Broad-Based Black Economic Empowerment Act (B-BBEE Act)
Act 53 of 2003
Provides the empowerment-compliance context often used in public-sector supplier evaluation.
Relevant because this is a South African public-sector procurement opportunity.
Documents available on tender detail page
Tender Type
Request for Bid(Open-Tender)
Delivery Location
GAUTENG - GAUTENG - GAUTENG - 1682
Organization Type
GOVERNMENT
Published
23 Nov 2026
OCDS Reference
ocds-9t57fa-179532
ESKOM requires the supply and delivery of circuit breakers across its gauteng cluster on an as-and-when-required basis for a 60-month period. Bidders must submit a signed supplier declaration of interest (form 240-59385360, rev 3) under oath, disclosing any ESKOM employment or directorship held by the bidder or its interest holders, any close family or associate relationship with an ESKOM employee or director involved in the procurement, and any business courtesy exchanged with an ESKOM employee or director in the past 12 months. The most consequential bidder consideration is that a false declaration may result in action against the supplier or the signatory personally, and ESKOM employees and directors are prohibited from financially benefiting from the procurement.
Returnable form: Supplier Declaration of Interest (form 240-59385360, Rev 3) must be completed, signed and submitted with the bid.
Conflict of interest: Bidders must declare whether they or any interest holder (shareholder, director, member, partner, line manager or employee) is employed by Eskom or serves as an Eskom director.
Relationship disclosure: Bidders must declare any close family or associate relationship between persons acting for the supplier and an Eskom employee or director who may participate in the procurement process.
Business courtesies: Bidders must declare any business courtesy given to or received from an Eskom employee or director in the last 12 months.
Oath and consequences: The declaration is made under oath; a false declaration may lead to action against the supplier or the signatory personally.
Prohibition: Eskom employees and directors may not engage in private work for or financially benefit from the supplier awarded this procurement.
Closing date: Bids close on 15 December 2026 at 08:00; late or incomplete submissions, including a missing declaration, may be rejected.
Continue with tenders sharing this issuer, category, or province.
Browse categories with current opportunities in this area.
Compare tender activity across provinces.
Explore organisations currently publishing tenders.
Tools and research to help you assess opportunities.
Return to this tender’s issuing organisation, province, or category.
Continue with tenders sharing this issuer, category, or province.
Browse categories with current opportunities in this area.
Compare tender activity across provinces.
Explore organisations currently publishing tenders.
Tools and research to help you assess opportunities.
Date & Time
Tuesday, 15 December 2026 - 10:00
Venue
https://teams.microsoft.com/meet/3377028059554911?p=cZIFUv7s6uZ8bsN7zo
Categories
Request for Bid(Open-Tender)
GAUTENG - GAUTENG - GAUTENG - 1682
Recommended Certifications
Having these can improve your winning chances: SABS Product Certification, NRCS Certification
AI Document Analysis Stages
Submission Guidelines
Source: Supplier Declaration of Interest Template(3).docx (unknown)23 Nov
2026
Tender Published
Tender was published
15 Dec
2026
Closing Date
Tender closing date
These references help suppliers understand the public-procurement framework around this opportunity. They are generated from the tender category, issuing organisation type and procurement context.
These rules commonly apply to South African public-sector procurement.
Act 53 of 2003
Provides the empowerment-compliance context often used in public-sector supplier evaluation.
Relevant because this is a South African public-sector procurement opportunity.
Act 108 of 1996 (s217)
This is general procurement context, not legal advice. Always verify requirements in the official tender documents and issuing authority notices.
Annex C.pdf
Annex D.pdf
SAFETY Tender Evaluation Criteria.pdf
Supply and delivery of circuit breakers to Eskom's Gauteng Cluster on an as-and-when-required basis over a 60-month period. The work is classified as low risk, with occupational health and safety documentation required from bidders.
Supplier Declaration of Interest Template(3).docx
Supply and delivery of circuit breakers to Eskom's Gauteng Cluster on an as-and-when-required basis over a 60-month period. Bidders must submit a signed Supplier Declaration of Interest covering Eskom employment, close family and associate relationships, business courtesies and other consulting work.
E-tendering Help Manual for supplier - 27 January 2025 (1).docx
Supply and delivery of circuit breakers to Eskom's Gauteng Cluster on an as-and-when-required basis over a 60-month period. Bidders submit their offers electronically through Eskom's eTendering portal.
Annexure J - SBD 4 - Tenderer's Disclosure - 20 April 2026.docx
Supply and delivery of circuit breakers to Eskom's Gauteng Cluster on an as-and-when-required basis over a 60-month period. Bidders submit an offer against the invitation to tender, supported by a completed tenderer's disclosure declaration.
TECHNICAL 240-56227516 LV Switchgear.pdf
Supply and delivery of circuit breakers in the Gauteng Cluster on an as-and-when-required basis for a period of 60 months. The equipment must be factory-built, design-verified low-voltage switchgear and controlgear assemblies rated up to and including 1000 V AC or 1500 V DC, conforming to SANS 61439 and SANS 61641.
Annex E.pdf
240-62044728 (Rev. 11) Eskom Holdings Ltd Standard Conditions of Tender.pdf
Supply and delivery of circuit breakers to Eskom's Gauteng cluster on an as-and-when-required basis over a 60-month period. The contract is a framework arrangement with fixed rates and prices for its duration.
Non-Disclosure Agreement (NDA) Vendors.docx
Supply and delivery of circuit breakers to Eskom's Gauteng Cluster on an as-and-when-required basis over a 60-month period. Bidders must sign a confidentiality agreement before receiving project information.
TECHNICAL 3034.pdf
Supply and delivery of miniature circuit breakers and moulded case circuit breakers to the Gauteng Cluster on an as-and-when-required basis over 60 months. The circuit breakers must meet Eskom's technical specification D-DT-3034, covering current ratings from 40A to 800A across single-pole and triple-pole configurations.
Cuicut Breakers Thresholdsbd6.2 Annah .doc
Supply and delivery of circuit breakers in the Gauteng Cluster on an as-and-when-required basis over a 60-month period. Bidders must meet a 100% local content threshold for circuit breakers under the switchgear designation.
Circuit Breaker SDL&I Undewrtaking Annah.docx
Supply and delivery of circuit breakers to Eskom's Gauteng Cluster on an as-and-when-required basis over 60 months. The contract carries mandatory socio-economic development obligations covering B-BBEE, localisation, subcontracting, skills development, job creation and supplier development.
