Broad-Based Black Economic Empowerment Act (B-BBEE Act)
Act 53 of 2003
Provides the empowerment-compliance context often used in public-sector supplier evaluation.
Relevant because this is a South African public-sector procurement opportunity.
Documents available on tender detail page
Tender Type
Request for Bid(Open-Tender)
Delivery Location
393 Witkopies Farm - Olifantsfontein - Centurion - 1665
Organization Type
GOVERNMENT
Published
25 Nov 2026
OCDS Reference
ocds-9t57fa-179816
ESKOM requires a supplier to provide repairs, maintenance and servicing of diesel engines at the apollo and cs grid, apollo converter station and repeater station for a 60-month period. Bids must be submitted electronically through the etendering system, and bidders must have a csd number to access the system. The most consequential consideration is that submission is electronic only, with strict file size limits and a finalisation deadline.
Bidders must have a CSD number to access the eTendering system at https://eTendering.eskom.co.za.
Submission is electronic only; bidders must register, verify their email, and upload documents under the correct category (technical, commercial, finance, etc.).
Each uploaded file must not exceed 50MB, and the total size of all files must not exceed 900MB.
Bidders must finalise the submission by clicking 'Finalize Submission' and then 'Finalise and Close Submission'; the submission timestamp is recorded at finalisation.
After finalisation, a confirmation email with the submission ID is sent; bidders must keep this email for future reference.
Registration details, including name, organisation, CSD number and cellphone number, must be kept current; contact numbers must be entered with a plus prefix (e.g., +27).
For system problems, contact the buyer responsible for the published tender; no specific contact details are provided in the document.
Date & Time
Thursday, 28 January 2027 - 10:00
Venue
https://teams.microsoft.com/meet/3250738149363245?p=i8j4LwMk1G35hRFvPH
Categories
Request for Bid(Open-Tender)
393 Witkopies Farm - Olifantsfontein - Centurion - 1665
AI Document Analysis Stages
Description
25 Nov
2026
Tender Published
Tender was published
28 Jan
2027
Closing Date
Tender closing date
These references help suppliers understand the public-procurement framework around this opportunity. They are generated from the tender category, issuing organisation type and procurement context.
These rules commonly apply to South African public-sector procurement.
Act 53 of 2003
Provides the empowerment-compliance context often used in public-sector supplier evaluation.
Relevant because this is a South African public-sector procurement opportunity.
Act 108 of 1996 (s217)
This is general procurement context, not legal advice. Always verify requirements in the official tender documents and issuing authority notices.
NEC Document.pdf
NTCSA SOC Ltd requires the repair, maintenance and servicing of two standby diesel engines — a Cummins NT 855 G5 at Apollo Converter Station and a Deutz F4L 912 at Pietersburg Repeater Station — under a 60-month NEC3 Term Service Contract. Work is priced on a price list (Option A) covering yearly services and as-and-when repairs, with call-out fees and preliminary deliverables.
240-70044602 OHS Baseline risk assessment.xlsx
Repairs, maintenance and service of diesel engines at Apollo & CS Grid, Apollo Converter Station and Repeater Station over a 60-month period, for Eskom's Apollo & Centralised Services business unit in Gauteng. The pack carries the contractor baseline occupational health and safety risk assessment template that governs how the work is executed on site.
Annexure B Acknowledgement form.docx
Repairs, maintenance and servicing of diesel engines at the Apollo and CS Grid, Apollo Converter Station and Repeater Station for a 60-month period, issued by Eskom.
240-105658000 Supplier Quality Management Specification (3).pdf
Eskom requires the repair, maintenance and servicing of diesel engines at Apollo & CS Grid, Apollo Converter Station and Repeater Station over a 60-month period. Suppliers must operate a quality management system conforming to ISO 9001 and meet Eskom's supplier quality requirements, which are graded across four categories.
240-109253698 CQP Template 2021.docx
Repairs, maintenance and service of diesel engines at Apollo & CS Grid, Apollo Converter Station and Repeater Station for Eskom over a 60-month period. Bidders must submit a Contract Quality Plan built on the supplied template and referenced to SANS 466:2005 Edition 1 / ISO 10005:2005 Edition 2.
Invitation to tender for maintenance of diesel engines.pdf
Repairs, maintenance and servicing of diesel engines at Apollo & CS Grid, Apollo Converter Station and Repeater Station for a 60-month period, issued by NTCSA (Eskom transmission subsidiary).
Maintenance and Repairs of Diesel Engines_Tender BOQ.xlsx
Eskom requires service, maintenance, and repairs of diesel engines at the Apollo Converter Station and the Pietersburg Repeater Station for a 60-month period. The contract is an NEC3 TSC3 term service contract, priced via a bill of quantities with a final summary.
OHS Specification - Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station .pdf
Eskom NTCSA requires a contractor to repair, maintain and service diesel engines at Apollo Converter Station, the Apollo and Centralised Services grid, and the repeater station over a 60-month period. The work is governed by an occupational health and safety specification that sets the minimum legislative and Eskom NTCSA requirements the contractor and its appointed contractors must meet for the duration of the contract.
Non-Construction Site Readiness Checklist NTCSA.docx
Eskom requires the repair, maintenance and service of diesel engines at the Apollo and CS Grid sites, the Apollo Converter Station and the Repeater Station, under a contract running for 60 months. Bidders must be able to demonstrate a complete and compliant health and safety file before work may start on site.
SoW- Service Maintenance Repairs of Diesel Engines for Apollo Converter Station2025.pdf
Repairs, maintenance and servicing of diesel engines at Apollo Converter Station and Pietersburg Repeater Station for a 60-month period, under the National Transmission Company South Africa SOC Ltd (Apollo & CS Grid).
