Grootvlei Power Station, between Heidelberg and Villiers next to N3 - Grootvlei - Balfour - 2420
Organization Type
GOVERNMENT
Published
30 Sept 2026
OCDS Reference
ocds-9t57fa-172287
Summary
ESKOM requires the supply, delivery and service/repair/refurbishment of ge SA plus lv switchgear assemblies/components installed at grootvlei power station, on an as-and-when-required basis for 60 months. Bidders must comply with eskom's OHS legal and other requirements, including the OHS act and ESKOM standards, and must acknowledge and sign the OHS acknowledgement form. The most consequential consideration is the mandatory OHS compliance and the ability to manage contractors and suppliers in line with eskom's requirements.
Key Requirements
Closing date: 30 November 2026 at 10:00 (submission method and address not stated in the document; confirm with Eskom).
Mandatory OHS acknowledgement: Bidders must sign the Acknowledgement Form for Eskom OHS legal and other requirements (Annexure B) and confirm understanding of the OHS requirements and consequences of non-compliance.
OHS compliance: Bidders must comply with Eskom OHS standards (e.g., Eskom standard 32-136), the OHS Act, and the Compensation for Occupational Diseases and Illnesses Act; after award, align company processes to Eskom OHS requirements.
Contractor management: Bidders must demonstrate the process and selection criteria for appointing contractors/suppliers, notify Eskom prior to appointment, and ensure contractors have adequate resources and competencies; the main supplier is accountable for contractor compliance and must monitor via audits and assessments.
Penalties and termination: Penalties apply for non-conformance with Eskom/statutory OHS requirements; grounds for termination of contractor work must be provided by the main supplier; non-conformances are dealt with directly with the main supplier.
Returnable documents: All required forms and documents must be completed, signed, and submitted with the bid; failure to provide accurate and complete information may lead to disqualification.
Evaluation: Evaluation will consider compliance with Eskom OHS requirements, bidder's ability to manage contractors and suppliers, and adequacy of resources and competencies; bidders must demonstrate a clear process for contractor appointment.
Supply, Delivery and Service/Repair/Refurbishment of GE SA Plus LV
Switchgear Assemblies/Components installed at Grootvlei Power Station. As and
when required, for a period of 60 Months
Tender context
Return to this tender’s issuing organisation, province, or category.
Supply, delivery and service/repair/refurbishment of ge SA plus lv switchgear assemblies/components installed at grootvlei power station. As and when required, for a period of 60 months
Document read. The full tender notice and its supporting documents are read end-to-end. Key sections, requirements, dates, and contact details are identified and pulled into a working summary you can act on.
Compliance review. The working summary is checked against South African procurement standards — PFMA, PPPFA, B-BBEE, CIDB, local content, and preferential procurement — so nothing critical is missed before you start your bid response.
DocumentSafety Requirements.pdfReview complete
Submission Guidelines
Source: Safety Requirements.pdf (unknown)
Returnable documents must be completed, signed, and submitted with the bid. The bidder must sign a declaration confirming that they have obtained and understood the referenced safety documents and the consequences of non-compliance. The submission must include all required forms and documents as specified in the tender. The bidder must ensure that all information is accurate and complete; failure to do so may lead to disqualification.
Important Dates
30 Sept
2026
PUBLICATION
Tender Published
Tender was published
24 Feb
2027
DEADLINE
Closing Date
Tender closing date
Procurement Rules & Compliance ContextThis tender may be governed by South African public procurement rules covering fairness, transparency, preferential procurement, anti-corruption, administrative justice and access to information.
10 rules
These references help suppliers understand the public-procurement framework around this opportunity. They are generated from the tender category, issuing organisation type and procurement context.
Core procurement rules
These rules commonly apply to South African public-sector procurement.
7
Broad-Based Black Economic Empowerment Act (B-BBEE Act)
Act 53 of 2003
high
Provides the empowerment-compliance context often used in public-sector supplier evaluation.
Relevant because this is a South African public-sector procurement opportunity.
Constitution of the Republic of South Africa, 1996 – Section 217
Act 108 of 1996 (s217)
high
This is general procurement context, not legal advice. Always verify requirements in the official tender documents and issuing authority notices.
Eskom requires a contractor for the supply, delivery, and service/repair/refurbishment of GE SA Plus LV switchgear assemblies and components installed at Grootvlei Power Station, on an as-and-when-required basis for 60 months. The contract is a NEC3 Term Service Contract (TSC3) with a priced price list (Option A), including inspection, refurbishment, testing, supply, and retrofit of breakers, relays, and related components.
Supply, delivery and service/repair/refurbishment of GE SA Plus LV switchgear assemblies/components installed at Grootvlei Power Station, as and when required for a period of 60 months. The contractor must comply with Eskom's environmental management system, including waste management procedures and incident reporting.
Supply and delivery of GE SA Plus LV switchgear assemblies and components, including service, repair and refurbishment, at Grootvlei Power Station, on an as-and-when-required basis for 60 months. The contract is issued by Eskom and is subject to a staged quality-management evaluation covering ISO 9001 certification or documented QMS, a contract quality plan, a quality control plan, and user-defined quality deliverables.
