n: afs665ss3g4t4t; (3) gb sfp ports
Populated with (3) m-sfp-sx-lc 1 gb modules;
Including (3) 3m copper ethernet patch leads;
Excludes fibre optic patch leads; vendors
Are responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00620 switch netw:rsp30-08033o6zt- switch, network: type: hv feeder bay; port
Sk9v9hse2s type: (4) 100mb sfp, (3) gb sfp; oem p/n:
Afs665ss3g4t4s; l1 mounting plate, (1) 100mb
Sfp port populated with m-fast-sfp-lc and (2)
Gb sfp ports populated with (2) msfpsx-lc 1 gb
Modules; including (5) 3m ethernet copper
Patch leads; 2 x rj45 ethernet port (for
Mounting in the 2u ethernet plate); excludes
Fibre optic patch leads
00630 switch netw:rsp30-08033o6zt- switch, network: type: trfr bay; port type: (4)
Sk9v9hse2s 100mb sfp, (3) gb sfp; oem p/n: afs665ss3g4t4s;
S1 mounting plate (4) 100mb sfp port
Populated with (3) m-fast-sfp-lc and (1) m-fast-
Sfp-tx) and (2) gb sfp ports populated with (2)
Msfpsx-lc 1gb modules; with (6) 3 m ethernet
Copper patch leads and 2 x rj45 ethernet
Port (for mounting in the 2u ethernet plate);
Excludes fibre optic patch leads
00640 switch netw:rsp30-08033o6tt- switch, network: type: rural fdr/buszone;
Sk9v9hse2s port type: (8) 10/100MB copper rj45, (3) x gb sfp;
Oem p/n: afs665ss3g4t4t; for mv fdr bay
Offboard or trfr (NO piu) s1 plate; (2) sfp
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
Ports populated with (2) m-sfp-sx-lc 1 gb
Modules; including (7) 3 m and (1) 5 m ethernet
Copper patch leads; all additional patch
Leads need to be ordered separately; 2 x rj45
Ethernet port (for mounting in the 2u
Ethernet plate); excluding fibre optic patch
Leads
00650 switch netw:rsp30-08033o6tt- switch, network: type: onboard fdr; port
Sk9v9hse2s type: (8) 10/100MB copper rj45, (3) x gb sfp; oem
P/n: afs665ss3g4t4t; mcb with din rail; (3) sfp
Ports populated with (2) m-sfp-sx-lc 1 gb
Modules; including (1) 1 m, (1) 3 m and (6) 5 m
Ethernet copper patch leads; 1 x rj45
Ethernet port (for mounting in the ethernet
Socket); all additional patch leads need to be
Ordered separately; excluding fibre optic
Patch leads
P1
00660 socket elect:3u panel mount;3 socket, electrical: type: 3u panel mount;
Ka;230 vac contact: 3 ka; potential: 230 vac;
Configuration: on/off switch, earth leakage,
2 sockets; connection: 3-PIN RSA; current: 16 a;
Includes overload PROTECTION-16A earth
Leakage mcb; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00670 ied:extended rio600 breaker piu device, intelligent electronic: type: extended
Rio600 breaker piu; voltage: 100/240 vac; 110/250
Vdc; application: process interface unit; oem
P/n: aa-aa-lbgcaacaab-ab-acaab-ab-a; optional
Ied with wiring tail; for transformer 5JB-3200;
Excluding motorised isolators and fixed
Earths; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00680 comp, prot scm:ethernet port component, protection scheme: component
Plate type: ethernet port plate; ncluding 2x rj45
Ports, 2x 2m cat5e copper cables with rj45
Connectors and lable; for 5FZD-3XX0, 5RF-3100,
5BC-3100, 5CF/BS-3150, 5BP-3X00 and 5FZ-3X00;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
P2
00690 comp, prot scm:5fzd-3xx0 scm;110 component, protection scheme: component
Vdc type: 5FZD-3XX0 SCM; voltage: 110 vdc;
Standard: 240-76625593 rev1; scheme shell
Suitable for 5FZD-3XX0; including vt selection
Relay wiring and bases, vt supply
Mcbs/distribution to the protection modules;
Excluding vt selection relays and ct
Shorting relays and bases; the scheme shell
To be ordered with an (optional) ethernet
Switch; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
00700 comp, prot scm:5fzd-3xx0 scm;220 component, protection scheme: component
Vdc type: 5FZD-3XX0 SCM; voltage: 220 vdc;
Standard: 240-76625593 rev1; scheme shell
Suitable for 5FZD-3XX0; includes vt selection
Relay wiring and bases, vt supply
Mcbs/distribution to the protection modules;
Excluding vt selection relays and ct
Shorting relays and bases; the scheme shell
To be ordered with an (optional) ethernet
Switch; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00710 SCM, prot:5fzd-3x20 hv fdr main;110 scheme, protection: type: 5FZD-3X20 hv fdr
Vdc main; voltage: 110 vdc; drawing NO: D-DT-15009;
Line dist/diff, 3-POLE tripping, 1/5A ct, apply
With scheme shell, hv feeder backup or main2
And 5JB-3100 or without 5JB-3100 for
Hardwired option; including jumpers to
Scheme shell; excluding: swingframe panel,
External hardwired disturbance recorder
Interface, irig-b timing input card, 1u
Ethernet port option and (1) hardwired
Legacy snubber circuit; hardwired to yard
00720 SCM, prot:5fzd-3x20 hv fdr main;220 scheme, protection: type: 5FZD-3X20 hv fdr
Vdc main; voltage: 220 vdc; drawing NO: D-DT-15009;
Line dist/diff, 3-POLE tripping, 1/5A ct, apply
With scheme shell, hv feeder backup or main2
And 5JB-3100 or without 5JB-3100 for
Hardwired option; including jumpers to
Scheme shell; excluding: swingframe panel,
External hardwired disturbance recorder
Interface, irig-b timing input card, ethernet
Port option and (1) hardwired legacy snubber
Circuit
00730 SCM, prot:5fzd-3x40 hv fdr main;110 scheme, protection: type: 5FZD-3X40 hv fdr
Vdc main; voltage: 110 vdc; drawing NO: D-DT-15010;
Line dist/diff, 1-POLE tripping, 1/5A ct, apply
With scheme shell, hv feeder backup or main2
And 5JB-3100 or without 5JB-3100 for
Hardwired option; including jumpers to
Scheme shell; excluding: swingframe panel,
External hardwired disturbance recorder
Interface, irig-b timing input card, ethernet
Port option and (1) hardwired legacy snubber
Circuit
00740 SCM, prot:5fzd-3x40 hv fdr main;220 scheme, protection: type: 5FZD-3X40 hv fdr
Vdc main; voltage: 220 vdc; drawing NO: D-DT-15010;
Line dist/diff, 1-POLE tripping, 1/5A ct, apply
With scheme shell, hv feeder backup or main2
And 5JB-3100 or without 5JB-3100 for
Hardwired option; including jumpers to
Scheme shell; excluding: swingframe panel,
External hardwired disturbance recorder
Interface, irig-b timing input card, ethernet
Port option and (1) hardwired legacy snubber
Circuit
00750 SCM, prot:5fzd-3220 hv fdr main2;110 scheme, protection: type: 5FZD-3220 hv fdr
Vdc main2; voltage: 110 vdc; drawing NO: D-DT-15011;
Line dist/diff, 3-POLE tripping, 1/5A ct, apply
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
With scheme shell, hv feeder main module and
5Jb3100 or without 5JB-3100 for hardwired
Option; main 2 module includes the required
Snubber units; excluding: swingframe panel,
External hardwired disturbance recorder
Interface, irig-b timing input card, ethernet
Port option and (1) hardwired legacy snubber
Circuit
00760 SCM, prot:5fzd-3220 hv fdr main2;220 scheme, protection: type: 5FZD-3220 hv fdr
Vdc main2; voltage: 220 vdc; drawing NO: D-DT-15011;
Line dist/diff, 3-POLE tripping, 1/5A ct, apply
With scheme shell, hv feeder main module and
5Jb3100 or without 5JB-3100 for hardwired
Option; main 2 module includes the required
Snubber units; excluding: swingframe panel,
External hardwired disturbance recorder
Interface, irig-b timing input card, ethernet
Port option and (1) hardwired legacy snubber
Circuit
00770 SCM, prot:5fzd-3240 hv fdr main2;110 scheme, protection: type: 5FZD-3240 hv fdr
Vdc main2; voltage: 110 vdc; drawing NO: D-DT-15015;
Line dist/diff, 1-POLE tripping, 1/5A ct, apply
With scheme shell, hv feeder main module and
5Jb3100 or without 5JB-3100 for hardwired
Option; main 2 module includes the required
Snubber units; excluding: swingframe panel,
External hardwired disturbance recorder
Interface, irig-b timing input card, ethernet
Port option and (1) hardwired legacy snubber
Circuit
00780 SCM, prot:5fzd-3240 hv fdr main2;220 scheme, protection: type: 5FZD-3240 hv fdr
Vdc main2; voltage: 220 vdc; drawing NO: D-DT-15015;
Line dist/diff, 1-POLE tripping, 1/5A ct, apply
With scheme shell, hv feeder main module and
5Jb3100 or without 5JB-3100 for hardwired
Option; main 2 module includes the required
Snubber units; excluding: swingframe panel,
External hardwired disturbance recorder
Interface, irig-b timing input card, ethernet
Port option and (1) hardwired legacy snubber