TECHNICAL D-DT-3034 - Tech Schedule.xlsx
Supply and delivery of miniature circuit breakers (MCBs) and moulded-case circuit breakers (MCCBs) to Eskom's Gauteng Cluster on an as-and-when-required basis over a 60-month period. Bidders must offer circuit breakers compliant with Eskom Buyer's Guide DDT-3034 and Eskom specification 240-56227516, completing a unique technical Schedule A and Schedule B for each of the 13 listed SAP numbers.
E-Tenderers E-Tendering Training Acknowledgement Form - 27 January 2025 (1).docx
Supply and delivery of circuit breakers to Eskom in the Gauteng Cluster on an as-and-when-required basis over a 60-month period. Bidders submit through Eskom's e-Tendering solution and must confirm they can operate it.
Invitation to Tender (ITT) Supply and Delivery Circuit Breakers.pdf
Supply and delivery of circuit breakers to Eskom's Gauteng Cluster on an as-and-when-required basis over a 60-month period. Bidders may tender for pole-top box MCBs, underground breakers (MCBs and MCCBs), or both categories, and technically compliant products may be added to Eskom's Technically Evaluated and Acceptable Products (TEAP) database.
TECHNICAL 240-130277632 MCBs and MCCBs evaluation criteria rev 2.pdf
Supply and delivery of miniature circuit breakers (MCBs) and moulded case circuit breakers (MCCBs) to Eskom's Gauteng Cluster on an as-and-when-required basis over 60 months. Bidders may tender for pole top box MCBs, underground MCBs and MCCBs, or either category, and submissions are evaluated on the items offered.
QUALITY FORM A 240-68099512 (Rev 9) Form A Tender & Contract Quality Requirements Cat 2 (1).pdf
Supply and delivery of circuit breakers in the Gauteng Cluster on an as-and-when-required basis for a period of 60 months. Bidders must meet Eskom's tender and contract quality requirements, including ISO 9001 alignment and Category 2 pre-contract award quality requirements.
Environmental Specifications_Delivery of Circuit Breakers_FY2627.pdf
Supply and delivery of circuit breakers to Eskom's Gauteng Cluster on an as-and-when-required basis over a 60-month period. The scope covers the manufacture, supply and delivery of the circuit breakers.
BOQ Circuit Breakers.xlsx
Supply and delivery of circuit breakers to the Gauteng cluster on an as-and-when-required basis over a 60-month period. The schedule covers miniature and moulded-case circuit breakers from 40A to 600A across 1-pole and 3-pole configurations at 230V and 400V, with breaking capacities of 5kA and 20kA.
QUALITY REQUIREMENTS 240-12248652 (Rev 7)_List of Tender Returnables Cat 2.pdf
Eskom requires the supply and delivery of circuit breakers in the Gauteng Cluster on an as and when required basis over a 60-month period. Bidders must demonstrate a compliant quality management system and submit a draft Contract Quality Plan, Quality Control Plan and Inspection and Test Plan specific to the scope.
SAFETY Annexure B.pdf
Supply and delivery of circuit breakers to Eskom's Gauteng Cluster on an as-and-when-required basis over a 60-month period. Bidders must also accept Eskom's occupational health and safety legal and other requirements, including management and oversight of their own contractors and suppliers.
Eskom General Conditions of Purchase - 31 May 2024.pdf
Eskom requires the supply and delivery of circuit breakers in the Gauteng cluster on an as-and-when-required basis over a 60-month period. The contract is governed by Eskom's General Conditions of Purchase, which set out payment, delivery, warranty, rejection and termination terms.
Authorisation Form.pdf
Supply and delivery of circuit breakers to Eskom's Gauteng Cluster on an as-and-when-required basis over a 60-month period. Bidders must submit an Authorisation Form confirming the status of their organisation and the authority of the named signatory to bind the bidder.
NEC The provision of manufacturing and supply of various Circuit Breakers.pdf
Supply and delivery of circuit breakers to Eskom's Gauteng Cluster on an as-and-when-required basis over a 60-month period, under an NEC3 Supply Contract (SC3). Delivery is to be arranged by Rotran or by the supplier where feasible, with each purchase order setting its own delivery date.
To download these documents and access AI-powered analysis, visit the main tender page.
Organization
EskomWin Eskom tenders with AI Tender Matching, technical document analysis, compliance scoring, and structured bid support for energy and engineering contracts.
Matched by category & region
Free guidance to prepare before you bid
Not sure if your business is ready for this tender? Check CSD, CIDB, and B-BBEE requirements, run a readiness assessment, and move from opportunity to submission.
Open Supplier Readiness HubWe refine every tender document through these stages so you can brief your team and prepare your bid with confidence. Anything marked as "in progress" will be upgraded automatically — no action required from you.
Returnable document
Compliance Requirements
Source: Supplier Declaration of Interest Template(3).docx (unknown)Conflict of interest
Description
Source: TECHNICAL 240-56227516 LV Switchgear.pdfThe standard specifies Eskom's requirements for factory-built, design-verified low-voltage switchgear and controlgear assemblies for voltages up to 1 000 V AC or 1 500 V DC, for indoor or outdoor installation.
Evaluation Criteria
Source: TECHNICAL 240-56227516 LV Switchgear.pdf (unknown)Design verification
Routine verification
Component certification
Technical Specifications
Source: TECHNICAL 240-56227516 LV Switchgear.pdf (unknown)Scope
Construction
Insulation and clearances
Degrees of protection
Forms of internal separation
Finish and coating
Doors and covers
Functional units
Busbars
Wiring
Conductor identification
Control wiring terminations
Outgoing cable termination
Control power supply
Nameplates and labels
Engineering drawings
Manuals
Transportation
Compliance Requirements
Source: TECHNICAL 240-56227516 LV Switchgear.pdf (unknown)Standards compliance
Health & Safety
Source: TECHNICAL 240-56227516 LV Switchgear.pdfSafety and arc protection
Description
Source: E-tendering Help Manual for supplier - 27 January 2025 (1).docxEskom's eTendering portal is a web-based system through which suppliers upload bid documents for tenders advertised on the Tender Bulletin.
It replaces physical delivery of tender documents to Eskom tender offices.
Suppliers must register before access is granted; a one-time PIN is sent to the registered cell phone and email address at each login.
A CSD number is required to use the system.
The portal also supports closed tenders sent directly to selected suppliers, who receive a private bidding link by email.
Submission Guidelines
Source: E-tendering Help Manual for supplier - 27 January 2025 (1).docx (unknown)Submission channel: Eskom eTendering portal at https://eTendering.eskom.co.za (linked from the Tender Bulletin at https://tenderbulletin.eskom.co.za).