TEC-Service Maintenance_Diesel Engine Technical Criteria_17.06.2026.pdf
Service, maintenance and repairs of diesel engines and generators at Apollo Converter Station, covering preventative maintenance at predetermined intervals, for the Apollo and Centralised Services (CS) business unit of National Transmission Company South Africa SOC Ltd. The contract runs for 60 months and bids close on 28 January 2027 at 10:00.
SDL&I Inputs Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station.pdf
Repairs, maintenance and service of diesel engines at Apollo & CS Grid, Apollo Converter Station and Repeater Station, contracted for 60 months (5 years) under NTCSA's Transmission business unit. The work is a re-issued tender with a closing date of 28 January 2027 at 10:00.
240-109253302 _ Quality Control Plan or Inspection Test Plan (QCP or ITP) rev 2.docx
Repairs, maintenance and servicing of diesel engines across three Eskom sites — Apollo & CS Grid, Apollo Converter Station and Repeater Station — under a 60-month contract. The work is governed by a quality control plan in which the contractor, subcontractor, Eskom and, where applicable, an Approved Inspection Authority each hold defined intervention points.
CONTRACTOR SHE plan ANNEXURE D.docx
Repairs, maintenance and service of diesel engines at Apollo & CS Grid, Apollo Converter Station and Repeater Station over a 60-month period. The work is re-issued by Eskom in Gauteng and requires bidders to submit a SHE plan covering the full list of prescribed health, safety and environmental elements.
NTCSA_E-Tenderers E-Tendering Training Acknowledgement Form.docx
Eskom requires the repair, maintenance and servicing of diesel engines at Apollo & CS Grid, Apollo Converter Station and Repeater Station over a 60-month period. The procurement is a re-issue and is run through Eskom's e-Tendering solution.
240-12248652_List of Tender Returnables_Cat 3_ Rev 7.pdf
Eskom requires the repair, maintenance and service of diesel engines at Apollo & CS Grid, Apollo Converter Station and Repeater Station over a 60-month period. Bidders must submit a set of quality management returnables, assessed against a total score of 13 across five sections. The tender closes on 28 January 2027 at 10:00.
NTCSA_E-tendering Help Manual for supplier.docx
Eskom requires the repair, maintenance and servicing of diesel engines at Apollo & CS Grid, Apollo Converter Station and Repeater Station over a 60-month period. Bids are submitted electronically through the Eskom eTendering portal.
To download these documents and access AI-powered analysis, visit the main tender page.
Organization
EskomWin Eskom tenders with AI Tender Matching, technical document analysis, compliance scoring, and structured bid support for energy and engineering contracts.
Matched by category & region
Free guidance to prepare before you bid
Not sure if your business is ready for this tender? Check CSD, CIDB, and B-BBEE requirements, run a readiness assessment, and move from opportunity to submission.
Open Supplier Readiness HubMedian Estimate
R 3 680 000
Range
Based on SITA benchmarks. Companies with similar profiles typically bid near the median.
* Estimates are based on historical data and do not guarantee actual award values.
We refine every tender document through these stages so you can brief your team and prepare your bid with confidence. Anything marked as "in progress" will be upgraded automatically — no action required from you.
This document is Eskom's Supplier Quality Management Specification (240-105658000, Revision 3), which applies to all Eskom suppliers and sub-suppliers. It sets the minimum quality requirements for selection, evaluation, vendor registration, management, monitoring, assessment and auditing of suppliers. The specification is based on ISO 9001 and applies to all Eskom RFIs, RFQs, RFPs, and contracts for procurement of products and services.
Important Dates
Source: 240-105658000 Supplier Quality Management Specification (3).pdf (unknown)Closing date: 28 January 2027 at 08:00 (from tender record).
No other dates are stated in the document.
Contact Information
Source: 240-105658000 Supplier Quality Management Specification (3).pdf (unknown)No specific contact details are provided in the document.
Submission Guidelines
Source: 240-105658000 Supplier Quality Management Specification (3).pdf (unknown)Returnable documents:
Evaluation Criteria
Source: 240-105658000 Supplier Quality Management Specification (3).pdf (unknown)Quality assessment criteria are selected and completed by an Eskom Quality representative using Form A. The supplier must complete and sign Form A to acknowledge and accept Eskom Supplier Quality requirements as per this specification and ISO 9001.
Technical Specifications
Source: 240-105658000 Supplier Quality Management Specification (3).pdf (unknown)This document is Eskom's Supplier Quality Management Specification (240-105658000, Revision 3), which applies to all Eskom suppliers and sub-suppliers. It sets the minimum quality requirements for selection, evaluation, vendor registration, management, monitoring, assessment and auditing of suppliers.
Methodology
Source: 240-105658000 Supplier Quality Management Specification (3).pdfMethod statements and execution plans:
Experience & Qualifications
Source: 240-105658000 Supplier Quality Management Specification (3).pdfQuality audits and related quality performance reviews must be carried out by trained, accredited, and experienced personnel in accordance with documented procedures.
Quality Management
Source: 240-105658000 Supplier Quality Management Specification (3).pdfQuality management system requirements:
Pricing Schedule
Source: 240-105658000 Supplier Quality Management Specification (3).pdfNo specific pricing schedule, rates, bill of quantities, or payment schedules are stated in this document.
Financial Requirements
Source: 240-105658000 Supplier Quality Management Specification (3).pdf (unknown)No specific financial requirements (pricing format, bid security, bonds, guarantees, retention, payment terms, turnover) are stated in the document.