Circuit
00790 SCM, prot:5fzd-3920 hv fdr backup scheme, protection: type: 5FZD-3920 hv fdr
3P;110 backup 3p; voltage: 110; drawing NO: D-DT-15009;
Line dist/diff, 3-POLE tripping, 1/5A ct, apply
With scheme shell, hv feeder main module and
5Jb3100 or without 5JB-3100 for hardwired
Option
00800 SCM, prot:5fzd-3920 hv fdr backup scheme, protection: type: 5FZD-3920 hv fdr
3P;220 backup 3p; voltage: 220; drawing NO: D-DT-15009;
Line dist/diff, 3-POLE tripping, 1/5A ct, apply
With scheme shell, hv feeder main module and
5Jb3100 or without 5JB-3100 for hardwired
Option
00810 SCM, prot:5fzd-3940 hv fdr backup scheme, protection: type: 5FZD-3940 hv fdr
1P;110 backup 1p; voltage: 110; drawing NO: D-DT-15010;
Line dist/diff, 1-POLE tripping, 1/5A ct, apply
With scheme shell, hv feeder main module and
5Jb3100 or without 5JB-3100 for hardwired
Option
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
00820 SCM, prot:5fzd-3940 hv fdr backup scheme, protection: type: 5FZD-3940 hv fdr
1P;220 backup 1p; voltage: 220; drawing NO: D-DT-15010;
Line dist/diff, 1-POLE tripping, 1/5A ct, apply
With scheme shell, hv feeder main module and
5Jb3100 or without 5JB-3100 for hardwired
Option
00820-1 module comm:1mrk002311-ba, 1550nm component, protection scheme: component
Type: 5FZD-3XX0, 1550nm single mode link
Specification; standard: 240-84854878 rev1; main
Protection module with 1550nm single mode
Interface with optical budget 27db in place
Of 1310 nm single mode transceiver in slot
X305 or x306 ; to be ordered at same time as
Main module; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00820-2 module comm:1mrk002307-aa, x21 component, protection scheme: component
Type: 5FZD-3XX0, x21 card; standard: 240-
84854878 rev1; main protection module with x21
Card interface in place of 1310 nm single
Mode transceiver in slot x305 or 306; to be
Ordered at same time as main module;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
00830 comp, prot scm:5fzd-3xx0, 820nm component, protection scheme: component
Type: 5FZD-3XX0, 1 x c37.94, 820Nm; standard: 240-
84854878 rev1; main protection module with
820Nm short range 3 km multimode interface
In place of 1310 nm single mode transceiver in
Slot x305; to be ordered at same time as main
Module; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
03860 module comm:3t diff 1310nm module, communication: type: 5FZD-3XX0, 3-T
Diff,1310nm sm; main protection module to
Provide three terminal line diff via 1310nm
Single mode transceivers in slot x306; to be
Ordered at same time as main module or as a
Spare; vendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
03860-1 module comm:rea spa/fibre port module, communication: type: 5fzd- 3xx0, rea
Spa/fibre port
00840 comp, prot scm:5fzd-3xx0, 3t diff component, protection scheme: component
1550Nm type: 5FZD-3XX0, 3t diff 1550nm; standard: 240-
84854878 rev1; main protection module to
Provide three terminal line diff via 1550nm
Single mode transceivers in the slot x306;
Max range is 125 km; to be ordered at same
Time as main module or as a spare; vendors
Are responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00850 comp, prot scm:5fzd-3xx0, byp ct component, protection scheme: component
Type: 5FZD-3XX0, byp ct; standard: 240-84854878
Rev1; shorting option for 5FZD-3XX0 scheme
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
Shell; to be ordered with the scheme shell
When the feeder bypass is required; vendors
Are responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00860 conv, elect:dc-dc;24-250 vdc;48 vdc converter, electrical: type: dc-dc; input
Voltage: 24-250 vdc; output voltage: 48 vdc;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
00870 comp, prot scm:5fzd-3xx0,ext dist component, protection scheme: component
Rec type: 5fzd-3xx0,ext dist rec; standard: 240-
84854878 rev1; hardwired disturbance
Recorder interface for 5FZD-3XX0 main
Module; including fitting of a X91/92 slot
Output card, terminals with backplate, mcbs
And wiring; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
00880 comp, prot scm:110/220 vdc component, protection scheme: component
Type: 5FZD-3XX0, ext ambient measurement
Input; voltage: 110/220 vdc; temperature
Range: 0-300 deg c; including sensor, 40
Meters of screened cable and terminals;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
00890 mod, elec:irig-b input;110/220 vdc module, electronic: type: irig-b input;
Voltage: 110/220 vdc; external time
Synchronisation input (IRIG-B002 interface
Card, position x312); including 40 m screened
Cable with connectors and placement of
Card 1mrk002305; vendors are responsible
For ensuring that they are performing
Against the correct drawing revision number
(If applicable).
00900 comp, prot scm:5fzd-3xx0, vsr component, protection scheme: component
Type: 5FZD-3XX0, vsr; standard: 240-84854878
Rev1; vt selection option for 5FZD-3XX0
Scheme shell; relays only as bases and
Wiring included as standard in scheme shell;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
00910 interface:aa-aa-lbgcaacaacaab-ab- interface: type: extended rio600 breaker piu;
Ab-a oem p/n: aa-aa-lbgcaacaacaab-ab-ab-a;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
00920 cord comm:x21 port pulg cord, communication: type: hv feeder, x21
Adaptor;lg 10 m port plug adaptor; length: 10 m; conductor:
Copper; connectors: D-15 micro x D-15;
Adaptor, for x21 comm card
00930 mod, elec:aa-lbgcaacaab-ab-ab-a module, electronic: type: hv feeder rio600
Breaker piu; voltage: 100- 240 VAC/110 -250 vdc;
Oem p/n: aa-lbgcaacaab-ab-ab-a; drawing NO: d-
DT-15900, level 19; device only; vendors are
Responsible for ensuring that they are
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
Performing against the correct drawing
Revision number (if applicable).
00940 comp, prot scm:pr5651 2033.BA Component, protection scheme: component
Type: hv feeder, snubber device for 3 pole
Scheme; voltage: 110/220 vdc; oem p/n: pr5651
2033.BA; Drawing NO: D-DT-15009; includes
Fitment into main module; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00950 comp, prot scm:pr5651 2033.BA Component, protection scheme: component
Type: hv feeder, snubber device for 1 pole
Scheme; voltage: 110/220 vdc; oem p/n: pr5651
2033.BA; Drawing NO: D-DT-15010; includes (2)
Snubber devices, fitment into main module;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
Hv feeder mixed technology
P2
00960 module comm:5fzd-3xx0, 1 x c37.94 Module, communication: type: 5FZD-3XX0, 1 x
C37.94; Main protection module with 820 nm
(Short range 3km) multimode interface; to be
Ordered as a spare; vendors are responsible
For ensuring that they are performing
Against the correct drawing revision number
(If applicable).
00970 mod, elec:1mrk000508-b;110 vdc module, electronic: type: binary input module
Card; voltage: 110 vdc; oem p/n: 1MRK000508-B;
Input module only; specify alternative input
Voltage: 48 vdc (a) or 220 vdc (c); vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
00980 mod, elec:1mrk000173-b;110 vdc module, electronic: type: binary input/output
Module card; voltage: 110 vdc; oem p/n:
1MRK000173-B; input module only; specify
Alternative input voltage: 220 vdc (c);
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
00990 mod, elec:1mrk000614-ab;110 vdc module, electronic: type: binary output
Module card; voltage: 110 vdc; oem p/n:
1MRK000614-AB; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
01000 mod, elec:1mrk002239-bb;90-250 vdc module, electronic: type: current and
Voltage input; voltage: 90-250 vdc; oem p/n:
1MRK002239-BB; includes 6 voltages and 6
Currents; specify 5a rated current input if
Required; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
01010 module comm:1mrk005500-ba module, communication: type: ethernet sfp
Module; oem p/n: 1MRK005500-BA; plug-in for
Slots x301 or x302 with rj45 connector;
Vendors are responsible for ensuring that
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
They are performing against the correct
Drawing revision number (if applicable).