Supply and delivery of GE SA Plus low-voltage switchgear assemblies and components, including service, repair and refurbishment, as and when required at Grootvlei Power Station for a period of 60 months.
Supply, delivery and service/repair/refurbishment of GE SA Plus LV switchgear assemblies/components installed at Grootvlei Power Station, as and when required, for a period of 60 months. The contract will be an NEC3 Term Service Contract with Eskom Holdings SOC Ltd.
Supply, delivery and service/repair/refurbishment of GE SA Plus LV switchgear assemblies and components installed at Grootvlei Power Station, on an as-and-when-required basis for 60 months.
Win Eskom tenders with AI Tender Matching, technical document analysis, compliance scoring, and structured bid support for energy and engineering contracts.
Similar Tenders
Matched by category & region
Supplier Readiness Hub
Free guidance to prepare before you bid
Not sure if your business is ready for this tender? Check CSD, CIDB, and B-BBEE requirements, run a readiness assessment, and move from opportunity to submission.
Open, inspect, issue inspection report, refurbish or replace non-return, Globe, Ball, AMOT, Butterfly, Wedge, Gate, Parallel Slide and Diaphragm valves of the boiler and turbine auxiliary systems at Kriel Power Station for a period of five
years
Bid-ready summary. The submission guidelines, evaluation criteria, technical, financial, and compliance sections are refined into professional, easy-to-scan prose. This is the final version you can rely on when preparing your bid or briefing your team.
We refine every tender document through these stages so you can brief your team and prepare your bid with confidence. Anything marked as "in progress" will be upgraded automatically — no action required from you.
Document read
Compliance review
Bid-ready summary
Evaluation Criteria
Source: Safety Requirements.pdf (unknown)
The evaluation will consider compliance with Eskom's OHS requirements, the bidder's ability to manage contractors and suppliers, and the adequacy of resources and competencies. The bidder must demonstrate a clear process and selection criteria for appointing contractors. Non-compliance with OHS requirements may result in penalties. The bidder must also comply with all applicable legal and Eskom requirements during contract execution.
DocumentQuality Requirements .pdfReview complete
Description
Source: Quality Requirements .pdf
The contract covers GE SA Plus LV switchgear assemblies and components installed at Grootvlei Power Station, over a five-year period.
Submission Guidelines
Source: Quality Requirements .pdf (TENDER)
Returnable documents for the quality evaluation
Form A: completed and signed.
Section A evidence: either a valid ISO 9001 certificate (Option 1) or documented QMS evidence (Option 2).
Section B evidence: documented proof that the QMS is in operation.
Section C: a draft contract quality plan specific to the scope of work (ISO 10005).
Section D: a draft or example inspection and test plan (ITP) or quality control plan (QCP) drawn from similar or previous work (ISO 10005).
Section E: manufacture test procedures and product test results (manuals, data sheets or books).
Evaluation Criteria
Source: Quality Requirements .pdf (TENDER)
Quality requirements are scored per deliverable, with each indicator worth 1 point.
Section A — Quality management system (one option applies)
Option 1 (ISO 9001 certification): 4 points. A valid certificate from an ISO-accredited body, with the product/service scope defined and relevant, issued by an approved and authorised certification authority holding recognised international accreditation, and still within its expiry date.
Option 2 (documented QMS, uncertified): 7 points. A QMS manual or scope-defining document/quality method statement, a top-management-approved quality policy and quality objectives, and documented information for document and record control (clause 7.5), control of nonconforming outputs (clause 8.7), nonconformity and corrective action (clause 10.2), and internal audit (clause 9.2).
Section B — Evidence of QMS in operation: 5 points
Organisation chart and responsibility matrix covering defined roles, responsibilities and authorities, including the quality management function (clause 5.3).
Documented control of externally provided processes, products and services, including criteria for evaluation, selection, performance monitoring and re-evaluation of external providers (clause 8.4).
Proof that all materials and equipment comply with Eskom and other national/international standards: valid calibration/test certificates for all equipment, plus an asset/tool register with maintenance plans and records.
Documented preservation of goods: identification, handling, contamination control, packaging, storage, transportation and protection.
Project risk and opportunity register with an action plan or template. An OHS risk assessment is not acceptable for this item.
Section C — Contract quality plan: 1 point
A draft contract/project quality plan specific to the scope of work (ISO 10005), covering the QA deliverables.
Section D — Quality control plan: 1 point
A draft or example ITP or QCP aligned to the scope of work (ISO 10005), based on similar or previous work.
Section E — Additional requirements: 2 points
Form A completed and signed.
Manufacture test procedures and product test results (manuals and data sheets/books).
Technical Specifications
Source: Quality Requirements .pdf (TENDER)
Scope
Supply, delivery and service/repair/refurbishment of GE SA Plus LV switchgear assemblies and components installed at Grootvlei Power Station.
Work is performed as and when required over a 60-month (5-year) period.