Registration: suppliers must register on eTendering before uploading; a CSD number is required for access, contact numbers must use the +27 prefix, and registration includes a CAPTCHA check.
Login: registered email address and password, followed by a one-time PIN sent to the registered cell phone and email.
Upload process: select the tender reference number, create a new submission, add each file under the correct category (technical, commercial, finance), then finalise the submission.
File size limits: no single file may exceed 50MB; the combined upload may not exceed 900MB.
Finalisation: the submission is only complete once the finalise and close action is confirmed; a timestamped confirmation page and an email listing all submitted documents are issued.
Record keeping: retain the submission confirmation email and submission ID for any later enquiry.
System problems: contact the buyer responsible for the published tender.
Technical Specifications
Source: E-tendering Help Manual for supplier - 27 January 2025 (1).docx (unknown)The eTendering portal is Eskom's web-based replacement for physical delivery of tender documents to Eskom tender offices.
Suppliers upload bid documents electronically instead of submitting them at an Eskom office.
The portal also carries closed tenders that are not advertised on the Tender Bulletin; invited suppliers receive a private bidding link by email.
Access requires supplier registration and a CSD number.
Each login requires a one-time PIN delivered to the registered cell phone and email address.
Uploaded documents must be filed under the correct category (technical, commercial, finance).
The portal is compatible with most web browsers; Microsoft Edge is recommended.
Compliance Requirements
Source: E-tendering Help Manual for supplier - 27 January 2025 (1).docx (unknown)CSD registration: a valid CSD number is mandatory to gain access to the eTendering system and upload a bid.
Supplier registration on eTendering is required before any submission; contact numbers must be captured in +27 format.
Submission Guidelines
Source: Annexure J - SBD 4 - Tenderer's Disclosure - 20 April 2026.docx (unknown)Returnable form: SBD 4 (Tenderer's Disclosure) — must be completed, signed and submitted with the bid; it discloses state employment, relationships with the procuring institution and interests in other enterprises, and certifies independent bid determination.
Evaluation Criteria
Source: Annexure J - SBD 4 - Tenderer's Disclosure - 20 April 2026.docx (unknown)Bidders listed on the Register for Tender Defaulters or the List of Restricted Suppliers are automatically disqualified. A bid may be rejected or action taken under PFMA SCM Instruction 03 of 2021/22 if the SBD 4 disclosure is found to be false.
Compliance Requirements
Source: Annexure J - SBD 4 - Tenderer's Disclosure - 20 April 2026.docx (unknown)SBD 4 (Tenderer's Disclosure): discloses whether any director, shareholder, member or controlling person is employed by the state, has a relationship with anyone at Eskom, or holds an interest in another related enterprise; a false or incomplete disclosure disqualifies the bid.
Bidders must not appear on the Register for Tender Defaulters or the List of Restricted Suppliers.
Description
Source: Non-Disclosure Agreement (NDA) Vendors.docxEskom Holdings SOC Ltd requires suppliers of circuit breakers for the Gauteng Cluster on an as-and-when-required basis over a 5-year period. This confidentiality agreement governs the exchange of information between Eskom and the supplier in relation to that project.
Contact Information
Source: Non-Disclosure Agreement (NDA) Vendors.docx (unknown)Eskom contact
Eskom physical address
Megawatt Park
Maxwell Drive
Sunninghill
Sandton
Eskom postal address
PO Box 1091
Johannesburg
2000
Submission Guidelines
Source: Non-Disclosure Agreement (NDA) Vendors.docx (unknown)Returnable document
Submission
Compliance Requirements
Source: Non-Disclosure Agreement (NDA) Vendors.docx (unknown)Confidentiality obligations
Description
Source: TECHNICAL 3034.pdfSupply and delivery of miniature and moulded case circuit breakers to the Gauteng cluster on an as-and-when-required basis for 60 months. The technical schedule lists 13 items identified by Eskom SAP material numbers, all conforming to Eskom drawing D-DT-3034.
Technical Specifications
Source: TECHNICAL 3034.pdf (unknown)Scope: supply and delivery of miniature and moulded case circuit breakers for the Gauteng cluster, on an as-and-when-required basis over 60 months.
Miniature circuit breakers (DIN rail mounted, hydraulic magnetic, no exposed live parts, compliant with clause 8.2 of IEC 60898, Eskom drawing D-DT-3034):
Moulded case circuit breakers (triple pole, 400 V, suitable for isolation, standard tripping curve, electronic/hydraulic magnetic operating mechanism, electronic settable MCCB with Eskom-required current rating sticker/label, Eskom drawing D-DT-3034):
Standards and identification:
Description
Source: TECHNICAL D-DT-3034 - Tech Schedule.xlsxSupply and delivery of miniature circuit breakers and moulded-case circuit breakers to the Gauteng cluster on an as-and-when-required basis for 60 months, in accordance with Eskom Buyer's Guide DDT-3034 and Eskom specification 240-56227516.
Submission Guidelines
Source: TECHNICAL D-DT-3034 - Tech Schedule.xlsx (unknown)Returnable documents — all must be completed, signed and submitted with the bid:
Format: all documentation must also be supplied electronically.
Evaluation Criteria
Source: TECHNICAL D-DT-3034 - Tech Schedule.xlsx (unknown)Compliance-based assessment against the Eskom Buyer's Guide and specification:
Technical Specifications
Source: TECHNICAL D-DT-3034 - Tech Schedule.xlsx (unknown)Scope: supply and delivery of miniature circuit breakers (MCBs) and moulded-case circuit breakers (MCCBs) to the Gauteng cluster on an as-and-when-required basis over 60 months.
SAP numbers and descriptions (one schedule per number):
Technical particulars to be declared per item:
Standards: SANS 60947-1, SANS 60947-2, SANS 60947-5-1, SANS 556, SANS 10142-1 and VC8036.
Tests required on MCCBs: type test, temperature-rise, dielectric properties, rated short-time withstand current (1 s), tripping limits and characteristic, short-circuit breaking capacity, overload performance, performance of integrally fused circuit breakers, operational performance capability, electromagnetic compatibility and calibration of releases.
Compliance Requirements
Source: TECHNICAL D-DT-3034 - Tech Schedule.xlsx (unknown)Technical compliance
Documentation
Description
Source: TECHNICAL 240-130277632 MCBs and MCCBs evaluation criteria rev 2.pdfPurpose
Scope
Reference documents
Responsibilities
Submission Guidelines
Source: TECHNICAL 240-130277632 MCBs and MCCBs evaluation criteria rev 2.pdf (unknown)Returnable documents
Disqualification risks
Evaluation Criteria
Source: TECHNICAL 240-130277632 MCBs and MCCBs evaluation criteria rev 2.pdf (unknown)Evaluation stages
Technical evaluation score = 80% (Level 1) + 20% (Level 2).