01020 module comm:1mrk005500-aa module, communication: type: ethernet sfp
Module; oem p/n: 1MRK005500-AA; plug-in for
Slots x301 or x302 with lc connector;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
01030 gps:1mrk002305-aa;hv feeder global positioning system: type: hv feeder
Module module; oem p/n: 1MRK002305-AA; IRIG-B002
Interface, slot position x312; for red670 main
Ied
01040 module comm:1mrk002309-aa module, communication: type: hv feeder rs458
Card; oem p/n: 1MRK002309-AA; for slot position
X313; vendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
01050 module comm:1mrk002122-ab;c37.94 Module, communication: type: hv feeder,
820Nm c37.94 820Nm; oem p/n: 1MRK002122-AB; for slots
X305 or x306; including multimode st
Connectors
01060 module comm:1mrk002311-aa;1310nm module, communication: type: hv feeder,
1310Nm single mode link specification; oem p/n:
1MRK002311-AA; with optical budget 23db for
Slotds x305 or x306; including single mode fc
Connectors
01070 module comm:1mrk002311-ba;1550nm module, communication: type: hv feeder,
1550Nm single mode link specification; oem p/n:
1MRK002311-BA; with optical budget 27db for
Slotds x305 or x306; including single mode fc
Connectors
03870 module comm:1mrk002307-aa;x21 module, communication: type: hv feeder, x21
Card; oem p/n: 1MRK002307-AA; internal
Teleprotection and comm card for slots x305
Or x306; including galvanic 15 pin connector;
Excluding x21 comm card port plug adaptor
03880 module comm:x21 port plug module, communication: type: hv feeder, x21
Adaptor port plug adaptor; D-15 micro to D-15
01080 mod, elec:pr5651 2033-ba;110/220 v module, electronic: type: tripping diode
Module; voltage: 110/220 v; oem p/n: pr5651 2033-
Ba; 2 diodes per module; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
01090 switch selctr:cr-3031a;manual;3;16 switch, selector: operated: manual; position:
A 3; potential: 110/220 v; current: 16 a; contact
Arrangement: 14p3t; type: tns; oem p/n: cr-
3031A; vendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
01100 switch selctr:cr-3030a;manual;3;16 switch, selector: operated: manual; position:
A 3; potential: 110/220 v; current: 16 a; contact
Arrangement: 8p3t; type: rotary, tns; oem p/n:
CR-3030A; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
01110 ied:1a red670 ied;90-250 vdc device, intelligent electronic: type: 1a red670
Ied; voltage: 90-250 vdc; excludes x5, x9 bom,
Irig-b and 2nd ldcm cards 110 v; ordering
Code: red670*2.2-F00X00-A00000000010000100-
B51100001101000000011110000-
C11001111100100010210000000-D22101011-T0000-
E22200-F2-S0-G211-H10200100000-K01011111-L1100-
M0210111-P00000000000000000-B1X0-BX-CB-B-A6-
CD1N1XAD1D1XX-PXXXBXXXXXGX; DX698 Contract -
2.2 Ied;vendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
01120 ied:5a red670 ied;90-250 vdc device, intelligent electronic: type: 5a red670
Ied; voltage: 90-250 vdc; excludes x5, x9 bom,
Irig-b and 2nd ldcm cards 110 v; ordering
Code: red670*2.2-F00X00-A00000000010000100-
B51100001101000000011110000-
C11001111100100010210000000-D22101011-T0000-
E22200-F2-S0-G211-H10200100000-K01011111-L1100-
M0210111-P00000000000000000-B1X0-BX-CB-B-A7-
CD1N1XAD1D1XX-PXXXBXXXXXGX; dx698 contract
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
01130 ied:1a red670 ied;90-250 vdc device, intelligent electronic: type: 1a red670
Ied; voltage: 90-250 vdc; excludes x5, x9 bom,
Irig-b and the 2nd ldcm cards 220 v; ordering
Code: red670*2.2-F00X00-A00000000010000100-
B51100001101000000011110000-
C11001111100100010210000000-D22101011-T0000-
E22200-F2-S0-G211-H10200100000-K01011111-L1100-
M0210111-P00000000000000000-B1X0-BX-CB-B-A6-
CE1P1XAE1E1XX-PXXXBXXXXXGX; dx698 contract
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
01140 ied:5a red670 ied;90-250 vdc device, intelligent electronic: type: 5a red670
Ied; voltage: 90-250 vdc; excludes x5, x9 bom,
Irig-b and the 2nd ldcm cards 220 v; ordering
Code: red670*2.2-F00X00-A00000000010000100-
B51100001101000000011110000-
C11001111100100010210000000-D22101011-T0000-
E22200-F2-S0-G211-H10200100000-K01011111-L1100-
M0210111-P00000000000000000-B1X0-BX-CB-B-A7-
CE1P1XAE1E1XX-PXXXBXXXXXGX; dx698 contract
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
P3
01150 comp, prot scm:5tm-3100 SCM shell component, protection scheme: component
Type: 5TM-3100 SCM shell; including: vt supply
Mcbs/distribution to the protection modules
And ethernet front ports module, vt
Selection relays, wiring and bases (ordering
Option); should be ordered with ethernet
Switch module for piu option; vendors are
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
01160 comp, prot scm:5tm-3200 SCM shell component, protection scheme: component
Type: 5TM-3200 SCM shell; including: vt supply
Mcbs/distribution to the protection modules
And ethernet front ports module, vt
Selection relays, wiring and bases (ordering
Option); should be ordered with ethernet
Switch module for panel ied communication;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
01170 SCM, prot:5tm-3100 main;110 vdc scheme, protection: type: 5TM-3100 main;
Voltage: 110 vdc; drawing NO: D-DT-15207;
Transformer main, 1/5A ct; apply with scheme
Shell and 5JB-3200; including jumpers to
Scheme shell; excluding swingframe panel;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
01180 SCM, prot:5tm-3100 main;220 vdc scheme, protection: type: 5TM-3100 main;
Voltage: 220 vdc; drawing NO: D-DT-15207;
Transformer main, 1/5A ct; apply with scheme
Shell and 5JB-3200; including jumpers to
Scheme shell; excluding swingframe panel;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
01190 SCM, prot:5tm-3200;110 vdc scheme, protection: type: 5TM-3200; voltage:
110 vdc; drawing NO: D-DT-15210; transformer,
1/5A ct, legacy hardwired interface; apply
With scheme shell; excluding swingframe
Panel; vendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
01200 SCM, prot:5tm-3200;220 vdc scheme, protection: type: 5TM-3200; voltage:
220 vdc; drawing NO: D-DT-15210; transformer,
1/5A ct, legacy hardwired interface; apply
With scheme shell; excluding swingframe
Panel; vendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
01210 SCM, prot:5tm-3100 backup;110 vdc scheme, protection: type: 5TM-3100 backup;
Voltage: 110 vdc; drawing NO: D-DT-15207;
Transformer, 1a ct; apply with scheme shell
And 5JB-3200; including jumpers to scheme
Shell and main module; excluding swingframe
Panel; vendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
01220 SCM, prot:5tm-3100 backup;220 vdc scheme, protection: type: 5TM-3100 backup;
Voltage: 220 vdc; drawing NO: D-DT-15207;
Transformer, 1a ct; apply with scheme shell
And 5JB-3200; including jumpers to scheme
Shell and main module; excluding swingframe
Panel; vendors are responsible for ensuring
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
That they are performing against the
Correct drawing revision number (if
Applicable).
01230 comp, prot scm:5tm-3100, 2 hiz REF component, protection scheme: component
Type: 5TM-3100, 2 hiz REF; voltage: 110/220 vdc;
High impedance hv and mv REF option for 5tm-
3100 backup module; including metrosils and
Wiring; to be ordered together with a backup
Module; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
01240 comp, prot scm:110/220 vdc component, protection scheme: component
Type: hv high impedance fault detector;
Voltage: 110/220 vdc; high impedance hv and mv
REF option for 5TM-3100 backup module;
Including metrosils and wiring; to be
Ordered together with a backup module;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
01250 comp, prot scm:5tm-3200, 1 hiz REF component, protection scheme: component
Type: 5TM-3200, 1 hiz REF; high impedance hv and
Mv REF option for 5TM-3200 backup module;
Including metrosils and wiring and
Stabilising resistors; to be ordered
Together with a backup module; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
01260 comp, prot scm:5tm-3x00, cust mtr component, protection scheme: component
Type: 5TM-3X00, cust mtr; standard: 240-84854878
Rev1; vendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
01270 comp, prot scm:110/220 vdc component, protection scheme: component
Type: 5TM-3X00, cable diff module; voltage:
110/220 vdc; drawing NO: D-DT-15207;
Transformer cable diff module, 1/5A ct, apply
With scheme shell; including jumpers to
Scheme shell; excluding swingframe panel;
Vendors are responsible for ensuring that
They are performing against the correct
Drawing revision number (if applicable).