Compliance Requirements
Source: 240-105658000 Supplier Quality Management Specification (3).pdf (unknown)ISO 9001 certification is required unless excluded by the quality category (see submission guidelines).
Health & Safety
Source: 240-105658000 Supplier Quality Management Specification (3).pdfThe document references Eskom's Safety, Health, Environment, and Quality (SHEQ) Policy (32-727) as an informative reference. No specific health and safety requirements are detailed in this specification.
Contractual Terms
Source: 240-105658000 Supplier Quality Management Specification (3).pdfPreservation management programme requirements:
Description
Source: SoW- Service Maintenance Repairs of Diesel Engines for Apollo Converter Station2025.pdfApollo Converter Station forms part of the Cahora Bassa HVDC scheme, rated at 1800 MW and a key asset in the Eskom power system. Diesel engines are integrated into the scheme at two sites:
Annual servicing keeps the engines functional and performing efficiently; breakdowns require fault finding and repair to restore them to working order. The work sits under the Apollo and CS business unit, Apollo & CS Grid Maintenance, and takes effect from February 2026.
Evaluation Criteria
Source: SoW- Service Maintenance Repairs of Diesel Engines for Apollo Converter Station2025.pdf (unknown)Technical evaluation criterion
Technical Specifications
Source: SoW- Service Maintenance Repairs of Diesel Engines for Apollo Converter Station2025.pdf (unknown)Scope
Equipment covered
Execution
Quality Management
Source: SoW- Service Maintenance Repairs of Diesel Engines for Apollo Converter Station2025.pdfQuality assurance
Outputs
Compliance Requirements
Source: SoW- Service Maintenance Repairs of Diesel Engines for Apollo Converter Station2025.pdf (unknown)Accreditation
Legislation and standards
Health & Safety
Source: SoW- Service Maintenance Repairs of Diesel Engines for Apollo Converter Station2025.pdfSafety and compliance
Section
Source: SoW- Service Maintenance Repairs of Diesel Engines for Apollo Converter Station2025.pdfTechnical evaluation criterion
Description
Source: Annexure B Acknowledgement form.docxThe tender is for repairs, maintenance and service of diesel engines at the Apollo Converter Station and Repeater Station, and the Apollo & CS Grid, for a period of 60 months.
Evaluation Criteria
Source: Annexure B Acknowledgement form.docx (unknown)Bidders must sign and submit Annexure B (Acknowledgement Form for Eskom OHS legal and other requirements) as part of the bid. The form must be signed by an authorised person (CEO, Director or Managing Director) and witnessed by two witnesses. Signing confirms the bidder has obtained and understood the listed OHS documents and accepts the consequences of non-compliance.
Technical Specifications
Source: Annexure B Acknowledgement form.docx (unknown)The tender is for repairs, maintenance and service of diesel engines at the Apollo Converter Station and Repeater Station, and the Apollo & CS Grid, for a period of 60 months.
Compliance Requirements
Source: Annexure B Acknowledgement form.docx (unknown)OHS compliance obligations after contract award:
Evaluation Criteria
Source: Non-Construction Site Readiness Checklist NTCSA.docx (unknown)The contractor's health and safety file must be in order before work can start on site.
A Section 37(2) agreement signed by both the client and the principal contractor must be on file.
A current COID letter of good standing from the Compensation Fund or a licensed insurer must be provided, with registration number and expiry date.
Where subcontractors are used, their health and safety plans must be approved by the principal contractor and their site health and safety files must conform to all relevant requirements.
Compliance Requirements
Source: Non-Construction Site Readiness Checklist NTCSA.docx (unknown)The contractor must provide a current COID letter of good standing from the Compensation Fund or a licensed insurer, including registration number and expiry date.
The contractor must have a Section 37(2) agreement signed by both the client and the principal contractor.
The contractor must have a health and safety file in order before work can start on site.
The contractor must provide medical certificates for all employees on site.
The contractor must provide a list of employees on site (names and designations).
The contractor must provide a health and safety plan according to the client's health and safety specification and scope of work.
The contractor must provide a SHEQ policy.
The contractor must provide appointments for designated employer, health and safety representatives (if more than 20 employees), chairman of health and safety committee, incident/accident investigator, supervisor, risk assessor, first aider, fire fighter/warden, and fall protection planner/developer, with relevant training certificates.
The contractor must provide risk assessments (baseline and task-specific), method statements, and job observation templates.
The contractor must provide induction training syllabus, training matrix, and attendance register.
The contractor must provide fall protection risk assessment, medical fitness evaluation, training program, inspection/testing/maintenance procedures, and rescue plan.
The contractor must provide lifting equipment competency and load testing records.
The contractor must provide employee medicals, competency for tools and equipment, maintenance records, and inspection templates.
The contractor must provide list of chemical agents, safety data sheets, emergency plan, incident management procedure and templates, PPE procedure and issue register.
Description
Source: CONTRACTOR SHE plan ANNEXURE D.docxThe SHE plan must demonstrate management's commitment to SHE and include the minimum elements listed in the technical specifications.
Evaluation Criteria
Source: CONTRACTOR SHE plan ANNEXURE D.docx (unknown)The SHE plan will be evaluated on the following elements:
Technical Specifications
Source: CONTRACTOR SHE plan ANNEXURE D.docx (unknown)The SHE plan must demonstrate management's commitment to SHE and include, as a minimum, the following elements:
Compliance Requirements
Source: CONTRACTOR SHE plan ANNEXURE D.docx (unknown)The SHE plan must include a letter of good standing with a compensation insurer. OHS professionals must be registered where legislation requires. SHE competencies for SHE personnel and supervisors must be demonstrated.