Quality deliverables
QMS meeting ISO 9001, evidenced by certification or documented compliance.
Contract quality plan and quality control plan / ITP aligned to the scope of work.
Calibration and test certificates for equipment, plus an asset/tool register with maintenance plans and records.
Preservation of goods controls covering identification, handling, contamination, packaging, storage, transport and protection.
Project risk and opportunity register with action plan.
Manufacture test procedures and product test results.
Compliance Requirements
Source: Quality Requirements .pdf (TENDER)
Quality management
ISO 9001 certification from an accredited body, or documented QMS compliance with the listed ISO 9001 clauses.
The certification authority must be approved, authorised and hold recognised international accreditation; the certificate must be valid and its scope relevant to the product or service.
Documentation
Form A completed and signed.
Valid calibration/test certificates for all equipment.
Asset/tool register with maintenance plans and records.
Proof that materials and equipment comply with Eskom and national/international standards.
Section
Source: Quality Requirements .pdf
Quality deliverables are scored individually, each indicator worth 1 point.
Section A — Quality management system (one option applies)
Option 1 (ISO 9001 certification): 4 points. Valid certificate from an ISO-accredited body, with a defined and relevant scope, issued by an approved and authorised authority with recognised international accreditation, and within its expiry date.
Option 2 (documented QMS, uncertified): 7 points. QMS manual or scope-defining document/quality method statement, top-management-approved quality policy and quality objectives, and documented information for document and record control (clause 7.5), control of nonconforming outputs (clause 8.7), nonconformity and corrective action (clause 10.2), and internal audit (clause 9.2).
Section B — Evidence of QMS in operation: 5 points
Organisation chart and responsibility matrix covering roles, responsibilities and authorities, including the quality management function (clause 5.3).
Documented control of externally provided processes, products and services, with criteria for evaluation, selection, performance monitoring and re-evaluation of external providers (clause 8.4).
Proof of compliance of all materials and equipment with Eskom and national/international standards: valid calibration/test certificates and an asset/tool register with maintenance plans and records.
Documented preservation of goods.
Project risk and opportunity register with action plan or template; an OHS risk assessment is not acceptable.
Section C — Contract quality plan: 1 point. Draft contract/project quality plan specific to the scope of work (ISO 10005), covering the QA deliverables.
Section D — Quality control plan: 1 point. Draft or example ITP or QCP aligned to the scope of work (ISO 10005), based on similar or previous work.
Section E — Additional requirements: 2 points. Form A completed and signed, plus manufacture test procedures and product test results (manuals and data sheets/books).
DocumentGE SA PLUS Bill of quantities.xlsxReview complete
Description
Source: GE SA PLUS Bill of quantities.xlsx
The requirement covers the supply, delivery, servicing, repair and refurbishment of GE SA Plus low-voltage switchgear assemblies and components installed at Grootvlei Power Station, on an as-and-when-required basis over 60 months.
The bill of quantities lists individual components rather than complete assemblies. Items span cartridge fuses, fuse holders and bases, circuit breakers, fused isolators and switches, protection and control relays, indicating lights, and panel-mounted electrical meters. Descriptions give full electrical and mechanical characteristics — current and voltage ratings, connection type, dimensions, case material, interrupting capacity, applicable standards and supplier or manufacturer part numbers.
Technical Specifications
Source: GE SA PLUS Bill of quantities.xlsx (unknown)
Scope
Supply, delivery, servicing, repair and refurbishment of GE SA Plus low-voltage switchgear assemblies and components installed at Grootvlei Power Station.
Work is called off as and when required over a 60-month period.
Pricing basis
Bidders price against a bill of quantities spreadsheet. Each line carries a material number, material type, material group, base unit of measure and a full technical description.
Unit of measure for every listed line is EA (each).
Item categories in the bill of quantities
Material group 08008000 — cartridge fuses: current-limiting, HRC, diazed, bottle, blade and ferrule types; ratings from 0.063 A up to 1.25 kA; voltages from 100 V to 10/12 kV; ceramic and glass bodies; specifications include BS 88, BS 88-1967, BS 2692-1 and IEC 60269; utilisation category GG; several lines marked for LV switchgear.
Material group 07007000 — fuse holders and bases: panel, inline, clip-in, blade, screw-clamp and front/back-connected mountings; ratings up to 630 A and 660 VAC.
Material group 07003000 — circuit breakers and switches: miniature, thermal-magnetic, hydraulic-magnetic, moulded-case and air circuit breakers; fused isolators; selector, pressure, toggle, push-button and disconnect switches; ratings up to 1.6 kA and 600 VAC.
Material group 01013000 — relays: overload, control, voltage, phase-failure, generator, differential protection, earth fault, auxiliary and trip relays; coil voltages include 220 VDC and 380 VAC.
Material group 09001003 — indicating lights: pilot, neon and miniature incandescent types, 48 V to 250 V, various colours.
Material group 07003001 — electrical meters: analogue and digital voltmeters and ammeters, flush panel mount.
Material groups 01017004 and 01017007 — miniature circuit breakers and disconnect/fused isolator switches.