01280 comp, prot scm:5tm-3100, hv vsr component, protection scheme: component
Type: 5TM-3100, hv vsr; hv busbar voltage with
(2) bf3r; voltage determined by scheme
Ratingvendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
01290 comp, prot scm:5tm-3x00, mv vsr component, protection scheme: component
Type: 5TM-3X00, mv vsr; hv busbar voltage with
(2) bf3r; voltage determined by scheme
Rating; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
01300 ied:breaker piu, rio600 piu;110/220 device, intelligent electronic: type: breaker
Vdc piu, rio600 piu; voltage: 110/220 vdc; oem p/n: aa-
Aa-lbgcaacaacaab-ab-ab-a; including wiring
Tails; to be ordered with 5TM-3100 main
Protection; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
01310 ied:trfr piu, rio600 piu;110/220 vdc device, intelligent electronic: type: trfr piu,
Rio600 piu; voltage: 110/220 vdc; oem p/n: aa-aa-
Lbgcaacaacaagaab-adda; including wiring
Tails; to be ordered with 5TM-3100 main
Protection; vendors are responsible for
Ensuring that they are performing against
The correct drawing revision number (if
Applicable).
01320 ied:1a ret670 ied;110 vdc device, intelligent electronic: type: 1a ret670
Ied; voltage: 110 vdc; ct input; ordering code:
Ret670*2.2-F00X00-A00010030300000000-
B00000000000000000000000000-
C33002421202300000010000000-D22211010-T0000-
E22100-F3-S0-G320-H00000010001-K00000000-L1100-
M0301222-P00000000000000000-B1X0-CX-CB-B-A3A3-
CD1AD1XX-PXXXXXXXXXXXGX; dx698 contract -
2.2 Ied; vendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
01330 ied:5a ret670 ied;110 vdc device, intelligent electronic: type: 5a ret670
Ied; voltage: 110 vdc; ct input; ordering code:
Ret670*2.2-F00X00-A00010030300000000-
B00000000000000000000000000-
C33002421202300000010000000-D22211010-T0000-
E22100-F3-S0-G320-H00000010001-K00000000-L1100-
M0301222-P00000000000000000-B1X0-CX-CB-B-A4A4-
CD1AD1XX-PXXXXXXXXXXXGX; dx698 contract -
2.2 Ied; vendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
01340 ied:1a ret670 ied;220 vdc device, intelligent electronic: type: 1a ret670
Ied; voltage: 220 vdc; ct input; ordering code:
Ret670*2.2-F00X00-A00010030300000000-
B00000000000000000000000000-
C33002421202300000010000000-D22211010-T0000-
E22100-F3-S0-G320-H00000010001-K00000000-L1100-
M0301222-P00000000000000000-B1X0-CX-CB-B-A3A3-
CE1AE1XX-PXXXXXXXXXXXGX; dx698 contract - 2.2
Ied; vendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
01350 ied:5a ret670 ied;220 vdc device, intelligent electronic: type: 5a ret670
Ied; voltage: 220 vdc; ct input; ordering code:
Ret670*2.2-F00X00-A00010030300000000-
B00000000000000000000000000-
C33002421202300000010000000-D22211010-T0000-
E22100-F3-S0-G320-H00000010001-K00000000-L1100-
M0301222-P00000000000000000-B1X0-CX-CB-B-A4A4-
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
559-1826396412 Rev 1
Identifier
Effective Date 21 October 2025
Review Date October 2028
CE1AE1XX-PXXXXXXXXXXXGX; dx698 contract - 2.2
Ied; vendors are responsible for ensuring
That they are performing against the
Correct drawing revision number (if
Applicable).
01350-1 ied:1a ret670 ied;110 vdc;5tm3200 device, intelligent electronic: type: 1a ret670
Ied; voltage: 110 vdc; ct input; ordering
Code:ret670*2.2-F00X00-A00010010200000000-
B00000000000000000000000000-
C330024010023000000100000000- D22210010-T0000-
E002100-F0-S0-G320- H00000010001-K00000000-L0100-
M03011000-P000000000000000000-B1X0- cx-cb-b-
A3A3-CD1AD1D1D1-PXXXXXXXXXXXGX; dx698
Contract - 2.2 Ied; for 5tm3200; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
01350-2 ied:5a ret670 ied;110 vdc;5tm3200 device, intelligent electronic: type: 5a ret670
Ied; voltage: 110 vdc; ct input; ordering
Code:ret670*2.2-F00X00-A00010010200000000-
B00000000000000000000000000-
C330024010023000000100000000- D22210010-T0000-
E002100-F0-S0-G320- H00000010001-K00000000-L0100-
M03011000-P000000000000000000-B1X0- cx-cb-b-
A4A4-CD1AD1D1D1-PXXXXXXXXXXXGXX; dx698
Contract - 2.2 Ied; for 5tm3200; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
01350-3 ied:1a ret670 ied;220 vdc;5tm3200 device, intelligent electronic: type: 1a ret670
Ied; voltage: 220 vdc; ct input; ordering
Code:ret670*2.2-F00X00-A00010010200000000-
B00000000000000000000000000-
C330024010023000000100000000- D22210010-T0000-
E002100-F0-S0-G320- H00000010001-K00000000-L0100-
M03011000-P000000000000000000-B1X0- cx-cb-b-
A3A3-CE1AE1E1E1-PXXXXXXXXXXXGX; dx698
Contract - 2.2 Ied; for 5tm3200; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
01350-4 ied:5a ret670 ied;220 vdc;5tm3200 device, intelligent electronic: type: 5a ret670
Ied; voltage: 220 vdc; ct input; ordering
Code:ret670*2.2-F00X00-A00010010200000000-
B00000000000000000000000000-
C330024010023000000100000000- D22210010-T0000-
E002100-F0-S0-G320- H00000010001-K00000000-L0100-
M03011000-P000000000000000000-B1X0- cx-cb-b-
A4A4-CE1AE1E1E1-PXXXXXXXXXXXGX; dx698
Contract - 2.2 Ied; for 5tm3200; vendors are
Responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
01360 ied:5tm-3100, hiz ref;110/220 vdc device, intelligent electronic: type: 5TM-3100,
Hiz REF; voltage: 110/220 vdc; oem p/n: 2V73-AAA;
High impedance hiz REF (rms relay); vendors
Are responsible for ensuring that they are
Performing against the correct drawing
Revision number (if applicable).
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by third
parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 147
File name: Scope of Work _ Protection and Automation Schemes_Finalised
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Methodology
Source: Annexure A - Detailed Scope of Work.pdf (unknown)The work involves configuration of secondary plant equipment, including customisation of IEDs (such as RED670, REF620, RIO600) with standard IEC 61850 device configurations, GOOSE mapping, and compilation of PCM project (SCD) files. It also includes configuration of substation gateways, HMI base configurations, and application-specific configuration of network switches, routers, serial device servers, and GPS time synchronisation devices.
Experience & Qualifications
Source: Annexure A - Detailed Scope of Work.pdf (unknown)The project requires hiring an engineer with a BSc Eng or National Diploma, professional registration with ECSA, and 2 years of experience. A project manager with a BSc Eng or equivalent and 3 years of experience is also required. A draughtsperson with a National Senior Certificate or N3 Engineering and 4 years of relevant technical experience is needed.
Quality Management
Source: Annexure A - Detailed Scope of Work.pdfBase config; linking and testing of
Pricing Schedule
Source: Annexure A - Detailed Scope of Work.pdf (unknown)The project includes travel and subsistence costs for economy flights within South Africa, accommodation per night, subsistence per night, travel per kilometre, and car hire (sedan).
Compliance Requirements
Source: Annexure A - Detailed Scope of Work.pdf (unknown)No specific requirements found
B-BBEE Minimum Level: 110
Evaluation Criteria
Source: Annexure B - Detailed Technical Evaluation Criteria.pdf (unknown)Unable to extract eligibility criteria
Technical Specifications
Source: Annexure B - Detailed Technical Evaluation Criteria.pdf (unknown)The purpose of this document is to define the technical evaluation criteria to be applied in assessing supplier
responses to the Expression of Interest (EOI) for the manufacture, configuration, testing, supply, delivery,
erection and training of a previously developed range of approved Protection, Control and Substation
Automation Schemes (predominantly based on the GE and Hitachi protection relays) including the swing frame
cabinets to house these schemes, to Eskom Distribution. This evaluation is intended to determine supplier
capability as per a) – d) below such that a formalised contract process can be undertaken based on these
results.
a) Manufacture, configure, supply, deliver and erection of schemes including swing frame panels based on
Eskom’s existing approved designs
b) Modify and adapt designs for future requirements
c) Provide training on Eskom’s existing approved designs
d) Provide technical product support, training, etc.