Description
Source: Invitation to tender for maintenance of diesel engines.pdfThe tender is for repairs, maintenance and service of diesel engines at Apollo & CS Grid, Apollo Converter Station and Repeater Station, for a period of 60 months. The contract will be awarded to a single supplier for the whole contract. The enquiry documents are free of charge. The Standard Conditions of Tender are available at www.ntcsa.co.za.
Important Dates
Source: Invitation to tender for maintenance of diesel engines.pdf (TENDER)Closing date: 28 January 2027 at 10:00 SAST
Clarification meeting (non-compulsory): 12 January 2027 at 11:00, via Microsoft Teams (link provided in the tender; confirm attendance with the NTCSA Representative)
Clarification queries deadline: 10 working days before the tender closing date
Tender validity period: 90 days from closing date
Contact Information
Source: Invitation to tender for maintenance of diesel engines.pdf (TENDER)NTCSA Representative:
1st escalation – Procurement Manager:
2nd escalation – Middle Manager:
Submission portal: https://tenderbulletin.ntcsa.co.za
Submission Guidelines
Source: Invitation to tender for maintenance of diesel engines.pdf (TENDER)Submission method: electronic only, via the NTCSA Tender Bulletin on the Eskom e-tendering site (https://tenderbulletin.ntcsa.co.za). No hard copies accepted. No zip/compressed files. Upload each document under the correct folder (Technical, Commercial, Financial, Other). All documents in PDF format; the price list must also be submitted in Excel format. Maximum upload size per document is 500 MB; total submission limited to 4 GB. If resubmitting, only the latest version is considered; earlier versions are void. Late tenders are not accepted.
Returnable forms (must be completed, signed where required, and submitted by closing time unless noted):
Non-disqualifiable returnables (SBD 4, CIDB proof where permitted) may be requested within 5 working days after closing; CIDB proof may be allowed up to 21 working days after closing only if expressly permitted. Failure to submit within the allowed period leads to disqualification.
Returnables required for evaluation (not disqualifying but score zero if missing): Specific Goals evidence (B-BBEE status level certificate/affidavit).
Evaluation Criteria
Source: Invitation to tender for maintenance of diesel engines.pdf (TENDER)Evaluation stages:
Functionality criteria (total 100%):
Failure to submit evidence for a Specific Goal results in 0 points for that goal, but not disqualification.
Technical Specifications
Source: Invitation to tender for maintenance of diesel engines.pdf (TENDER)Scope: Repairs, maintenance and service of diesel engines at Apollo & CS Grid, Apollo Converter Station and Repeater Station, for a period of 60 months.
Key requirements:
Pricing Schedule
Source: Invitation to tender for maintenance of diesel engines.pdfPricing Schedule/BOQ is attached in the tender advert (Commercial Folder). Prices are evaluated inclusive of VAT, corrected for arithmetical errors, and compared on Net Present Value basis. Unconditional discounts are considered; conditional discounts applied at payment. Prices scored out of 80 points. Alternative tenders are not allowed. Cataloguing line item may be required (NTCSA pays). Provision of security for performance: not applicable. Objective criteria: for ME class of works, applicable percentage is 0.25% (contained in BOQ/Pricing schedule).
Financial Requirements
Source: Invitation to tender for maintenance of diesel engines.pdf (TENDER)Payment terms:
Pricing:
Compliance Requirements
Source: Invitation to tender for maintenance of diesel engines.pdf (TENDER)Mandatory (disqualifying if not met):
Additional (where applicable):
Health & Safety
Source: Invitation to tender for maintenance of diesel engines.pdfSafety requirements:
Environmental
Source: Invitation to tender for maintenance of diesel engines.pdfEnvironmental documents as required per scope of works are attached in the tender advert Environmental Folder.
Contractual Terms
Source: Invitation to tender for maintenance of diesel engines.pdfContract type: NEC3 Term Service Contract (TSC3).
Payment terms:
CIDB requirements:
Eligibility exclusions:
Insurance deductibles and list of acceptable guarantors: not applicable.
Section
Source: Invitation to tender for maintenance of diesel engines.pdfAdditional evaluation details:
Description
Source: Maintenance and Repairs of Diesel Engines_Tender BOQ.xlsxThe pricing schedules are locked except for the rate column; bidders must enter rates only.
Submission Guidelines
Source: Maintenance and Repairs of Diesel Engines_Tender BOQ.xlsx (unknown)Returnable documents: the completed pricing schedules (Annexure IT 5.1) and the final summary, with the tenderer's name and category of offer (main) filled in. The pricing schedules must be completed in the rate column only; all other cells are locked.
Evaluation Criteria
Source: Maintenance and Repairs of Diesel Engines_Tender BOQ.xlsx (unknown)Bidders must complete the pricing schedules (Annexure IT 5.1) and the final summary. The tenderer's name and category of offer (main) must be provided. No other eligibility criteria (e.g., CSD registration, tax clearance, B-BBEE level) are stated in the extracted document.
Technical Specifications
Source: Maintenance and Repairs of Diesel Engines_Tender BOQ.xlsx (unknown)Service, maintenance and repairs of diesel engines at Apollo Converter Station and Pietersburg Repeater Station.
Financial Requirements
Source: Maintenance and Repairs of Diesel Engines_Tender BOQ.xlsx (unknown)Pricing must be submitted in ZAR, excluding VAT. The final summary includes preliminaries and generals, maintenance and repairs, sub-total (excl. VAT), VAT (15%), and total (incl. VAT).