Named equipment references
OEM and product references appearing in the descriptions include GE Steam Power Service, ABB, MEM / Memrex-Exel, Reyrolle, GEC, Crouse Hinds, Allen Bradley, Delle Alsthom, Hawker Siddeley Vanossi, Schneider G60 series and Micom P343 / P632 / P633 protection relays.
At least one line specifies that only the MEM brand is acceptable for that item.
Appendix A — Unit 1 to 6 switchgear boards, listed by drawing number and KKS code, including the Grootvlei MV and LV electric diagram (0.19/16254) and boards such as 10BFA Unit 1 Turbine Board, 10BFB Unit 1 Turbine Essential Board, 10BFG Unit 1 Boiler Board, 10BFD Unit 1 Boiler Essential, 11BFH and 12BFH Unit 1 FFP Boards, 10BFC Unit 1 CW Unit Board, 10BFE Unit 1 Equipment Room Battery Room HVAC Board, 10BLA/10BLB/10BLC Unit 1 lighting boards, with equivalent turbine, boiler, FFP, CW, HVAC and lighting boards for Units 2 to 6.
Appendix B — Common plant switchgear boards, including station boards 01BJA to 04BJA, 01BHE and 02BHE turbine standby boards, 01BJF to 03BJF water treatment plant boards, 01BJC to 04BJC conveyor boards, 01BJE and 02BJE coal plant boards, HP and LP fuel oil light-up boards, workshop boards, distribution and sub-distribution boards, CW reserve board, MCC bypass conveyor board, Balfour pump board, effluent plant board, RO plant board, ash water return board, Terrence polluted water dam east board, terminal reservoir board, Nimrod tower board, plater shop board, by-pass sediment plant board, common essential lighting board, highlift and intake pumphouse boards, and clarification plant board.
Supply, delivery, service, repair and refurbishment of GE SA Plus LV switchgear assemblies and components installed at Grootvlei Power Station, called off as and when required over 60 months (5 years) from signature of the contract.
Installed switchgear is floor-mounted, metal-clad modular design, with circuits grouped in metal-enclosed compartments (tiers), commissioned between 01/2008 and 01/2011.
Original equipment manufacturer was General Electric; ABB acquired GE Industrial Solutions in 2018, so no GE service, technical or spares support remains.
The scope forms the input to the NEC Part 3 / Part C3 Scope of Work.
Plant design life runs to the end of Grootvlei Power Station life in 2027.
Plant codification uses the KKS numbering system.
Supply
New, original or approved-equivalent GE SA Plus LV switchgear assemblies and components: circuit breakers (ACBs, MCCBs), busbars and busbar supports, relays, control modules, metering devices, protection and interlocking systems, auxiliary and control accessories.
Components must meet the original equipment specification and integrate into the existing systems.
Delivery to Grootvlei Power Station, with equipment data sheets and certificates of conformance.
Service, repair and refurbishment
On-site inspection and condition assessment of installed switchgear.
Repair or refurbishment of defective units: replacement of worn parts, re-insulation or busbar repair, calibration of instrumentation, relay reset and configuration.
Mechanical servicing to OEM standards.
Testing and commissioning to confirm operational readiness.
Updated circuit diagrams, layout drawings and configuration settings where applicable.
Emergency response
24/7 emergency contact and response coordination line.
Emergency calls acknowledged within 1 hour of notification.
Qualified technician or team mobilised to site within 24 hours, depending on the emergency.
Temporary solutions provided until permanent repair or replacement is complete.
Readily available stock of critical spares; expedited procurement, transport and delivery of non-stocked emergency components.
On-site diagnostics, temporary isolation and fault clearance; on-site repair or removal of faulty equipment for off-site refurbishment.
Functional testing and safe restoration of affected switchgear.
Breaker inspection (strip and assess, assessment report, quote): 100.
Breaker transportation (collect from Grootvlei to contractor workshop and return after repair): 36.
Breaker refurbishment per assessment report: 50.
Breaker testing and commissioning at the contractor workshop, with signed test certificates and check sheets: 50. Checks cover mechanism open/close operation, racking in and out, interlock verification, speed checks, voltage pickup on trip and close coils, trip range, main contact resistance and pressure test.
Supply of ACB breaker and components: 100.
Retrofit of equivalent ACB, with new commissioning drawings and site acceptance testing: 10.
Replacement or supply of breaker shutters and spouts: 15.
Protection relay inspection, assessment and testing: 30.
Relay transportation: 15.
Relay refurbishment per assessment report: 15.
Relay configuration and commissioning: 15.
Relay retrofit with new drawings and site acceptance testing: 10.
Panel door repair with report and warranty: 15; panel door replacement: 15.
Inspection glass replacement: 15.
Fuse and contactor replacement: 15.
LV switchgear training for 40 people.
Stock and guarantees
The contractor holds stock of critical GE SA Plus LV switchgear spares at Grootvlei Power Station; Eskom holds stock of assemblies and components under its current strategy.
Site Acceptance Tests and Factory Acceptance Tests are performed on critical spares.