2.1 Scope
2.1.1 Purpose
The purpose of this document is to define the technical evaluation criteria to be applied in assessing supplier
responses to the Expression of Interest (EOI).
2.1.2 Applicability
This document shall apply to Eskom’s Distribution Division.
2.2 Normative/informative references
Parties using this document shall apply the most recent edition of the documents listed in the following
paragraphs.
2.2.1 Normative
Not applicable.
2.2.2 Informative
Not applicable.
2.3 Definitions
2.3.1 General
Definition Description
Eskom evaluating The persons appointed by Eskom to perform the technical evaluation of tender
representative(s) submissions in line with Eskom’s requirements.
Normative Documents that shall be read in conjunction with this report and are binding on
Tenderers.
ESKOM copyright protected
When downloaded from the WEB, this document is uncontrolled and the responsibility rests with the user
to ensure it is in line with the authorized version on the WEB.
Document Classification: Controlled Disclosure
TECHNICAL EVALUATION CRITERIA FOR PHASE 5 Unique Identifier: 240-171000652
Protection and substation automation
Revision: 2EQUIPMENT – BASED ON HITACHI AND IST SOLUTION
Page:
2.3.2 Disclosure classification
Controlled disclosure: controlled disclosure to external parties (either enforced by law, or discretionary).
2.4 Abbreviations
Abbreviation Description
IED Intelligent Electronic Device
2.5 Roles and responsibilities
It is proposed that:
compliance to the stipulated requirements.
2.6 Process for monitoring
Eskom will monitor the compliance to this document as part of the evaluation of submitted EOI.
2.7 Related/supporting documents
Not applicable.
The evaluation exercise is performed by the Eskom evaluation team. The following criteria will be used to
assess the tenderer’s capability to meet Eskom’s requirements as specified in the EOI. The evaluation is
qualitative (EOI-based) and not intended for final tender award scoring.
3.1 Evaluation Approach
Suppliers will be assessed based on documented evidence submitted in response to the EOI.
3.2 Scoring Philosophy
Although this is an EOI, a structured scoring model is used to enable comparison:
Rating Description
4 Fully compliant
2 Partially compliant
0 Non-compliant/No Response
ESKOM copyright protected
When downloaded from the WEB, this document is uncontrolled and the responsibility rests with the user
to ensure it is in line with the authorized version on the WEB.
Document Classification: Controlled Disclosure
TECHNICAL EVALUATION CRITERIA FOR PHASE 5 Unique Identifier: 240-171000652
Protection and substation automation
Revision: 2EQUIPMENT – BASED ON HITACHI AND IST SOLUTION
Page:
4.1 Summary of Evaluation Categories
No Category Weight
(%)
1 Capability to supply and support existing Eskom scheme designs by OEM/Value Added 60
Reseller
2 Experience with Protection and Automation scheme manufacturing, configuration, and 30
training
3 Ability to supply items for a proposed production contract and costing provided 10
4.2 Detailed Evaluation Criteria
4.2.1 Capability to supply and support existing Eskom scheme designs
EOI Query Requirement Evidence Required
schemes supplied in this contract can be supported and OEMs/VARs
guarantees/warranties will be upheld by the OEM.
schemes required for this contract can be supplied timeously. OEMs/VARs
4.2.2 Experience with Protection and Automation scheme manufacturing, configuration
and training
EOI Query Requirement Evidence Required
with manufacturing of Protection Schemes, Gateway
schemes or similar type equipment as required by this
contract.
be manufactured and supplied within 15 weeks factory layout diagram
of protection and SCADA gateway devices provided as supporting
evidence
details
4.2.3 Ability to supply items for a proposed production contract – as per currently
accepted designs and costing provided
EOI Query Requirement Evidence Required
Hitachi/GE Protection relay configurations
Hitachi/GE Gateway configurations
Hitachi/GE HMI configurations
Networking device configurations
GPS device configurations
P2. HV Feeder Scheme (5FZD3xxx or 5FZD5xxx) and all
associated options and spares
ESKOM copyright protected
When downloaded from the WEB, this document is uncontrolled and the responsibility rests with the user
to ensure it is in line with the authorized version on the WEB.
Document Classification: Controlled Disclosure
TECHNICAL EVALUATION CRITERIA FOR PHASE 5 Unique Identifier: 240-171000652
Protection and substation automation
Revision: 2EQUIPMENT – BASED ON HITACHI AND IST SOLUTION
Page:
P3. Transformer Scheme (5TM3x00, 5TM5x00) and all
associated options and spares
P4. Tap Change Scheme (5TC3x00, 5TC5x00) and all
associated options and spares
P5. Multipurpose Feeder Scheme (5RF/BC/EG3x00,
5RF/BC/EG5x00) and all associated options and spares
P6. Cable Feeder Scheme (5CF/BS/VT31x0, 5CF/BS/VT51x0)
and all associated options and spares
P7. Low Impedance Buszone Protection (5BP3x00, 5BP5x00)
and all associated options and spares
P8. High Impedance Busbar Protection (5BZ3x00, 5BZ5x00)
and all associated options and spares
P12. Substation Gateway (5AGW3x00, 5AGW5x00)
P13. Pole Mount Gateway (5AGW3300, 5AGW5x00)
P1 and P15. Networking Devices (Switches, Routers, Serial
Port Servers) all associated options and spares
P16. GPS Time Synchronisation Devices all associated options
and spares
Junction Boxes (5JB3x00 and 5JB5x00) all associated options
and spares
Swing Frame Panels all associated options and spares
Transport and Erection of Panels
Costing Table populated Table 2 from EOI
Authorization
Not applicable.
Date Rev. Compiler Remarks
Aug 2026 2 Marlini Sukhnandan Updated references to RFI with EOI. Referred to
the correct EOI query numbers.
July 2026 1 Marlini Sukhnandan First issue.
Andrew Craib
Mpai Letebele
Not applicable.
ESKOM copyright protected
When downloaded from the WEB, this document is uncontrolled and the responsibility rests with the user
to ensure it is in line with the authorized version on the WEB.
Methodology
Source: Annexure B - Detailed Technical Evaluation Criteria.pdf. Introduction .................................................................................................................................................. 3
2.1 Scope ................................................................................................................................................. 3
2.1.1 Purpose .................................................................................................................................. 3
2.1.2 Applicability ............................................................................................................................ 3
2.2 Normative/informative references ...................................................................................................... 3
2.2.1 Normative ............................................................................................................................... 3
2.2.2 Informative ............................................................................................................................. 3
2.3 Definitions ........................................................................................................................................... 3
2.3.1 General .................................................................................................................................. 3
2.3.2 Disclosure classification ......................................................................................................... 4
2.4 Abbreviations ...................................................................................................................................... 4
2.5 Roles and responsibilities .................................................................................................................. 4
2.6 Process for monitoring ....................................................................................................................... 4
2.7 Related/supporting documents .......................................................................................................... 4
3.1 Evaluation Approach .......................................................................................................................... 4
3.2 Scoring Philosophy ............................................................................................................................. 4
4.1 Summary of Evaluation Categories .................................................................................................... 5
4.2 Detailed Evaluation Criteria ................................................................................................................ 5
4.2.1 Capability to supply and support existing Eskom scheme designs ....................................... 5
4.2.2 Experience with Protection and Automation scheme manufacturing, configuration and
training ................................................................................................................................... 5
4.2.3 Ability to supply items for a proposed production contract – as per currently accepted
designs ................................................................................................................................... 5
Authorization ................................................................................................................................................ 6
Revisions ..................................................................................................................................................... 6
Development team ...................................................................................................................................... 6
Acknowledgements ..................................................................................................................................... 6
assess the tenderer’s capability to meet Eskom’s requirements as specified in the EOI. The evaluation is
qualitative (EOI-based) and not intended for final tender award scoring.
3.1 Evaluation Approach
Experience & Qualifications
Source: Annexure B - Detailed Technical Evaluation Criteria.pdf2 Experience with Protection and Automation scheme manufacturing, configuration, and 30
training
3 Ability to supply items for a proposed production contract and costing provided 10
4.2 Detailed Evaluation Criteria
4.2.1 Capability to supply and support existing Eskom scheme designs
schemes required for this contract can be supplied timeously. OEMs/VARs
4.2.2 Experience with Protection and Automation scheme manufacturing, configuration
and training
with manufacturing of Protection Schemes, Gateway
schemes or similar type equipment as required by this
contract.
Compliance Requirements
Source: Annexure B - Detailed Technical Evaluation Criteria.pdf (unknown)No specific requirements found
Section
Source: Annexure B - Detailed Technical Evaluation Criteria.pdfTitle: TECHNICAL EVALUATION Unique Identifier: 240-171000652
TECHNICAL EVALUATION CRITERIA FOR PHASE 5 Unique Identifier: 240-171000652
Briefing Session
Source: E3269DXGOUR - EOI - Protection Schemes - Reissue.pdf (EOI)A non-compulsory clarification meeting with representatives of Eskom will take place as follows: Date: 10 September 2026.