Submission Guidelines
Source: NTCSA_E-Tenderers E-Tendering Training Acknowledgement Form.docx (unknown)Returnable documents:
Disqualification risks:
Evaluation Criteria
Source: NTCSA_E-Tenderers E-Tendering Training Acknowledgement Form.docx (unknown)Bidders must have completed e-Tendering self-training and confirm they can operate the E-Tendering Solution. The E-Tendering Training Acknowledgement Form is a mandatory returnable; an incomplete form or late submission disqualifies the bid.
Description
Source: OHS Specification - Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station .pdfThe NTCSA Division of Eskom NTCSA is responsible for planning, operating and maintaining NTCSA assets, providing access to the interconnected NTCSA system, and influencing customer demand and behaviour. The division develops plans and engineering solutions for expansion, maintenance and refurbishment of the power network, and executes projects for capital expansion, strengthening and refurbishment of NTCSA assets.
This OHS specification sets out the minimum requirements that must be met by contractors for the duration of the contract. The contractor is expected to develop an OHS plan that meets these requirements and all applicable legislation. The specification is not all-encompassing and does not supersede or replace any organisational OHS requirements.
Important Dates
Source: OHS Specification - Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station .pdf (unknown)Closing date: 29 April 2026 (as stated in the OHS specification; the tender record lists 28 January 2027 at 08:00 as the closing date).
Briefing session: No date, time, or venue provided.
Evaluation Criteria
Source: OHS Specification - Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station .pdf (unknown)Preconditions to bid and to commence work:
Evaluation is a three-stage process: evaluation of the risks; evaluation of the contractor's OHS plan; and evaluation of the contractor's compliance with the OHS specification.
Technical Specifications
Source: OHS Specification - Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station .pdf (unknown)The contract is for the service, maintenance and repairs of diesel engines at Apollo Converter Station and the Apollo & Centralised Services grid, including the repeater station, for a period of 60 months.
The contractor must develop an OHS plan that meets the requirements of this specification and all applicable legislation.
The contractor remains accountable for the quality and execution of its health and safety programme for its employees and appointed contractor employees.
All requirements listed in the specification are minimum requirements and do not supersede or replace any organisational OHS requirements.
Experience & Qualifications
Source: OHS Specification - Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station .pdfThe contractor must appoint competent staff with the necessary knowledge, training, experience and qualifications for the work. A full-time safety officer or construction safety officer registered with SACPCMP must be appointed. Medical fitness examinations must be conducted by a registered Occupational Health Practitioner.
Quality Management
Source: OHS Specification - Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station .pdfContractors must comply with Eskom NTCSA's Substance Abuse Procedure (32-37). The alcohol and drug permissible level is 0%. Anyone entering Eskom NTCSA premises is subject to ad hoc alcohol testing. Test records must be treated as confidential and filed in the employee's personal file.
Compliance Requirements
Source: OHS Specification - Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station .pdf (unknown)No specific compliance requirements found in the document.
Health & Safety
Source: OHS Specification - Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station .pdfThe contractor must comply with the OHS specification, which includes requirements for:
Environmental
Source: OHS Specification - Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station .pdfThe contractor must comply with environmental legislation, including the National Environmental Management Act, Environment Conservation Act, National Water Act, and other applicable laws. An Environmental Management Plan should be prepared and adhered to, minimising negative environmental impacts. The contractor has a duty of care to the environment and must take reasonable measures to prevent pollution or degradation.
Description
Source: NTCSA_E-tendering Help Manual for supplier.docxThe document is a user manual for the eTendering system, which replaces physical submission of tender documents at Eskom offices. It explains how suppliers register, log in, upload tender documents, and finalise submissions. No details about the diesel engine repair services are included.
Submission Guidelines
Source: NTCSA_E-tendering Help Manual for supplier.docx (unknown)Submission is electronic only via the eTendering system at https://eTendering.eskom.co.za. Bidders must register on the system and verify their email address. Each uploaded file must not exceed 50MB, and the total size of all files must not exceed 900MB. Upload documents under the correct category (technical, commercial, finance, etc.). Finalise the submission by clicking 'Finalize Submission' and then 'Finalise and Close Submission'. After finalisation, a confirmation email with the submission ID is sent; keep this email for future reference. The submission timestamp is recorded at finalisation.
Evaluation Criteria
Source: NTCSA_E-tendering Help Manual for supplier.docx (unknown)No evaluation criteria are stated in the provided document. The document only describes the eTendering submission process.
Technical Specifications
Source: NTCSA_E-tendering Help Manual for supplier.docx (unknown)The document is a user manual for the eTendering system, not a specification of the diesel engine repair services. It describes how to register, log in, upload tender documents, and finalise submissions. No technical requirements for the diesel engines are provided.
Compliance Requirements
Source: NTCSA_E-tendering Help Manual for supplier.docx (unknown)A CSD (Central Supplier Database) number is required to gain access to the eTendering system. Registration details, including name, organisation, CSD number and cellphone number, must be kept current. Contact numbers must be entered with a plus prefix, for example +27.
Description
Source: 240-109253698 CQP Template 2021.docxThe tender is for repairs, maintenance and service of diesel engines at Apollo and CS Grid, Apollo Converter Station and Repeater Station, for a period of 60 months. The document provided is a Contract Quality Plan (CQP) template that the supplier must complete and submit.