Bidders may tender for pole top box MCBs, underground MCBs and MCCBs, or either; evaluation is done on the items tendered.
No factory evaluation will be conducted; inspection of items will be at the warehouses of successful tenderers. Samples may be requested for inspection before award.
Technical Specifications
Source: TECHNICAL 240-130277632 MCBs and MCCBs evaluation criteria rev 2.pdf (unknown)Scope
Technical requirements
Quality Management
Source: TECHNICAL 240-130277632 MCBs and MCCBs evaluation criteria rev 2.pdfQuality requirements
Compliance Requirements
Source: TECHNICAL 240-130277632 MCBs and MCCBs evaluation criteria rev 2.pdf (unknown)Mandatory technical compliance
Health & Safety
Source: TECHNICAL 240-130277632 MCBs and MCCBs evaluation criteria rev 2.pdfNo health and safety requirements are specified in this document. The content relates to technical compliance and evaluation criteria for circuit breakers.
Section
Source: TECHNICAL 240-130277632 MCBs and MCCBs evaluation criteria rev 2.pdfTechnical evaluation is split into two levels:
Technical evaluation score = 80% (Level 1) + 20% (Level 2).
Bidders may tender for pole top box MCBs, underground MCBs and MCCBs, or either; evaluation is done on the items tendered.
Description
Source: QUALITY FORM A 240-68099512 (Rev 9) Form A Tender & Contract Quality Requirements Cat 2 (1).pdfSupply and delivery of circuit breakers in the Gauteng cluster on an as-and-when-required basis for a period of 60 months.
Quality requirements
Submission Guidelines
Source: QUALITY FORM A 240-68099512 (Rev 9) Form A Tender & Contract Quality Requirements Cat 2 (1).pdf (unknown)Returnable document
Form requirements
Evaluation Criteria
Source: QUALITY FORM A 240-68099512 (Rev 9) Form A Tender & Contract Quality Requirements Cat 2 (1).pdf (unknown)Quality compliance is assessed against the completed Form A.
Pre-contract award
ISO 9001 alignment
Technical Specifications
Source: QUALITY FORM A 240-68099512 (Rev 9) Form A Tender & Contract Quality Requirements Cat 2 (1).pdf (unknown)Supply and delivery of circuit breakers to the Gauteng cluster on an as-and-when-required basis over a 60-month period.
Quality scope
Methodology
Source: QUALITY FORM A 240-68099512 (Rev 9) Form A Tender & Contract Quality Requirements Cat 2 (1).pdfISO 9001 clauses applicable
Quality principles applicable
Quality Management
Source: QUALITY FORM A 240-68099512 (Rev 9) Form A Tender & Contract Quality Requirements Cat 2 (1).pdfQuality requirements
Iso 9001
Form A
Compliance Requirements
Source: QUALITY FORM A 240-68099512 (Rev 9) Form A Tender & Contract Quality Requirements Cat 2 (1).pdf (unknown)Quality management
Post-award obligations
Section
Source: QUALITY FORM A 240-68099512 (Rev 9) Form A Tender & Contract Quality Requirements Cat 2 (1).pdfQuality compliance is assessed through Form A.
Pre-contract award
Post-contract award
Iso 9001
Technical Specifications
Source: BOQ Circuit Breakers.xlsx (unknown)Scope
Item schedule (material number — description)
Pricing basis
Financial Requirements
Source: BOQ Circuit Breakers.xlsx (unknown)Pricing format
Description
Source: Invitation to Tender (ITT) Supply and Delivery Circuit Breakers.pdfEskom Holdings SOC Ltd invites tenders for the supply and delivery of circuit breakers to the Gauteng Cluster on an as-and-when-required basis over 60 months.
Products that pass technical evaluation may be added to Eskom's Technically Evaluated and Acceptable Products (TEAP) database.
Tender documents are issued free of charge.
Submitting a tender is deemed acceptance of Eskom's Standard Conditions of Tender, available at www.eskom.co.za.
The Tender Data takes precedence over the Standard Conditions of Tender where the two conflict.
All queries must be addressed in writing to the Eskom Representative only.
Important Dates
Source: Invitation to Tender (ITT) Supply and Delivery Circuit Breakers.pdf (TENDER)Clarification meeting (non-compulsory)
Closing
Clarification queries
Tender validity
Contact Information
Source: Invitation to Tender (ITT) Supply and Delivery Circuit Breakers.pdf (TENDER)Eskom Representative
Procurement Manager
Enquiries
Fraud and corruption reporting
Submission
Submission Guidelines
Source: Invitation to Tender (ITT) Supply and Delivery Circuit Breakers.pdf (TENDER)Submission method: electronic upload via the Eskom Tender Bulletin e-tendering page only.
Format: all documents in PDF; the price list must also be PDF.
Upload limits: 500 MB per document; 4 GB total submission.
No ZIP or compressed files; no hard copies accepted.
Upload folders: Technical, Commercial, Financial and Other.
Resubmission: only the latest uploaded version is considered; earlier submissions become void.
The submission status must show as complete.
Returnable documents required at closing (disqualifiable if missing, incomplete or unsigned):
Returnables that score zero if omitted (no disqualification):
Returnables required before contract award:
Disqualification risks:
Evaluation Criteria
Source: Invitation to Tender (ITT) Supply and Delivery Circuit Breakers.pdf (TENDER)Evaluation stages, in order:
Technical evaluation (functionality)
Price and preference points (90/10 system)
Price evaluation basis
Objective criteria
Contractual requirements and SHEQ
Technical Specifications
Source: Invitation to Tender (ITT) Supply and Delivery Circuit Breakers.pdf (TENDER)Scope
Product categories
Technical standards
Inspection
Cataloguing and labelling
Contract form
Pricing Schedule
Source: Invitation to Tender (ITT) Supply and Delivery Circuit Breakers.pdfPricing schedule or bill of quantities: contained in the NEC pack; submit a completed version in PDF.
Where cataloguing applies, the pricing schedule must include a cataloguing line item; Eskom pays for cataloguing.
Prices are evaluated inclusive of VAT, corrected for arithmetic errors and excluding contingencies.
Unconditional discounts are scored; conditional discounts are applied only at payment.
Upload limits: 500 MB per document and 4 GB total submission.
The completed pricing schedule is a returnable required before contract award.