Contact Information
Source: E3269DXGOUR - EOI - Protection Schemes - Reissue.pdf (EOI){"name":"MS Teams","email":"[email protected]","phone":"0499461018","department":null,"address":"f training and product"}
Evaluation Criteria
Source: E3269DXGOUR - EOI - Protection Schemes - Reissue.pdf (EOI)Bidders must be suitably qualified and capable of engineering, manufacturing, supplying, testing, delivering, supporting and, where required, installing the existing approved protection, control and substation automation schemes in accordance with Eskom's specifications, approved drawings, system architecture and technical requirements. They must confirm their ability to supply and support specific makes, models, part numbers or configurations essential for compatibility; any proposed equivalent must be clearly identified and supported by sufficient technical evidence for Eskom's assessment and approval. Bidders must provide letters of confirmation from the OEM and/or VAR that all Hitachi/GE schemes described in Annexure A can be supported, with all Eskom-required guarantees/warranties upheld, and can be manufactured, configured, integrated and delivered within 15 weeks from the date of order. Bidders must provide evidence of previous experience in the past 2 years in manufacturing protection schemes, gateway schemes or similar equipment, and evidence of experience in configuring and integrating IEC 61850 devices and supporting protection schemes and substation SCADA gateway devices. Bidders must also provide details of their current manufacturing facility with a factory layout diagram, and list the number of current technical resources available. The EOI submission must be signed by a person duly authorised to act on behalf of the company. Eskom reserves the right to reject any or all EOI offers and to select or disqualify any participant at its discretion.
Technical Specifications
Source: E3269DXGOUR - EOI - Protection Schemes - Reissue.pdf (EOI)Eskom Holdings SOC Ltd (“Eskom”) intends to initiate the commercial process to establish a contract
for the engineering, supply, training and support of a previously developed range of approved
Protection, Control and Substation Automation Schemes (predominantly based on the GE and Hitachi
protection relays) including the swing frame cabinets to house these schemes, to Eskom Distribution
over a period of up to four (4) years as per the following drawings. Note that the exact part and type
numbers are listed in the respective drawings. A table listing these drawings is provided in Section
5.4 below.
It is Eskom’s expectation that the previous design intent will be sustained, in terms of the overall
system architecture, functionality offered, brand and types of IEDs utilised (including part and type
numbers), guarantees and the provision of product support. The design details of the previously
developed and approved schemes and swing frame cabinets are captured in the engineering drawings
and base configurations which can be requested from Eskom and will be supplied (pdf’s) subject to
signature of a Non-Disclosure Agreement. These drawings will assist in understanding the scope and
in the completion of this EOI.
Eskom previously established and concluded contracts for the development of Phase V Protection,
Control and Substation Automation equipment. The solutions developed were an integrated system,
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by
third parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 16
File name: EOI - Protection Schemes - Reissue
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
240-72663051 Rev 4
Identifier
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
with one Supplier’s solution based predominantly on the Hitachi range of protection and automation
IEDs while the other Supplier’s solution was based predominantly on the GE range of protection and
automation IEDs. It was originally intended to extend these existing contracts for four years with the
respective suppliers, however due to challenges with the current contract and associated contracts,
this could not be concluded. It is Eskom’s intention to now re-establish these supply contracts with the
already developed solutions.
Pursuant to Eskom’s intended commercial process, the supplier will be required to:
functionality in devices offered but not yet used,
Eskom Distribution, as and when required, over a period of up to four (4) years,
5.1 EOI Returnables
The interested parties shall return information for the queries detailed below. Interested parties shall
populate columns coloured in yellow.
Query No Query Description Supplier Response Supplier
Comments (if
required)
you can supply and support.
provide a letter of confirmation from required
OEM and/or VAR that all the Hitachi/GE
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by
third parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 16
File name: EOI - Protection Schemes - Reissue
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
240-72663051 Rev 4
Identifier
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
schemes described in Annexure A –
Scope of Work attached to this EOI
document supplied in a contract can be
supported and all Eskom required
guarantees/warranties will be upheld by
the OEM.
provide a letter of confirmation from required
OEM and/or VAR that all the Hitachi/GE
schemes described in Annexure A –
Scope of Work attached to this EOI
document can be manufactured,
configured, integrated and delivered
within an expected timeline of 15 weeks
from the date of the Eskom order.
experience in the past 2 years with by Supplier
manufacturing of Protection Schemes,
Gateway schemes and/or similar type
equipment to Eskom’s requirements
described in the Scope of Work
document.
A table that lists five projects, names of
customers/companies with a customer
contact person and their contact details
(email/phone number), project quantities
and types and description of equipment
manufactured shall be provided.
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by
third parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 16
File name: EOI - Protection Schemes - Reissue
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
240-72663051 Rev 4
Identifier
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
automation schemes, swing frame manufacturing
cabinets and PIU junction boxes as capability & factory
described in the Scope of Work layout drawing
document can be manufactured and
configured within the required period of
15 weeks.
Also provide details (including physical
address) of your current manufacturing
facility with a factory layout diagram.
have in configuring and integrating information to be
61850 devices across multiple schemes provided
in a bus as well as experience in
supporting protection schemes and
substation SCADA gateway devices in
the last 2 years. A table listing the
projects, customer, work description
showing evidence of the above shall be
provided.
resources (and qualifications, years of required information
experience) that will be available to to be provided.
support a possible 4-year contract in the
near future.
training you have provided on by the Supplier
Protection, Networking and Gateway
devices similar to what is requested in
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by
third parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 16
File name: EOI - Protection Schemes - Reissue
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
240-72663051 Rev 4
Identifier
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
the Scope of Work document, over the
past 2 years. A table listing the course
title, course description and number of
attendees for some of the courses
provided over the past 2 years covering
protection, automation and networking
shall be provided.
is listed in the Table 1 of this EOI below. below.
Please indicate in the column provided
in this table if the associated line item
can be manufactured, configured,
supplied, supported and delivered
timeously (within 15 weeks from date of
order).
schemes/equipment listed in Table 2 in below.
the EOI below.
Previous design drawings, may be requested from Eskom and will be supplied subject to signature of
a Non-Disclosure Agreement, are available should they be required to assist in completion of this EOI.
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by
third parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 16
File name: EOI - Protection Schemes - Reissue
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
240-72663051 Rev 4
Identifier
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
5.2 List of items Required – Table 1
Required item indicate if the comments (supplier should
Following can be indicate if there are any
Provided (y/n) compliance deviations from
Table 2 and table 3 from
Annexure a- scope of work
Document)
Hitachi/GE IED Training (as
per Scope of Work - Table 2
and 3)
Hitachi/GE Protection relay
configurations (as per Scope of
Work - Table 2 and 3)
Hitachi/GE Gateway
configurations (as per Scope of
Work - Table 2 and 3)
Hitachi/GE HMI configurations
(as per Scope of Work - Table
2 and 3)
Networking device
configurations (as per Scope of
Work - Table 2 and 3)
GPS device configurations (as
per Scope of Work - Table 2
and 3)
P2. HV Feeder Scheme
(5FZD3xxx or 5FZD5xxx) and
all associated options and
spares (as per Scope of Work -
Table 2 and 3)
P3. Transformer Scheme
(5TM3x00, 5TM5x00) and all
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by
third parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 16
File name: EOI - Protection Schemes - Reissue
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
240-72663051 Rev 4
Identifier
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
associated options and spares
(as per Scope of Work - Table
2 and 3)
P4. Tap Change Scheme
(5TC3x00, 5TC5x00) and all
associated options and spares
(as per Scope of Work - Table
2 and 3)
P5. Multipurpose Feeder
Scheme (5RF/BC/EG3x00,
5RF/BC/EG5x00) and all
associated options and spares
(as per Scope of Work - Table
2 and 3)
P6. Cable Feeder Scheme
(5CF/BS/VT31x0,
5CF/BS/VT51x0) and all
associated options and spares
(as per Scope of Work - Table
2 and 3)
P7. Low Impedance Buszone
Protection (5BP3x00,
5BP5x00) and all associated
variants, options and spares
(as per Scope of Work - Table
2 and 3)
P8. High Impedance Busbar
Protection (5BZ3x00,
5BZ5x00) and all associated
variants, options and spares
(as per Scope of Work - Table
2 and 3)
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by
third parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 16
File name: EOI - Protection Schemes - Reissue
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
240-72663051 Rev 4
Identifier
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
P12. Substation Gateway
(5AGW3x00, 5AGW5x00) and
all associated variants, options
and spares (as per Scope of
Work - Table 2 and 3)
P13. Pole Mount Gateway
(5AGW3300, 5AGW5x00) and
all associated variants, options
and spares (as per Scope of
Work - Table 2 and 3)
P1 and P15. Networking
Devices (Switches, Routers,
Serial Port Servers) and all
associated variants, options
and spares (as per Scope of
Work - Table 2 and 3)
P16. GPS Time
Synchronisation Devices and
all associated variants, options
and spares (as per Scope of
Work - Table 2 and 3)
Junction Boxes (5JB3x00 and
5JB5x00) and all associated
variants, options and spares
(as per Scope of Work - Table
2 and 3)
Swing Frame Panels all
associated options and spares
(as per Scope of Work - Table
2 and 3)
Delivery and Erection of
Schemes (as per Scope of
Work - Table 2 and 3)
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by
third parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 16
File name: EOI - Protection Schemes - Reissue
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
240-72663051 Rev 4
Identifier
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
5.3 List of Items to provide indicative pricing – Table 2
Please provide costs assuming a 4-year production contract will be established with the estimated
quantities indicated below. Please cost based on the included components as stipulated in Annexure
A – Scope of Work.