Technical Specifications
Source: 240-109253698 CQP Template 2021.docx (unknown)The tender is for repairs, maintenance and service of diesel engines at Apollo and CS Grid, Apollo Converter Station and Repeater Station, for a period of 60 months. The document provided is a Contract Quality Plan (CQP) template that the supplier must complete and submit. The CQP must cover:
Compliance Requirements
Source: 240-109253698 CQP Template 2021.docx (unknown)The supplier must complete and submit the Contract Quality Plan (CQP) template. The CQP must be compiled by a representative from the tenderer and approved by the owner of the organisation. The CQP must be revised from Rev 0 during tender evaluation to Rev 1 after contract signing. Eskom approval is required after award.
Description
Source: TEC-Service Maintenance_Diesel Engine Technical Criteria_17.06.2026.pdfThis document sets out the technical evaluation criteria for the service, maintenance and repairs of diesel engines and generators at Apollo Converter Station (Apollo CS). It applies to the Apollo and Centralised Services (CS) business unit of the National Transmission Company South Africa SOC Ltd. The document is effective from its approval date. The most recent edition of the Tender Engineering Evaluation Procedure (240-48929482) is a normative reference. Informative references include ISO 9001 Quality Management Systems, the Guide to Integrated Risk Management (Eskom Ltd, 2009), and the Occupational Health and Safety Act, 1993 (Act No. 85).
Evaluation Criteria
Source: TEC-Service Maintenance_Diesel Engine Technical Criteria_17.06.2026.pdf (unknown)Technical evaluation is performed by appointed members of a cross-functional team against functionality criteria. Minimum qualifying threshold: 70%.
Scoring breakdown (total 100%):
Technical Specifications
Source: TEC-Service Maintenance_Diesel Engine Technical Criteria_17.06.2026.pdf (unknown)Scope: Service, maintenance and repairs of diesel engines and generators at Apollo Converter Station (Apollo CS), under the Apollo and Centralised Services (CS) business unit of the National Transmission Company South Africa SOC Ltd.
Applicability: Apollo Converter Station.
References: The most recent edition of the Tender Engineering Evaluation Procedure (240-48929482) applies. Informative references include ISO 9001 Quality Management Systems, the Guide to Integrated Risk Management (Eskom Ltd, 2009), and the Occupational Health and Safety Act, 1993 (Act No. 85).
Experience & Qualifications
Source: TEC-Service Maintenance_Diesel Engine Technical Criteria_17.06.2026.pdfBidders must demonstrate relevant experience and technical expertise for diesel engine maintenance and repair services.
Experience and reputation:
Technical expertise:
Years of experience:
Workshop or service capability:
Compliance Requirements
Source: TEC-Service Maintenance_Diesel Engine Technical Criteria_17.06.2026.pdf (unknown)No mandatory support documentation is required for the technical evaluation.
Informative references include ISO 9001 Quality Management Systems and the Occupational Health and Safety Act, 1993 (Act No. 85).
Health & Safety
Source: TEC-Service Maintenance_Diesel Engine Technical Criteria_17.06.2026.pdfThe Occupational Health and Safety Act, 1993 (Act No. 85) is listed as an informative reference, indicating that bidders should be aware of and comply with OHS requirements relevant to the work.
Submission Guidelines
Source: 240-109253302 _ Quality Control Plan or Inspection Test Plan (QCP or ITP) rev 2.docx (unknown)Returnable documents: the Quality Control Plan / Inspection Test Plan (QCP or ITP) must be completed and submitted. The form requires contract/order numbers, scope of work, item/plant/material description, revision number and date, and approval signatures from the contractor/supplier, subcontractor (where applicable), Eskom, and any Approved Inspection Authority. Intervention points (hold, witness, document review, surveillance, verification) and inspection/test methods must be defined.
Technical Specifications
Source: 240-109253302 _ Quality Control Plan or Inspection Test Plan (QCP or ITP) rev 2.docx (unknown)Scope of work: repairs, maintenance and service of diesel engines at Apollo and CS Grid, Apollo Converter Station and Repeater Station, for a period of 60 months. The QCP/ITP must detail activities, inspection and test methods (e.g. visual, microscopy, NDT, liquid/dye penetrant, magnetic particle, eddy current), controlling documents, acceptance criteria (e.g. functionality, performance measures, regulatory compliance, chemical test), and records. Statutory vs non-statutory activities must be indicated.
Compliance Requirements
Source: 240-109253302 _ Quality Control Plan or Inspection Test Plan (QCP or ITP) rev 2.docx (unknown)The QCP/ITP must be approved by the contractor/supplier and Eskom; where applicable, an Approved Inspection Authority (AIA) and Notification Body (NOBO) or Third Party Inspection (TPI) may be involved. No other compliance requirements are stated.
Description
Source: SDL&I Inputs Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station.pdfService, maintenance and repairs of diesel engines at Apollo Converter Station and repeater station, for a period of 5 years.
Evaluation Criteria
Source: SDL&I Inputs Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station.pdf (TENDER)CIDB grading: Level 1 ME or higher.
Preference points: valid B-BBEE certificate issued by a SANAS accredited verification agency, sworn affidavit, or CIPC affidavit.
B-BBEE evidence thresholds: annual total revenue of R10 million or less qualifies as an Exempted Micro Enterprise and a sworn affidavit may be submitted; revenue of R50 million or less qualifies as a Qualifying Small Enterprise, which must comply with all QSE scorecard elements relevant to its sector unless at least 51% black owned, in which case a sworn affidavit is required; revenue above R50 million requires a valid B-BBEE certificate.
Sworn affidavit validity: the deponent's name and identity number, designation, enterprise name and business address, black ownership percentages, total revenue and its basis, financial year end, B-BBEE status level, empowering supplier status, and matching signature and commissioning dates must all be reflected, and the Commissioner of Oath may not be an employee or ex officio of the enterprise.