Documentation to be supplied
Type test result certificates, medical and induction certificates, safety file, quality control process files, installation and commissioning manuals.
Site access
Compliance with site safety, security and environmental regulations; site induction where required; safety file.
Drawings
Appendix A lists Unit 1–6 switchgear boards by drawing number and KKS code (for example 10BFA Unit 1 Turbine Board, 10BFG Unit 1 Boiler Board, 10BLA/10BLB/10BLC Unit 1 lighting boards, and equivalents for Units 2 to 6).
Appendix B lists common plant boards (station boards 01BJA–04BJA, turbine standby boards, water treatment, conveyor, coal plant, fuel oil light-up, workshop, distribution and sub-distribution, CW reserve, MCC bypass conveyor, Balfour pump, effluent, RO plant, ash water return, Terrence polluted water dam east, terminal reservoir, Nimrod tower, plater shop, by-pass sediment plant, common essential lighting, highlift and intake pumphouses, clarification plant).
All material and equipment must be new and of the specified standard and quality.
Design and manufacture of equipment, and the complete installation, must be carried out and tested to the latest issue or amendment of the applicable standards and regulations.
Eskom standards: 240-28463367 SHE Organization; 240-30008949 Safety, Health and Environmental Specifications for Contractors; 240-49230111 HAZOP Guideline; 240-55944466 Supplier Contract Quality Requirements Specification; 240-114967625 Operating Regulations for High Voltage Systems; 240-150642762 and 36-681 Generation Plant Safety Regulations; 32-421 Cardinal Rules; OPS 0158 AKZ Power Plant Classification System; QM 58 Supplier Contract Quality Requirements; 240-56535985 Operations Management of MV Switchgear; 240-56227573 Air-Insulated Withdrawable AC Metal-Enclosed Switchgear and Controlgear above 1 kV up to 52 kV; 240-56357424 MV & LV Switchgear Protection Standard; 240-56227516 LV Switchgear Controlgear Assembly for 1000 V AC and 1500 V; 2030 LV Switchgear and Controlgear Assembly – Preventative Maintenance Tasks; GVLEG 0074 Switchgear Maintenance Execution Strategy.
General standards: SANS 62271 High-Voltage Switchgear & Controlgear (Parts 1, 100, 102 and 200); 7.1/ST/02 Quality Requirements for Engineering and Construction Work; ISO 9001 Quality Management Systems; OSH Act; SANS 10142 Code of Practice for the Wiring of Premises.
Appendix C schedule of GE Plus LV switchgear spares and consumables installed at Grootvlei Power Station, listed by item number, material number, description and quantity per year.
Cartridge fuses across a wide range of ratings, for example 16 A/415 V, 32 A/415 V, 20 A/500 V, 10 A/500 V, 6 A/415 V, 63 A/550 V, 400 A/550 V, 200 A/550 V and 100 A/10-12 kV.
Fuse holders, for example 30 A, 15 A, 20 A, 400 A, 600 A, 63 A, 100 A, 200 A and 630 A.
Indicating lights (pilot and neon), covers, enclosed links, miniature circuit breakers of various ratings and poles, disconnect switches and isolators, selector switches, pushbuttons, pressure switches, toggle switches, overload relays with various trip ranges, control, voltage and phase-failure relays, contactors, auxiliary contacts, electrical meters (voltmeters and ammeters), transducers, and generator, differential, earth-fault and trip relays.
Annual quantities across the listed items range from 20 to 500.
Priced against the Appendix C schedule of GE Plus LV switchgear spares and consumables, which lists each item by item number, material number, description and quantity per year; annual quantities across the listed items range from 20 to 500.
Work is called off as and when required over the 60-month contract term.
Guarantees and testing
The contractor must guarantee the supplied LV switchgear assemblies and components at Grootvlei Power Station.
Site Acceptance Tests and Factory Acceptance Tests are carried out on critical spares.
Stock obligation
The contractor must hold stock of critical GE SA Plus LV switchgear spares at Grootvlei Power Station for the duration of the contract.
All material and equipment must be new and of the specified standard and quality.
Design, manufacture, complete installation and testing must follow the latest issue or amendment of the applicable Eskom and national standards, including:
240-28463367 SHE Organization; 240-30008949 SHE Specifications for Contractors; 240-49230111 HAZOP Guideline; 240-55944466 Supplier Contract Quality Requirements Specification; QM 58 Supplier Contract Quality Requirements.
240-114967625 Operating Regulations for High Voltage Systems; 240-150642762 and 36-681 Generation Plant Safety Regulations; 32-421 Cardinal Rules.
240-56535985 Operations Management of MV Switchgear; 240-56227573 Air-Insulated Withdrawable AC Metal-Enclosed Switchgear and Controlgear above 1 kV up to 52 kV; 240-56357424 MV & LV Switchgear Protection Standard; SANS 62271 High-Voltage Switchgear & Controlgear (Parts 1, 100, 102 and 200).