NO scheme description estimated indicative price
Quantities
SCM, prot:5fzd-5920/3920 main;110 vdc 55
SCM, prot:5fzd-5920/3920 backup;110 vdc 55
SCM, prot:5tm-5100 main;110 vdc 40
SCM, prot:5tm-5100 backup;110 vdc 40
SCM, prot:5tc-5100;110 vdc;9u(f), 4u(bp) 40
SCM, prot:5rf-5100;110 vdc;7u(f), 9u(bp) 75
SCM, prot:5cf-5100, inc, diff fo;110 vdc 20
SCM, prot:5bp-5100;110 vdc 2
SCM, prot:5bz-5600;110 vdc
Annexure a - scope of work for the kit
Components)
Vdc ((refer to annexure a - scope of work for
The kit components)
Antenna, pole, surge arrestor)
5.4 List of Engineering Drawings of the Approved Schemes – Table 3
No Drawing Description Drawing Reference Number and Revision
Hitachi Solution
Protection
5FZD32x0 D-DT-15011 - 15015_Rev 1
5FZD39x0 D-DT-15009 - 15010_Rev 2
5TM3100 D-DT-15207_Rev 0
5TM3200 D-DT-15210_Rev 2
5TC3200 D-DT-15302_Rev 1
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by
third parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 16
File name: EOI - Protection Schemes - Reissue
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
240-72663051 Rev 4
Identifier
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
5CF3100 D-DT-15408_Rev 2
5CF3150 D-DT-15411_Rev 2
5BS3100 D-DT-15409_Rev 1
5BS3150 D-DT-15412_Rev 2
5VT3100_5CPAT 3100 D-DT-15410_Rev 2
5VT3150_5CPAT 3150 D-DT-15413_Rev 2
5RF3100 and 5BC3100 D-DT-15407_Rev 2
5EG3100 D-DT-15503_Rev 0
5BP3500 and 5BP3700 D-DT-15609_Rev 0
5BZ3600 D-DT-15607_Rev 0
5BZ3800 D-DT-15606_Rev 0
5BZ3900 D-DT-15605_Rev 0
Automation
5AGW3100 D-DT-15950_Rev 3
5AGW3200 D-DT-15951_Rev 2
5AGW3300 D-DT-15952_Rev 2
No Drawing Description Drawing Reference Number and Revision
IST Solution
5FZD5820 D-DT-15016_Rev 1
5FZD5840 D-DT-15017_Rev 1
5FZD5900 D-DT-15014_Rev 1
5FZD5920 D-DT-15012_Rev 1
5FZD5940 D-DT-15013_Rev 1
5TM5100 D-DT-15208_Rev 1
5TM5200 D-DT-15209_Rev 2
5TC5200 D-DT-15302_Rev 0
5CF5100 D-DT-15415_Rev 1
5CF5150 D-DT-15418_Rev 1
5BS5100 D-DT-15416_Rev 1
5BS5150 D-DT-15419_Rev 1
5VT5100 D-DT-15417_Rev 1
5VT5150 D-DT-15420_Rev 1
5RF5100 D-DT-15414_Rev 1
5BP5100 D-DT-15614_Rev 1
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by
third parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 16
File name: EOI - Protection Schemes - Reissue
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
240-72663051 Rev 4
Identifier
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
5BP5150 D-DT-15615_Rev 1
5BP5200 D-DT-15616_Rev 1
5BZ5600 D-DT-15613_Rev 1
5BZ5800 D-DT-15612_Rev 1
5BZ5900 D-DT-15611_Rev 1
Automation
5AGW3100 D-DT-15953_Rev 4
5AGW5200 D-DT-15954_Rev 5
Refer to Annexure A for a detailed scope of work and Annexure B for a detailed Technical Evaluation
Criteria.
EOI submissions will not be considered unless they are received on or before the time and date as
indicated, signed by person(s) duly authorised to act on behalf of your company.
Eskom reserves the right to cancel this EOI process at any time prior to entering into any contract that
may result from this process and will not accept or incur any liability for such cancellation.
Eskom is not bound to accept any of the submissions, nor give reasons for any decisions in this
respect.
NOTE TO THE RESPONDENTS: Selection of the organization shall be made based on the details
submitted in the EOI. The offered solutions will be inspected for preliminary short-listing by
Eskom to determine market research for this requirement in order to develop a list of suppliers
able to provide the product. This list of suppliers may be used to inform a closed tender list.
This may include carrying out the inspection of the offered solution. Selected organizations will be
informed subsequently to submit the detailed offer and terms and conditions through a closed EOI
process.
Notwithstanding anything contained above, Eskom reserves the right to reject any or all Expression
Of Interest offers.
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by
third parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 16
File name: EOI - Protection Schemes - Reissue
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Document
240-72663051 Rev 4
Identifier
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
Yours faithfully
Name Designation Signature Date
Serole Boloko Senior Advisor Procurement
02 September 2026
Telephone number 051 404 2057 e-mail address [email protected]
Name Designation Signature Date
Kenosi Lekutle Procurement Manager 04/09/2026
Telephone number e-mail address
051 404 5716 [email protected]
Controlled Disclosure
When downloaded from the document management system, this document is uncontrolled and the responsibility rests with the user to
ensure it is in line with the authorized version on the system. No part of this document may be reproduced in any manner or form by
third parties without the written consent of Eskom Holdings SOC Ltd, © copyright Eskom Holdings SOC Ltd, Reg No 2002/015527/30
of 16
File name: EOI - Protection Schemes - Reissue
Template ID: 240-43921804 (Rev 7) Header and Footer portrait template
Methodology
Source: E3269DXGOUR - EOI - Protection Schemes - Reissue.pdf (EOI)Scope of work includes: review and take over responsibility for previously developed designs, modify previous designs where necessary, design schemes based on existing architecture to meet new requirements, manufacture, deliver and erect schemes including swing frame panels and PIU junction boxes, provide training as required, and provide technical product support, spares and service guarantees.
Experience & Qualifications
Source: E3269DXGOUR - EOI - Protection Schemes - Reissue.pdfexperience in the past 2 years with by Supplier
manufacturing of Protection Schemes,
have in configuring and integrating information to be
61850 devices across multiple schemes provided
in a bus as well as experience in
supporting protection schemes and
substation SCADA gateway devices in
the last 2 years. A table listing the
projects, customer, work description
showing evidence of the above shall be
provided.
resources (and qualifications, years of required information
experience) that will be available to to be provided.
support a possible 4-year contract in the
near future.
Quality Management
Source: E3269DXGOUR - EOI - Protection Schemes - Reissue.pdfEskom Holdings SOC Ltd (“Eskom”) invites you to submit an:
alone information-gathering and market-testing exercise, intended only to inform and assist Eskom’s further
deliberation and development of a strategy for the [Provision of Protection, Telecontrol Automation
Schemes, Swing Frame Panels and PIU Junction Boxes]. Eskom has delegated the responsibility for this
Pricing Schedule
Source: E3269DXGOUR - EOI - Protection Schemes - Reissue.pdf (EOI)Please provide costs assuming a 4-year production contract will be established with the estimated quantities indicated. Cost based on the included components as stipulated in Annexure A – Scope of Work. Estimated quantities include: Protection swing frame panel (100), Gateway internal swing frame panel (50), and other schemes as listed.
Health & Safety
Source: E3269DXGOUR - EOI - Protection Schemes - Reissue.pdfadversely affecting their approved design intent, functionality, performance, interoperability, safety,
2.1 Due to the specific need that this EOI process must fulfil, Eskom wishes to clarify that this invitation
is not intended to impede, amend, or replace any current or future procurement process that
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
5.3 List of Items to provide indicative pricing – Table 2
Please provide costs assuming a 4-year production contract will be established with the estimated
quantities indicated below. Please cost based on the included components as stipulated in Annexure
A – Scope of Work.