Designated sector: not applicable. SBD 6.2 Declaration Form and Annex C (Local Content Declaration – Summary Schedule) are mandatory on contract award.
Mandatory subcontracting and the National Industrial Participation Programme do not apply.
Technical Specifications
Source: SDL&I Inputs Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station.pdf (TENDER)Scope: Service, maintenance and repairs of diesel engines at Apollo Converter Station and repeater station.
Duration: 5 years.
Pricing Schedule
Source: SDL&I Inputs Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station.pdfLocal procurement content: total spending minus imported component. Tender response must be separated into components as per the Price Schedule.
Financial Requirements
Source: SDL&I Inputs Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station.pdf (TENDER)Local procurement content: total spending minus the imported component. Where a contract combines local and imported goods/services, the tender response must be separated into components as per the Price Schedule.
SDL&I penalty: 2.5% of the invoice amount for failure to meet SDL&I obligations.
SDL&I retention: 2.5% of every invoice (excluding VAT) retained as security for SDL&I obligations, released upon receipt of progress reports, fulfilment of obligations, and submission of an approved compliance report.
Compliance Requirements
Source: SDL&I Inputs Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station.pdf (TENDER)B-BBEE: valid certificate or sworn affidavit required as condition for contract award. Thresholds as per evaluation criteria.
CIDB: Level 1 ME or higher.
SBD 6.2 Declaration Form and Annex C (Local Content Declaration – Summary Schedule) mandatory on contract award.
SDL&I objectives: B-BBEE improvement or retention plan must be submitted within 30 days of signing the contract. Level 4 bidders must reach Level 3 by end of first year; Level 5-8 or non-compliant bidders must reach Level 4 by end of first year and improve one level each subsequent year.
Local procurement content target: 100%.
Jobs: proposals required for type and number of jobs created and retained in South Africa.
Reporting: quarterly SDL&I reports; SDL&I Implementation Schedule to be completed and returned within 28 days after contract award.
Section
Source: SDL&I Inputs Service, Maintenance & Repairs of Diesel Engines for Apollo Converter Station.pdfPreference points allocated based on B-BBEE status. B-BBEE improvement or retention plan requested. B-BBEE evidence thresholds as per evaluation criteria.
Description
Source: NEC Document.pdfThe contract covers maintenance and service of diesel engines at Apollo & CS Grid, Apollo Converter Station and Repeater Station. The contract is an NEC3 Term Service Contract (TSC3) with a 5-year service period.
Important Dates
Source: NEC Document.pdf (unknown)Closing date: 28 January 2027 at 08:00.
No briefing or site visit dates are stated in the document.
Contact Information
Source: NEC Document.pdf (unknown)Service Manager:
Employer:
Employer's representative (signatory):
Submission Guidelines
Source: NEC Document.pdf (unknown)Submission method: not stated in the document.
Closing time: 28 January 2027 at 08:00 (from tender record).
Returnable documents:
Disqualification risks:
Evaluation Criteria
Source: NEC Document.pdf (unknown)Evaluation approach: not stated in the document.
Preference points system: not stated.
Minimum qualifying score: not stated.
Contract conditions affecting evaluation:
Technical Specifications
Source: NEC Document.pdf (unknown)Scope: Maintenance, service and repair of diesel engines and diesel pumps at Apollo Converter Station and the Pietersburg Repeater Station.
Contract period: 5 years (60 months).
Services include:
Equipment details:
Frequency: As and when required service.
Deliverables:
Working on site:
Experience & Qualifications
Source: NEC Document.pdfKey personnel:
Quality Management
Source: NEC Document.pdfQuality assurance requirements are referenced in the Scope of Work (section 3.3) but details are not provided in the extracted text. The contractor must submit maintenance reports upon completion of work, highlighting all repairs completed and tests conducted.
Pricing Schedule
Source: NEC Document.pdfPricing format: Option A – Priced contract with price list.
Price list items:
Pricing assumptions:
Financial Requirements
Source: NEC Document.pdf (unknown)Pricing format: Option A – Priced contract with price list (lump sums and/or rates multiplied by quantities).
Price list items:
Payment terms:
Liability:
Insurance:
Bonds/guarantees: not stated in the document.
Compliance Requirements
Source: NEC Document.pdf (unknown)CIDB registration: The tenderer's CIDB registration number must be stated on the Form of Offer and Acceptance.
B-bbee:
Tax compliance: Not explicitly stated, but tax invoice requirements apply (VAT number 4710303126).
Joint ventures: If bidding as a joint venture, consortium or other unincorporated grouping, the grouping is jointly and severally liable; must notify the Service Manager within two weeks of the Contract Date of the key person authorised to bind the grouping; may not alter composition without written consent.
Cession/assignment: Not permitted without the Employer's written consent.
Ethics: Prohibited actions (coercive, collusive, corrupt, fraudulent, obstructive) may lead to termination.
Health and safety:
Environmental:
Asbestos:
Nuclear liability: Employer indemnifies contractor against nuclear damage (except unlawful intent or unauthorised presence at Koeberg).
Health & Safety
Source: NEC Document.pdfHealth and safety obligations:
Environmental
Source: NEC Document.pdfEnvironmental obligations:
Contractual Terms
Source: NEC Document.pdfContract type: NEC3 Term Service Contract (TSC3) with main Option A (priced contract with price list) and secondary Options X1 (price adjustment for inflation), X2 (changes in law), X17 (low service damages), X18 (limitation of liability), X19 (task order), X20 (key performance indicators), and Z (additional conditions).