Financial Requirements
Source: Invitation to Tender (ITT) Supply and Delivery Circuit Breakers.pdf (TENDER)Pricing
Payment terms
Performance security
Financial analysis (before award)
Risk mitigation Eskom may require
Compliance Requirements
Source: Invitation to Tender (ITT) Supply and Delivery Circuit Breakers.pdf (TENDER)Eligibility
Mandatory contractual requirements (before award)
Sheq
Not applicable
Health & Safety
Source: Invitation to Tender (ITT) Supply and Delivery Circuit Breakers.pdfSHEQ compliance is a legal and contractual requirement for the contract and must be legally valid and in place.
Safety, quality and environmental requirements are set out in separate packs and are applicable to this contract.
SHEQ is not an evaluation criterion; it is assessed after technical ranking and before award.
The recommended bidder has one opportunity, within 7 working days after the first evaluation, to resubmit requirements not fully met.
Failure to meet SHEQ requirements by the deadline may render the bid non-responsive and ineligible for award.
Agreed mitigating factors become contract terms; if mitigation is unsuitable or risk too high, the award may go to another bidder.
Environmental
Source: Invitation to Tender (ITT) Supply and Delivery Circuit Breakers.pdfEnvironmental requirements are specified in the separate environmental specification and must be met as a contractual obligation.
Environmental documentation is a returnable required before contract award.
Environmental compliance is assessed after technical ranking and before award, with one resubmission window of up to 7 working days.
Contractual Terms
Source: Invitation to Tender (ITT) Supply and Delivery Circuit Breakers.pdfContract form: NEC3 Supply Contract.
Contract period: 60 months, on an as-and-when-required basis.
Payment terms:
Performance security: not applicable.
Risk mitigation Eskom may require: a performance bond from an Eskom Treasury pre-approved financial institution, a parent company guarantee supported by the parent's latest approved financial statements, a reduced contract scope, or payment on delivery of a milestone activity or milestone goods.
Subcontracting to a subsidiary is discouraged as potential fronting; any such subcontract must be declared in the tender.
Eskom may negotiate with preferred bidders where tendered prices are not market-related.
Tenders that do not meet Eskom's contractual requirements are not evaluated further.
Section
Source: Invitation to Tender (ITT) Supply and Delivery Circuit Breakers.pdfTechnical evaluation is split into two levels:
Price and specific goals (90/10 system):
Submission Guidelines
Source: Authorisation Form.pdf (unknown)Returnable document — Authorisation Form (Eskom 240-15811258 Rev 2):
Compliance Requirements
Source: Authorisation Form.pdf (unknown)Authority to sign
Joint ventures
Description
Source: 240-62044728 (Rev. 11) Eskom Holdings Ltd Standard Conditions of Tender.pdfSupply and delivery of circuit breakers to the Gauteng cluster on an as and when required basis over a 60-month period. The enquiry documents set out the specification and works information; the Acknowledgement Form must state whether the tender covers the whole or part of the works, services or supply.
Important Dates
Source: 240-62044728 (Rev. 11) Eskom Holdings Ltd Standard Conditions of Tender.pdf (TENDER)Closing
Compulsory briefing or site visit
Clarification queries
Contact Information
Source: 240-62044728 (Rev. 11) Eskom Holdings Ltd Standard Conditions of Tender.pdf (TENDER)Eskom Representative
Fraud and corruption reporting
Submission address
Submission Guidelines
Source: 240-62044728 (Rev. 11) Eskom Holdings Ltd Standard Conditions of Tender.pdf (TENDER)Submission method
Returnable documents
Disqualification risks
Evaluation Criteria
Source: 240-62044728 (Rev. 11) Eskom Holdings Ltd Standard Conditions of Tender.pdf (TENDER)Evaluation stages
Arithmetic checking
Reverse e-auction
Technical Specifications
Source: 240-62044728 (Rev. 11) Eskom Holdings Ltd Standard Conditions of Tender.pdf (TENDER)Scope
Delivery and capacity
Standards and compliance
Quality Management
Source: 240-62044728 (Rev. 11) Eskom Holdings Ltd Standard Conditions of Tender.pdfSheq
Tender documents
Cost of tendering
Pricing Schedule
Source: 240-62044728 (Rev. 11) Eskom Holdings Ltd Standard Conditions of Tender.pdfPricing
Insurance
Alterations and alternatives
Clarification and correction
Arithmetic checking
Ranking
Financial Requirements
Source: 240-62044728 (Rev. 11) Eskom Holdings Ltd Standard Conditions of Tender.pdf (TENDER)Pricing
Security for performance
Insurance
Cost of tendering
Compliance Requirements
Source: 240-62044728 (Rev. 11) Eskom Holdings Ltd Standard Conditions of Tender.pdf (TENDER)Eligibility
Statutory and registration requirements
B-bbee
Contract skills and participation
Grounds for rejection
Health & Safety
Source: 240-62044728 (Rev. 11) Eskom Holdings Ltd Standard Conditions of Tender.pdfStatutory compliance
SHEQ proof
CIDB
Skills and participation
Evaluation and rejection
Contractual Terms
Source: 240-62044728 (Rev. 11) Eskom Holdings Ltd Standard Conditions of Tender.pdfCommunication
Eskom's rights
Tender validity
Confidentiality and copyright
Packaging
Compulsory meetings
Section
Source: 240-62044728 (Rev. 11) Eskom Holdings Ltd Standard Conditions of Tender.pdfBasic compliance is assessed before detailed evaluation; failure renders a tender non-responsive. Where functionality is a criterion, tenders must meet the minimum threshold in the Tender Data to proceed. Financial statements are assessed for financial risk, and Eskom may disqualify a tender where risk is too high or mitigating factors are insufficient. Price is evaluated against the Tender Data criteria, taking into account CPA, forex, commodity increases, discounts, NPV and forecasted invoicing rates. Specific Goals are scored on supporting documentation; a tenderer that fails to meet them or submit proof by the closing deadline scores zero for Specific Goals and receives 80 or 90 points for Price under the PPPFA allocation. Price and Specific Goals scores are added and suppliers ranked highest to lowest. A contract may be awarded to a tenderer that did not score the highest points only under Section 2(1)(f) of the PPPFA Act, where objective criteria are stipulated in the tender documents; functionality and contractual requirements may not be used as objective criteria.
Description
Source: NEC The provision of manufacturing and supply of various Circuit Breakers.pdfSupply and delivery of circuit breakers in the Gauteng Cluster on an as and when required basis for a period of 60 months.
Contract based on NEC3 Supply Contract (SC3).