SCM, prot:5fzd-5920/3920 main;110 vdc 55
SCM, prot:5fzd-5920/3920 backup;110 vdc 55
SCM, prot:5tm-5100 main;110 vdc 40
SCM, prot:5tm-5100 backup;110 vdc 40
SCM, prot:5tc-5100;110 vdc;9u(f), 4u(bp) 40
SCM, prot:5rf-5100;110 vdc;7u(f), 9u(bp) 75
SCM, prot:5cf-5100, inc, diff fo;110 vdc 20
SCM, prot:5bp-5100;110 vdc 2
SCM, prot:5bz-5600;110 vdc
Contractual Terms
Source: E3269DXGOUR - EOI - Protection Schemes - Reissue.pdfworks/goods/services support of a previously developed range of Protection, Control and
Substation Automation Equipment (predominantly based on the Hitachi
(Pty) Ltd and IST range of products) with the associated swing frame
panels and PIU Junction Boxes to Eskom Distribution over a period of up
to four (4) years. It is Eskom’s expectation that the previous design intent
will be sustained, in terms of the overall system architecture, brand and
types of IEDs utilized, guarantees and the provision of training and product
support.
Deadline for submission 30 September 2026 At (South African 10:00 AM
Standard Time)
works/goods/services and support of a previously developed range of Protection, Control and
Substation Automation Equipment (predominantly based on the Hitachi
(Pty) Ltd and IST range of products) with the associated swing frame
panels and PIU Junction Boxes to Eskom Distribution over a period of
up to four (4) years. It is Eskom’s expectation that the previous design
intent will be sustained, in terms of the overall system architecture,
brand and types of IEDs utilized, guarantees and the provision of
training and product support.
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
reliability or compatibility with Eskom’s installed base. Where specific makes, models, part numbers or
configurations are essential for compatibility, respondents must confirm their ability to supply and
support them. Any proposed equivalent must be clearly identified and supported by sufficient technical
evidence for Eskom’s assessment and approval.
2.2 Eskom reserves the right, in its absolute discretion, at any stage and without notice, to terminate
further participation in the process by any Party, to select or disqualify any interested participant
from further engagement, to amend and/or terminate this EOI process or any future process
pursuant to this process.
2.3 This EOI is a market-testing exercise, intended only to inform and assist Eskom’s plans in pursuing
permanent solutions related to pertaining to engineering, supply, training and support of a
previously developed range of Protection, Control and Substation Automation Equipment
(predominantly based on the Hitachi (Pty) Ltd and IST range of products) with the
associated swing frame panels and PIU Junction Boxes to Eskom Distribution over a
period of up to four (4) years. It is Eskom’s expectation that the previous design intent will
be sustained, in terms of the overall system architecture, brand and types of IEDs utilized,
guarantees and the provision of training and product support for acquisition with Eskom
2.4 Any and/or all information submitted by any and/or all respondents may be used without the
necessity of acknowledging the source, and without such entity gaining any rights in respect of
such a solution, including but not limited to any intellectual property rights.
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
2.5 Any information provided pursuant to this EOI process, and any subsequent processes and/or
engagement is not confidential. Through making a submission a respondent accepts the terms
and conditions which governs this process.
2.6 All participants responding to this EOI process need to ensure that they have received all
information and remain solely responsible for satisfying themselves as to the information required
in responding hereto and are fully responsible for all costs incurred in relation hereto and under
no circumstances will any resultant cost be borne by Eskom.
2.7 Where any information or clarification is required, please do not hesitate to send an email to
Eskom Holdings SOC Ltd (“Eskom”) intends to initiate the commercial process to establish a contract
for the engineering, supply, training and support of a previously developed range of approved
Protection, Control and Substation Automation Schemes (predominantly based on the GE and Hitachi
protection relays) including the swing frame cabinets to house these schemes, to Eskom Distribution
over a period of up to four (4) years as per the following drawings. Note that the exact part and type
numbers are listed in the respective drawings. A table listing these drawings is provided in Section
5.4 below.
It is Eskom’s expectation that the previous design intent will be sustained, in terms of the overall
system architecture, functionality offered, brand and types of IEDs utilised (including part and type
numbers), guarantees and the provision of product support. The design details of the previously
developed and approved schemes and swing frame cabinets are captured in the engineering drawings
and base configurations which can be requested from Eskom and will be supplied (pdf’s) subject to
signature of a Non-Disclosure Agreement. These drawings will assist in understanding the scope and
in the completion of this EOI.
Expression Of Interest (EOI) Effective Date 17 June 2025
Review Date June 2030
EOI/EOI Number E3269DXGOUR
with one Supplier’s solution based predominantly on the Hitachi range of protection and automation
IEDs while the other Supplier’s solution was based predominantly on the GE range of protection and
automation IEDs. It was originally intended to extend these existing contracts for four years with the
respective suppliers, however due to challenges with the current contract and associated contracts,
this could not be concluded. It is Eskom’s intention to now re-establish these supply contracts with the
already developed solutions.
Pursuant to Eskom’s intended commercial process, the supplier will be required to:
functionality in devices offered but not yet used,
Eskom Distribution, as and when required, over a period of up to four (4) years,
5.1 EOI Returnables
document supplied in a contract can be
supported and all Eskom required
guarantees/warranties will be upheld by
the OEM.
provide a letter of confirmation from required
may result from this process and will not accept or incur any liability for such cancellation.
Requirements
Source: E3269DXGOUR - EOI - Protection Schemes - Reissue.pdf (EOI)Respondents must demonstrate their capability to reproduce and support the required schemes without adversely affecting their approved design intent, functionality, performance, interoperability, safety, and configurations. Any proposed equivalent must be clearly identified and supported by sufficient technical evidence for Eskom’s assessment and approval. Interested parties shall return information for the queries detailed, including: ability to supply and support Hitachi/GE equipment, OEM/VAR letters confirming support and warranties, experience in the past 2 years with similar equipment, details of technical resources and qualifications, training provided over the past 2 years covering protection, automation and networking, and confirmation of ability to supply schemes/equipment listed in Table 2.
Section
Source: E3269DXGOUR - EOI - Protection Schemes - Reissue.pdfRefer to Annexure A for a detailed scope of work and Annexure B for a detailed Technical Evaluation
adversely affecting their approved design intent, functionality, performance, interoperability, safety,
2.2 Eskom reserves the right, in its absolute discretion, at any stage and without notice, to terminate
Sets the constitutional standard for fair, equitable, transparent, competitive and cost-effective public procurement.
Relevant because this is a South African public-sector procurement opportunity.
Act 5 of 2000
Covers preferential procurement and preference-point systems used in public tenders.
Relevant because this is a South African public-sector procurement opportunity.
Act 12 of 2004
Supports anti-corruption controls and supplier integrity in procurement processes.
Relevant because this is a South African public-sector procurement opportunity.
Act 28 of 2024
Provides the national framework for public procurement across government.
Relevant because this is a South African public-sector procurement opportunity.
Act 2 of 2000
Supports access to tender records, award decisions and public-sector procurement information.
Relevant because this is a South African public-sector procurement opportunity.
Act 3 of 2000
Supports lawful, reasonable and procedurally fair administrative tender decisions.
Relevant because this is a South African public-sector procurement opportunity.
Address
Electronic submission via Eskom E- tendering portal. - VARIOUS - Bloemfontein - 9301
Source confidence
High source confidence
Official source
eTenders.gov.za
Documents found
3
Last checked
08 Sept 2026
AI status
Enhanced
Data conflicts
None detected
This tender has strong source evidence, including source metadata and supporting tender information synced from the government tender portal.
Tenders SA is not the issuing authority. All tenders are automatically synced from the official government tender portal. Always confirm final submission details, closing dates, briefing sessions, eligibility requirements, and documents on the official government portal before applying.
Key Personnel
Provinces Active
Industries
Learn how to submit a winning bid with these related articles
A strategic guide for medical equipment suppliers, maintenance companies, and healthcare technology providers bidding for tenders across South Africa's nine provincial health departments. Covers SAHPRA registration, OEM authorisation, service level agreements, and technical evaluation criteria.
A comprehensive guide to securing medical equipment maintenance tenders in South African public hospitals. Learn about SLA management, OEM certifications, and clinical engineering requirements.
A technical guide for manufacturers and distributors to supply high-end medical equipment and technology to Gauteng's largest public hospitals.
Guide to sports tenders in South Africa. Covers SRSA-funded facility maintenance, sports equipment supply, surfacing contracts, and tournament management opportunities.
💡 Want more tendering tips and strategies?
Explore Our BlogMedian Estimate
R 998 614
Range
Based on 25 comparable awarded tenders. Companies with similar profiles typically bid near the median.
* Estimates are based on historical data and do not guarantee actual award values.
Get deep intelligence on Manufacture of machinery and equipment n.e.c.. Unlock full pricing strategies, bid frequency, and historical win rates.