Duration: 5 years.
Law and language: Law of South Africa; English.
Dispute resolution: Option W1 – Adjudicator from ICE-SA Panel, or appointed by AFSA; arbitration under Association of Arbitrators (Southern Africa) rules.
Termination: Employer may terminate for prohibited actions, business rescue order, or B-BBEE status decrease.
Confidentiality: Contractor must not disclose information; images of the Affected Property require prior written consent.
Waiver: No waiver unless agreed in writing.
Compensation events: Contractor must notify within 8 weeks of becoming aware, or loses entitlement to price change.
Insurance: Contractor provides insurances per Table A; Employer provides per Table B.
Nuclear liability: Employer indemnifies contractor against nuclear damage (except unlawful intent or unauthorised presence).
Asbestos: Employer manages asbestos; contractor may stop work if asbestos is identified; removal by registered contractor at Employer's expense.
Section
Source: NEC Document.pdfThe document does not specify evaluation criteria beyond the general conditions. Quality assurance requirements are referenced in the Scope of Work (section 3.3) but details are not provided in the extracted text.
Description
Source: 240-12248652_List of Tender Returnables_Cat 3_ Rev 7.pdfThe tender covers service, maintenance and repairs of diesel engines for the Apollo Converter Station, including the Apollo & CS Grid and Repeater Station, for a period of 60 months.
Submission Guidelines
Source: 240-12248652_List of Tender Returnables_Cat 3_ Rev 7.pdf (TENDER)Returnable documents (Category 3 quality requirements) must be submitted with the bid:
Evaluation Criteria
Source: 240-12248652_List of Tender Returnables_Cat 3_ Rev 7.pdf (TENDER)Quality requirements are evaluated as deliverables (indicator = 1). Sections and scores:
Total possible quality score: 13 points. Bidders must provide objective evidence of a documented QMS that complies with ISO 9001; certification is not required.
Technical Specifications
Source: 240-12248652_List of Tender Returnables_Cat 3_ Rev 7.pdf (TENDER)Scope of work: service, maintenance and repairs of diesel engines for the Apollo Converter Station, including the Apollo & CS Grid and Repeater Station, for a period of 60 months.
Compliance Requirements
Source: 240-12248652_List of Tender Returnables_Cat 3_ Rev 7.pdf (TENDER)No specific compliance requirements beyond the quality returnables listed in submission guidelines.
Section
Source: 240-12248652_List of Tender Returnables_Cat 3_ Rev 7.pdfQuality requirements are evaluated as deliverables (indicator = 1). Sections and scores:
Total possible quality score: 13 points. Bidders must provide objective evidence of a documented QMS that complies with ISO 9001; certification is not required.
Sets the constitutional standard for fair, equitable, transparent, competitive and cost-effective public procurement.
Relevant because this is a South African public-sector procurement opportunity.
Act 5 of 2000
Covers preferential procurement and preference-point systems used in public tenders.
Relevant because this is a South African public-sector procurement opportunity.
Act 12 of 2004
Supports anti-corruption controls and supplier integrity in procurement processes.
Relevant because this is a South African public-sector procurement opportunity.
Act 28 of 2024
Provides the national framework for public procurement across government.
Relevant because this is a South African public-sector procurement opportunity.
Act 2 of 2000
Supports access to tender records, award decisions and public-sector procurement information.
Relevant because this is a South African public-sector procurement opportunity.
Act 3 of 2000
Supports lawful, reasonable and procedurally fair administrative tender decisions.
Relevant because this is a South African public-sector procurement opportunity.
These rules are linked to the work category, industry, or regulated service area.
Act 38 of 2000
Important for public-sector construction and infrastructure tenders that require contractor grading or construction procurement standards.
Relevant because this tender appears to involve engineering, technical design, maintenance, or regulated built-environment work.
Act 85 of 1993
Sets health and safety duties for contractors, employers and service providers working on public-sector sites.
Relevant because this tender appears to involve engineering, technical design, maintenance, or regulated built-environment work.
Act 46 of 2000
Relevant where professional engineering services or regulated engineering work may be required.
Relevant because this tender appears to involve engineering, technical design, maintenance, or regulated built-environment work.
Address
393 Witkopies Farm - Olifantsfontein - Centurion - 1665
Source confidence
High source confidence
Official source
eTenders.gov.za
Documents found
17
Last checked
26 Nov 2026
AI status
Enhanced
Data conflicts
None detected
This tender has strong source evidence, including source metadata and supporting tender information synced from the government tender portal.
Tenders SA is not the issuing authority. All tenders are automatically synced from the official government tender portal. Always confirm final submission details, closing dates, briefing sessions, eligibility requirements, and documents on the official government portal before applying.
Key Personnel
Provinces Active
Industries
Learn how to submit a winning bid with these related articles
A technical guide to municipal electrical tenders. Covers CIDB EB/EP grading, electrification projects (INEP), substation maintenance panels, and COC compliance.
How mechanical and electrical engineers, contractors, and consultants can win public sector contracts in South Africa — HVAC, plumbing, fire systems, electrical infrastructure, ECSA registration, CIDB ME designation, and tender documentation essentials.
How small electrical contractors use Joint Ventures to combine EP grading, win Eskom and municipal infrastructure projects, and compete for renewable energy installations.
Provincial procurement is not national procurement with a different address. Learn how provincial departments, entities, metros and districts buy, when they buy, and how to choose the province where your business can actually win.
💡 Want more tendering tips and strategies?
Explore Our BlogGet deep intelligence on Services: Electrical. Unlock full pricing strategies, bid frequency, and historical win rates.