240-56227516 LV Switchgear Controlgear Assembly for 1000 V AC and 1500 V; 2030 LV Switchgear and Controlgear Assembly – Preventative Maintenance Tasks; GVLEG 0074 Switchgear Maintenance Execution Strategy.
7.1/ST/02 Quality Requirements for Engineering and Construction Work; ISO 9001 and ISO 9000 Quality Management Systems; OSH Act; SANS 10142 Code of Practice for the Wiring of Premises.
OPS 0158 AKZ Power Plant Classification System applies to plant codification.
Certification
A Certificate of Compliance must be issued where refurbishment involves replacement of busbars, circuit breakers or switch disconnectors; changes to control wiring, protection or metering circuits; re-termination of cables or conductors; modifications to earthing or bonding; or any change affecting electrical safety or SANS 10142-1 compliance. The CoC certifies the refurbished switchgear meets SANS 10142-1 and is safe to energise.
Quality control
Quality control plans apply to incoming product and services; all materials are signed off by the system engineer, with hold and witness points marked.
Site compliance
Compliance with all site safety, security and environmental regulations; site induction where required; safety file.
Documentation
Type test result certificates, medical and induction certificates, safety file, quality control process files, installation and commissioning manuals.
The contract covers the supply, delivery, servicing, repair and refurbishment of GE SA Plus LV switchgear assemblies and components installed at Grootvlei Power Station, executed as and when required over 60 months.
Technical Specifications
Source: Eniviromental Requirements .pdf (unknown)
Scope of work
Supply, delivery, servicing, repair and refurbishment of GE SA Plus LV switchgear assemblies and components installed at Grootvlei Power Station.
Work is called off as and when required over a contract period of 60 months.
Deliveries are made to Grootvlei Power Station, Mpumalanga.
Delivery conduct on site
Delivery vehicles must be inspected for leaks before entering site; leaking vehicles are not permitted.
Any environmental incident during delivery must be reported to the employer within 24 hours of it occurring or of the contractor becoming aware of it.
Quality Management
Source: Eniviromental Requirements .pdf
Employer personnel carry out regular environmental audits. The contractor must participate in these audits and ensure that the resulting corrective actions are carried out.
Compliance Requirements
Source: Eniviromental Requirements .pdf (unknown)
Environmental legal compliance
The contractor carries the section 28 'Duty of Care' under the National Environmental Management Act and must prevent pollution and environmental degradation.
Compliance is required with the National Environmental Management Act and the National Environmental Management: Waste Act, and with all applicable Eskom procedures.
Supply, delivery and service, repair or refurbishment of GE SA Plus LV switchgear assemblies and components installed at Grootvlei Power Station, on an as-and-required basis under an NEC3 Term Service Contract (TSC3).
Important Dates
Source: NEC - (TSC3) - LV switch gear.pdf (unknown)
Closing: 30 November 2026 at 10:00
Service period: 60 months
First plan due: within 1 week of the Contract Date
Period for reply: 3 working days for normal conditions; 24 hours for emergencies
Task Order programme due: within 14 days of receiving a Task Order
Assessment interval: 1 week after delivery
Payment: 60 days after the assessment date
Price adjustment base date: one month before the tender closing date; prices fixed for the first 12 months
Contact Information
Source: NEC - (TSC3) - LV switch gear.pdf (unknown)
Source: NEC - (TSC3) - LV switch gear.pdf (unknown)
Returnable documents
Form of Offer and Acceptance (C1.1): signed by a duly authorised representative, stating the offered total of the Prices exclusive of VAT, VAT at 15%, and the total inclusive of VAT.
Contract Data Part Two: the Contractor's data, including the direct and subcontracted fee percentages, the key people and the Contractor's plan.
Priced Price List (C2.2): a rate or price for every service and material item.
Schedule of Deviations: the only valid route for any deviation from the tender documents.
The tenderer's CIDB registration number must be entered on the Form of Offer.
Offer and acceptance
The Offer may be accepted by the Employer before the end of the period of validity stated in the Tender Data.
The agreement takes effect when the tenderer receives one fully completed and signed original copy, including the Schedule of Deviations if any.
Within two weeks of receiving the completed agreement, the Contractor must contact the Employer's agent to arrange delivery of securities, bonds, guarantees, proof of insurance and other required documents.
Technical Specifications
Source: NEC - (TSC3) - LV switch gear.pdf (unknown)
Scope
Supply, delivery and service, repair or refurbishment of GE SA Plus LV switchgear assemblies and components installed at Grootvlei Power Station, on an as-and-required basis over 60 months.
Work is instructed by Task Order; the Contractor provides the service in accordance with the Service Information (Part C3).
Price list quantities (services)
Breaker inspection (strip and assess, assessment report and quote): 100
Breaker transportation (collect from and return to Grootvlei): 36
Breaker refurbishment per assessment report: 50
Breaker testing and commissioning at the Contractor's workshop: 50
Supply of ACB breaker and components: 100
Breaker retrofit (supply equivalent ACB, new drawings, test and commission): 10
Functional checks: mechanism open and close, racking in and out
Interlock verification
Speed checks
Voltage pickup on trip and close coils
Breaker trip range
Main contact resistance
Pressure test
Signed test certificates and check sheets must be provided.