Documents include: Part C1 Agreements & Contract Data, Part C2 Pricing Data, Part C3 Scope of Work.
Important Dates
Source: NEC The provision of manufacturing and supply of various Circuit Breakers.pdf (unknown)Closing date: 15 December 2026 at 08:00.
Briefing session: Not specified.
Site visit: Not specified.
Clarification deadline: Not specified.
Contact Information
Source: NEC The provision of manufacturing and supply of various Circuit Breakers.pdf (unknown)Supply Manager:
Purchaser:
Submission address: Not specified.
Submission Guidelines
Source: NEC The provision of manufacturing and supply of various Circuit Breakers.pdf (unknown)Submission method: Not specified in the document.
Returnable documents:
Disqualification risks:
Evaluation Criteria
Source: NEC The provision of manufacturing and supply of various Circuit Breakers.pdf (unknown)Evaluation stages:
Minimum qualifying score: Not specified.
Preference point system: Not specified.
Technical Specifications
Source: NEC The provision of manufacturing and supply of various Circuit Breakers.pdf (unknown)Scope: Supply and delivery of circuit breakers in the Gauteng Cluster on an as and when required basis for a period of 60 months.
Delivery: By Rotran or the supplier where feasible.
Delivery place: Not applicable.
Defects liability:
Testing and certification: Compliance with Eskom specifications, IEC/SANS standards, safety, environmental, and quality requirements is mandatory.
Risk register includes: delay on delivery, changes to lead time, damages to goods, poor quality checks.
Local suppliers: approximately 12 local suppliers and manufacturers; at least 9 international suppliers.
Quality Management
Source: NEC The provision of manufacturing and supply of various Circuit Breakers.pdfDefects date: 52 weeks after delivery.
Defect correction period: 4 weeks (6 weeks for imported products; 3 weeks for programming including testing).
Defect access period: 7 days.
Quality requirements are applicable and attached separately.
Compliance with Eskom specifications, IEC/SANS standards, safety, environmental, and quality requirements is mandatory.
Poor quality checks on goods are a risk.
Limited testing and certification capacity may extend lead times.
Pricing Schedule
Source: NEC The provision of manufacturing and supply of various Circuit Breakers.pdfPricing data: Part C2 Pricing Data.
Price schedule: To be completed by supplier (C2.2).
Pricing assumptions: C2.1.
Tendered total of the Prices: Rate-based.
VAT: 15%.
Assessment interval: Upon delivery of each batch.
Payment terms: 30 days (contracts below R50 million) or 60 days (contracts above R50 million) from tax compliant invoice.
Performance bond: 40% of total contract value.
Delay damages: R5,000 per day.
Price adjustment for inflation: Option X1, proportions to be provided by suppliers and concluded in negotiations.
Financial Requirements
Source: NEC The provision of manufacturing and supply of various Circuit Breakers.pdf (unknown)Pricing: Rate-based pricing; offered total of the Prices exclusive of VAT is rate-based.
Payment terms:
Performance bond: 40% of the total contract value.
Delay damages: R5,000 per day for late delivery or changes in lead time.
Insurance:
Financial analysis: Required; submission of audited financial statements.
Risk mitigation may include: performance bond from Eskom Treasury pre-approved financial institution, parent company guarantee, reduced contract, or milestone payments.
Compliance Requirements
Source: NEC The provision of manufacturing and supply of various Circuit Breakers.pdf (unknown)CSD registration: Proof of National Treasury Central Supplier Database (CSD) with tax compliant status at contract award.
B-BBEE: Valid B-BBEE certificate or sworn affidavit.
Tax compliance: Tax Compliance Status (TCS) e-filing PIN from SARS.
Letter of Good Standing: Valid Letter of Good Standing with the compensation body (FEMA/RMA).
SHEQ: Safety, Quality, and Environmental requirements are applicable and attached separately; compliance must be demonstrated.
SDL&I: See attached SDL&I requirements.
Financial analysis: Submission of financial statements required.
CIDB: Not applicable.
Local content: Not specified.
Health & Safety
Source: NEC The provision of manufacturing and supply of various Circuit Breakers.pdfSupplier must take all reasonable precautions to maintain health and safety.
Supplier warrants that the prices include sufficient amount for compliance with health and safety laws and regulations.
Supplier must comply with all applicable health and safety laws and ensure subcontractors and employees comply.
Safety requirements are applicable and attached separately.
SHEQ compliance must be demonstrated and legally valid.
Asbestos requirements: OEL 0.2 fibres/ml (4-hour TWA), short-term limit 0.6 fibres/ml (10-minute TWA).
If asbestos identified, risk assessment and control measures; personnel may stop work if area unsafe.
Removal and disposal of asbestos by registered contractor at Purchaser's expense.
Environmental
Source: NEC The provision of manufacturing and supply of various Circuit Breakers.pdfSupplier must comply with all applicable environmental laws and regulations and ensure subcontractors and employees comply.
Environmental requirements are applicable and attached separately.
Environmental compliance requirements may increase operating costs.
Extreme weather events may disrupt manufacturing, logistics, and supply chains.
Contractual Terms
Source: NEC The provision of manufacturing and supply of various Circuit Breakers.pdfContract type: NEC3 Supply Contract (SC3) with options X1 (price adjustment), X2 (changes in law), X4 (parent company guarantee), X7 (delay damages), X13 (performance bond), and Z clauses.
Contract period: 60 months.
Starting date: To be inserted at contract award.
Delivery date: To be indicated on each purchase order.
First programme: Submit within 4 weeks of contract date.
Revised programmes: At intervals no longer than 2 weeks.
Defects date: 52 weeks after delivery.
Defect correction period: 4 weeks (6 weeks for imported products; 3 weeks for programming).
Defect access period: 7 days.
Assessment interval: Upon delivery of each batch.
Payment terms: 30 days for contracts below R50 million; 60 days for contracts above R50 million.
Interest rate: Prime rate of Standard Bank.
Supplier's liability for indirect loss: limited to R0.00.
Supplier's liability for property damage: limited to R25 million (Generation), R7.5 million (Transmission), R2 million (Distribution).
End of liability date: 10 years after delivery.
Adjudicator: Selected from ICE-SA panel; arbitration in Midrand under Association of Arbitrators rules.
Additional Z clauses: cession, joint ventures, B-BBEE status changes, confidentiality, health and safety, tax invoice, ethics, insurance, nuclear liability, asbestos.
Section
Source: NEC The provision of manufacturing and supply of various Circuit Breakers.pdfSHEQ requirements are not evaluation criteria but must be fully met after evaluation and ranking.