Materials
A priced materials list (item numbers and descriptions) forms part of the Price List; many line items carry an expected quantity of 300.
Methodology
Source: NEC - (TSC3) - LV switch gear.pdf (unknown)
Execution approach
Breakers are collected from Grootvlei Power Station, stripped and assessed, refurbished per the assessment report, tested and commissioned at the Contractor's workshop, then returned to Grootvlei.
ACB breakers and components are supplied; retrofits include an equivalent ACB, new drawings and site acceptance testing.
Protection relays are assessed, tested, stripped, refurbished, configured and commissioned; retrofits include an equivalent relay, new drawings and site acceptance testing.
LV switchgear training is provided for employees.
Experience & Qualifications
Source: NEC - (TSC3) - LV switch gear.pdf
Key people
The Contractor must name its key people in Contract Data Part Two, with each person's job, responsibilities, qualifications and experience.
CVs and further key-person data must be provided.
Contractor's data
The Contractor completes Contract Data Part Two, including the direct and subcontracted fee percentages, the risk register matters, the Contractor's plan, and the tendered total of the Prices (exclusive of VAT).
Quality Management
Source: NEC - (TSC3) - LV switch gear.pdf
Quality and SHEQ
Low service damages apply for poor workmanship or quality failure: 1% per month of the Task Order value, limited to 5%; the failure is assessed and confirmed within 4 weeks.
SHEQ non-conformance reports: 1% per month of the Task Order value for 1-2 non-conformances; 5% per month for more than 3 non-conformances.
Breaker and relay testing must produce signed test certificates and check sheets.
Materials are listed with item numbers and expected quantities (many at 300).
Pricing Schedule
Source: NEC - (TSC3) - LV switch gear.pdf
Pricing assumptions (C2.1, Option A)
The Price List is the pricing document; the service is provided in accordance with the Service Information.
Items are priced as lump sums, or as a rate multiplied by an expected quantity, or a mix.
Lump-sum items are not adjusted if the actual quantity differs; only a compensation event changes the Prices.
The Contractor's plan must show how each Price List item relates to the operations on the plan.
The tendered total of the Prices is stated exclusive of VAT.
Financial Requirements
Source: NEC - (TSC3) - LV switch gear.pdf (unknown)
Pricing
NEC3 Option A: a priced contract with a price list. Items are priced as lump sums, or as a rate multiplied by an expected quantity, or a mix.
The tendered total of the Prices is stated exclusive of VAT; VAT is added at 15%.
Lump-sum items are not adjusted if the actual quantity differs; only a compensation event changes the Prices.
Payment
Assessment interval: 1 week after delivery.
Payment is made 60 days after the assessment date.
A tax invoice is submitted within one week of receiving the payment certificate; the Employer's VAT number 4740101508 must appear on each invoice.
Interest on late payment is calculated at the Standard Bank prime rate (365-day year).
Price adjustment (Option X1)
Base date for indices: one month before the tender closing date.
Prices are fixed for the first 12 months of the contract.
Composition: Fixed portion 15%, Final Machined 65%, Transport 5%, Labour 15%.
Liability limits
Contractor's liability for indirect or consequential loss: limited to R0.0.
Contractor's total liability: limited to the total of the Prices, except for the additional excluded matters (design defects, manufacture and fabrication defects, loss or damage to third-party property, death or injury, intellectual property infringement), which are unlimited.
Employer's liability for the Contractor's indirect or consequential loss: limited to R0.00.
Insurance
The Contractor provides the insurances in Insurance Table A from the starting date until completion or termination.
The Employer provides the insurances in Insurance Table B.
Low service damages (Annexure A)
Applied as a percentage of the issued purchase order value when targets are missed.
Delivery date for supply of water pumps: 1% per month of the Task Order value, limited to 5%.
Delivery date for refurbishment of water pumps: 1% per month, limited to 5%.
Poor workmanship or quality failure: 1% per month, limited to 5%.
SHEQ non-conformances: 1% per month for 1-2 non-conformances; 5% per month for more than 3 non-conformances.
Compliance Requirements
Source: NEC - (TSC3) - LV switch gear.pdf (unknown)
Registration and status
A CIDB registration number must be provided on the Form of Offer.
The Contractor must comply with the Construction Regulations 2014 under the Occupational Health and Safety Act, and may be appointed Principal Contractor for the Affected Property.
The Contractor must comply with all applicable environmental laws and the Employer's asbestos standard.
B-bbee
Any change in the Contractor's B-BBEE status must be reported to the Employer within 7 days.
An updated verification certificate and supporting documents must be submitted within 30 days of the notification.
A decrease in B-BBEE status may lead to renegotiation or termination; failure to notify may be grounds for termination.
Ethics (Z11)
No coercive, collusive, corrupt, fraudulent or obstructive action is permitted during procurement or execution.
The Employer may terminate if a prohibited action occurs and the Contractor did not act to prevent or remedy it.