Bidders are allowed one resubmission within 7 working days after first evaluation for unmet requirements.
Failure to meet contractual requirements may render the bid non-responsive.
Quality requirements include checks on goods; poor quality checks are a risk.
Submission Guidelines
Source: SAFETY Tender Evaluation Criteria.pdf (unknown)Returnable OHS documents (all must be completed and submitted with the bid):
Evaluation Criteria
Source: SAFETY Tender Evaluation Criteria.pdf (unknown)OHS submission is assessed as Recommended or Not Recommended.
Technical Specifications
Source: SAFETY Tender Evaluation Criteria.pdf (unknown)Scope: supply and delivery of circuit breakers to the Gauteng cluster, on an as-and-when-required basis, over 60 months.
Methodology
Source: SAFETY Tender Evaluation Criteria.pdfThe Baseline OHS Risk Assessment must set out the methodology used to identify, assess and manage OHS risks for the scope of work.
Compliance Requirements
Source: SAFETY Tender Evaluation Criteria.pdf (unknown)OHS compliance (mandatory returnables):
Health & Safety
Source: SAFETY Tender Evaluation Criteria.pdfOHS returnables:
Description
Source: Cuicut Breakers Thresholdsbd6.2 Annah .docSupply and delivery of circuit breakers to the Gauteng cluster on an as-and-when-required basis for a 60-month period. Circuit breakers are a designated switchgear product and must meet a 100% local content threshold measured under SATS 1286.
Submission Guidelines
Source: Cuicut Breakers Thresholdsbd6.2 Annah .doc (unknown)Returnable document
Signatory
Supporting evidence
Disqualification risks
Evaluation Criteria
Source: Cuicut Breakers Thresholdsbd6.2 Annah .doc (unknown)Local production and content threshold
Calculation
Verification
Technical Specifications
Source: Cuicut Breakers Thresholdsbd6.2 Annah .doc (unknown)Scope
Local content standard
Compliance Requirements
Source: Cuicut Breakers Thresholdsbd6.2 Annah .doc (unknown)Local content
Returnable form
Description
Source: Circuit Breaker SDL&I Undewrtaking Annah.docxSupply and delivery of circuit breakers in the Gauteng Cluster on an as and when required basis for 60 months.
Suppliers must contribute to six SDL&I elements throughout the contract: B-BBEE, Localisation, Industrialisation, Skills Development, Job Creation and Supplier Development.
Local content: 100% for Circuit Breakers (Switchgear designation).
No industrialisation requirement as all resources are sourced within South Africa.
Submission Guidelines
Source: Circuit Breaker SDL&I Undewrtaking Annah.docx (unknown)Returnable documents:
Submission method and address are not stated in the available text.
Evaluation Criteria
Source: Circuit Breaker SDL&I Undewrtaking Annah.docx (unknown)Preference point system: 90/10.
B-BBEE scoring:
Specific goals (section 2(1)(d-f) of PPPFA):
Mandatory subcontracting:
Local content:
Technical Specifications
Source: Circuit Breaker SDL&I Undewrtaking Annah.docx (unknown)Scope: supply and delivery of circuit breakers in the Gauteng Cluster on an as and when required basis for 60 months.
Local content: 100% for Circuit Breakers (Switchgear designation).
SDL&I obligations (six elements): B-BBEE, Localisation, Industrialisation, Skills Development, Job Creation and Supplier Development.
Skills development:
Job creation:
Supplier development:
Reporting:
Penalty:
Financial Requirements
Source: Circuit Breaker SDL&I Undewrtaking Annah.docx (unknown)Budget value: not stated.
Contract duration: 60 months.
Subcontracting threshold: mandatory subcontracting of at least 30% of contract value on contracts above R30 million.
Subcontracting cap: no more than 25% of contract value to any entity without equal or higher B-BBEE level, unless an EME with capability.
Penalty: 2% at end of contract for non-compliance with SDL&I obligations.
Bid security, guarantees, retention and payment terms are not stated in the available text.
Compliance Requirements
Source: Circuit Breaker SDL&I Undewrtaking Annah.docx (unknown)CSD registration: required for bidder and subcontractors (CSD report).
Tax compliance: not stated.
B-bbee:
Local content:
Subcontracting:
Sdl&i:
CIDB: not applicable (supply and delivery).
Professional registrations: not stated.
Submission Guidelines
Source: E-Tenderers E-Tendering Training Acknowledgement Form - 27 January 2025 (1).docx (unknown)Mandatory returnable: E-Tenderers' E-Tendering Training Acknowledgement Form (Template ID 240-9722574, Rev 1).
Evaluation Criteria
Source: E-Tenderers E-Tendering Training Acknowledgement Form - 27 January 2025 (1).docx (unknown)Bidders must be able to operate Eskom's e-Tendering solution.
Compliance Requirements
Source: E-Tenderers E-Tendering Training Acknowledgement Form - 27 January 2025 (1).docx (unknown)Mandatory returnable: E-Tenderers' E-Tendering Training Acknowledgement Form (Template ID 240-9722574, Rev 1).
Description
Source: Environmental Specifications_Delivery of Circuit Breakers_FY2627.pdfThe contract covers the manufacture, supply and delivery of circuit breakers to the Gauteng Cluster, drawn down as and when required over a 60-month period.
Evaluation Criteria
Source: Environmental Specifications_Delivery of Circuit Breakers_FY2627.pdf (unknown)Environmental Management Policy assessment
Technical Specifications
Source: Environmental Specifications_Delivery of Circuit Breakers_FY2627.pdf (unknown)Scope
Environmental submission
Compliance Requirements
Source: Environmental Specifications_Delivery of Circuit Breakers_FY2627.pdf (unknown)Environmental management policy
Environmental
Source: Environmental Specifications_Delivery of Circuit Breakers_FY2627.pdfEnvironmental Management Policy
Section
Source: Environmental Specifications_Delivery of Circuit Breakers_FY2627.pdfThe environmental management policy is the sole criterion in this schedule, weighted at 100%.
Description
Source: QUALITY REQUIREMENTS 240-12248652 (Rev 7)_List of Tender Returnables Cat 2.pdfSupply and delivery of circuit breakers to the Gauteng cluster on an as-and-when-required basis for a period of 60 months.
Important Dates
Source: QUALITY REQUIREMENTS 240-12248652 (Rev 7)_List of Tender Returnables Cat 2.pdf (TENDER)Closing date: 15 December 2026 at 10:00 (as per tender record).
No briefing or site visit is mentioned in this quality requirements extract.