Insurance
The Contractor must provide the insurances in Insurance Table A and certificates from its insurer or broker on request.
Confidentiality
Contract information must not be disclosed to others; images of the Affected Property require the Service Manager's prior written consent.
Health & Safety
Source: NEC - (TSC3) - LV switch gear.pdf
Health, safety and environment (Z6)
The Contractor takes all reasonable precautions to maintain the health and safety of persons during the service.
The Contractor may be appointed Principal Contractor under the Construction Regulations 2014 (Occupational Health and Safety Act) for the Affected Property.
The total of the Prices must include sufficient allowance for compliance with the Construction Regulations and all applicable health and safety laws.
The Contractor must ensure its subcontractors, employees and others under its direction comply.
Asbestos (Z14)
Occupational exposure limit: 0.2 fibres/ml over a 4-hour TWA; short-term limit 0.6 fibres/ml over a 10-minute TWA.
If asbestos is identified, a risk assessment is done and control measures implemented; personnel may stop work and leave the area until declared safe.
Removal and disposal of asbestos is done by a registered asbestos contractor, instructed and paid for by the Employer.
Environmental
Source: NEC - (TSC3) - LV switch gear.pdf
Environmental compliance (Z6.2)
The Contractor must comply with all applicable environmental laws, regulations, rules, guidelines and procedures, and ensure its subcontractors, employees and others under its direction do the same.
Asbestos (Z14)
The Employer manages asbestos and asbestos-containing materials according to its Asbestos Standard 32-303.
If asbestos is identified, a risk assessment is done and control measures implemented; personnel may stop work and leave the area until declared safe.
Removal and disposal of asbestos is done by a registered asbestos contractor, instructed and paid for by the Employer, in line with South African legislation.
Contractual Terms
Source: NEC - (TSC3) - LV switch gear.pdf
Additional conditions of contract (Z1 to Z14)
Z1 Cession, delegation and assignment: the Contractor may not cede, delegate or assign rights or obligations without the Employer's written consent.
Z2 Joint ventures: members are jointly and severally liable; the key person authorised to bind the Contractor must be notified within two weeks of the Contract Date; the composition may not change without consent.
Z3 B-BBEE status: changes must be reported within 7 days; an updated certificate within 30 days; a decrease may lead to renegotiation or termination.
Z4 Confidentiality: contract information must not be disclosed; images of the Affected Property require the Service Manager's prior written consent.
Z5 Waiver and estoppel: extensions, concessions or waivers do not waive rights unless agreed in writing.
Z6 Health, safety and the environment: compliance with the Construction Regulations 2014 and all applicable health, safety and environmental laws.
Z7 Tax invoice and interest: a tax invoice is submitted within one week of the payment certificate; the Employer's VAT number 4740101508 must appear on each invoice.
Z8 Notifying compensation events: a compensation event must be notified within eight weeks of becoming aware of it.
Z9 Employer's limitation of liability: the Employer's liability for the Contractor's indirect or consequential loss is limited to R0.00.
Z10 Termination: a business rescue order against the Contractor is added as a termination ground.
Z11 Ethics: no coercive, collusive, corrupt, fraudulent or obstructive action is permitted; the Employer may terminate if a prohibited action occurs and the Contractor did not act to prevent or remedy it.
Z12 Insurance: the Contractor provides Insurance Table A cover; the Employer provides Insurance Table B cover.
Z13 Nuclear liability: the Employer indemnifies the Contractor against nuclear damage liabilities, except for unlawful intent or unauthorised presence at Koeberg.
Z14 Asbestos: the Employer manages asbestos to its Asbestos Standard 32-303; exposure limits and safe-work procedures apply.
Termination
The Employer may review the contract as business needs require, reduce the number of people, or terminate if the service is no longer required.
The Employer may terminate if Grootvlei Power Station stops operating before the contract expires, or if the contract value is exhausted before the end of the contract period.
Section
Source: NEC - (TSC3) - LV switch gear.pdf
Low service damages (Annexure A)
Penalties apply as a percentage of the issued purchase order value when targets are missed.
Poor workmanship or quality failure: 1% per month of the Task Order value, limited to 5%; the failure is assessed and confirmed within 4 weeks.
SHEQ non-conformance reports: 1% per month of the Task Order value for 1-2 non-conformances; 5% per month for more than 3 non-conformances.
Sets the constitutional standard for fair, equitable, transparent, competitive and cost-effective public procurement.
Relevant because this is a South African public-sector procurement opportunity.
Grootvlei Power Station, between Heidelberg and Villiers next to N3 - Grootvlei - Balfour - 2420
Document-Backed
Source Snapshot Available
AI Enhanced
Source confidence
High source confidence
Official source
eTenders.gov.za
Documents found
8
Last checked
17 Nov 2026
AI status
Enhanced
Data conflicts
None detected
This tender has strong source evidence, including source metadata and supporting tender information synced from the government tender portal.
Tenders SA is not the issuing authority. All tenders are automatically synced from the official government tender portal. Always confirm final submission details, closing dates, briefing sessions, eligibility requirements, and documents on the official government portal before applying.