Submission Guidelines
Source: QUALITY REQUIREMENTS 240-12248652 (Rev 7)_List of Tender Returnables Cat 2.pdf (TENDER)Returnable documents — all must be completed, signed and submitted with the bid:
Submission method and address: as specified in the main bid document (not detailed in this quality requirements extract).
Closing time: 10:00 on 15 December 2026 (as per the tender record).
Evaluation Criteria
Source: QUALITY REQUIREMENTS 240-12248652 (Rev 7)_List of Tender Returnables Cat 2.pdf (TENDER)Quality evaluation is scored out of a maximum of 15 points across five sections. Bidders must achieve a minimum score of 1 in each section to be considered compliant.
Section A: Quality Management System (maximum 7 points)
Section B: Evidence of QMS in operation (maximum 4 points)
Section C: Draft contract quality plan (1 point)
Section D: Quality control plan (1 point)
Section E: Additional requirements (2 points)
Bidders must submit all required evidence; missing items score zero for that item.
Technical Specifications
Source: QUALITY REQUIREMENTS 240-12248652 (Rev 7)_List of Tender Returnables Cat 2.pdf (TENDER)Supply and delivery of circuit breakers to the Gauteng cluster on an as-and-when-required basis for a period of 60 months.
Quality requirements:
Compliance Requirements
Source: QUALITY REQUIREMENTS 240-12248652 (Rev 7)_List of Tender Returnables Cat 2.pdf (TENDER)Mandatory compliance:
No B-BBEE, CSD, tax clearance, or CIDB requirements are specified in this quality requirements extract.
Section
Source: QUALITY REQUIREMENTS 240-12248652 (Rev 7)_List of Tender Returnables Cat 2.pdfQuality evaluation is scored out of a maximum of 15 points across five sections. Bidders must achieve a minimum score of 1 in each section to be considered compliant.
Section A: Quality Management System (maximum 7 points)
Section B: Evidence of QMS in operation (maximum 4 points)
Section C: Draft contract quality plan (1 point)
Section D: Quality control plan (1 point)
Section E: Additional requirements (2 points)
Bidders must submit all required evidence; missing items score zero for that item.
Description
Source: SAFETY Annexure B.pdfThe main supplier must notify Eskom before appointing any contractor or supplier and before that contractor or supplier starts work.
Submission Guidelines
Source: SAFETY Annexure B.pdf (unknown)Returnable document
Submission method and address are not stated in this annexure; refer to the main bid document for the submission channel and closing time.
Technical Specifications
Source: SAFETY Annexure B.pdf (unknown)Scope
Contractor and supplier management obligations
Quality Management
Source: SAFETY Annexure B.pdfContractor and supplier selection
Oversight and verification
Acknowledgement
Compliance Requirements
Source: SAFETY Annexure B.pdf (unknown)Legislation and standards
Induction
Penalties
Returnable form
Health & Safety
Source: SAFETY Annexure B.pdfApplicable requirements
Post-award obligation
Induction
Penalties
Description
Source: Eskom General Conditions of Purchase - 31 May 2024.pdfThe supplier supplies the goods or executes the works or services set out in the agreement, which comprises the order documents, these general conditions, the specifications, schedules and Eskom-approved drawings.
Technical Specifications
Source: Eskom General Conditions of Purchase - 31 May 2024.pdf (unknown)Scope of supply
Delivery
Acceptance and inspection
Risk and ownership
Quality Management
Source: Eskom General Conditions of Purchase - 31 May 2024.pdfInspection and testing
Rejection
Pricing Schedule
Source: Eskom General Conditions of Purchase - 31 May 2024.pdfPrices and rates
Financial Requirements
Source: Eskom General Conditions of Purchase - 31 May 2024.pdf (unknown)Pricing
Payment terms
Supplier forms
Penalties
Compliance Requirements
Source: Eskom General Conditions of Purchase - 31 May 2024.pdf (unknown)Statutory compliance
Ethics
Supplier form
Contractual Terms
Source: Eskom General Conditions of Purchase - 31 May 2024.pdfContract basis
Indemnity
Warranty
Assignment and subcontracting
Breach and termination
Governing law
Ethics
Sets the constitutional standard for fair, equitable, transparent, competitive and cost-effective public procurement.
Relevant because this is a South African public-sector procurement opportunity.
Act 5 of 2000
Covers preferential procurement and preference-point systems used in public tenders.
Relevant because this is a South African public-sector procurement opportunity.
Act 12 of 2004
Supports anti-corruption controls and supplier integrity in procurement processes.
Relevant because this is a South African public-sector procurement opportunity.
Act 28 of 2024
Provides the national framework for public procurement across government.
Relevant because this is a South African public-sector procurement opportunity.
Act 2 of 2000
Supports access to tender records, award decisions and public-sector procurement information.
Relevant because this is a South African public-sector procurement opportunity.
Act 3 of 2000
Supports lawful, reasonable and procedurally fair administrative tender decisions.
Relevant because this is a South African public-sector procurement opportunity.
These rules are linked to the work category, industry, or regulated service area.
Act 38 of 2000
Important for public-sector construction and infrastructure tenders that require contractor grading or construction procurement standards.
Relevant because this tender appears to involve engineering, technical design, maintenance, or regulated built-environment work.
Act 85 of 1993
Sets health and safety duties for contractors, employers and service providers working on public-sector sites.
Relevant because this tender appears to involve engineering, technical design, maintenance, or regulated built-environment work.
Act 46 of 2000
Relevant where professional engineering services or regulated engineering work may be required.
Relevant because this tender appears to involve engineering, technical design, maintenance, or regulated built-environment work.
Address
GAUTENG - GAUTENG - GAUTENG - 1682
Source confidence
High source confidence
Official source
eTenders.gov.za
Documents found
25
Last checked
24 Nov 2026
AI status
Enhanced
Data conflicts
None detected
This tender has strong source evidence, including source metadata and supporting tender information synced from the government tender portal.
Tenders SA is not the issuing authority. All tenders are automatically synced from the official government tender portal. Always confirm final submission details, closing dates, briefing sessions, eligibility requirements, and documents on the official government portal before applying.
Key Personnel
Provinces Active
Industries
Median Estimate
R 1 743 960
Range
Based on 25 comparable awarded tenders. Companies with similar profiles typically bid near the median.
* Estimates are based on historical data and do not guarantee actual award values.
Get deep intelligence on Supplies: Electrical Equipment. Unlock full pricing strategies, bid frequency, and historical win rates.
Learn how to submit a winning bid with these related articles
💡 Want more tendering tips and strategies?
Explore Our Blog