Broad-Based Black Economic Empowerment Act (B-BBEE Act)
Act 53 of 2003
Provides the empowerment-compliance context often used in public-sector supplier evaluation.
Relevant because this is a South African public-sector procurement opportunity.
Documents available on tender detail page
Tender Type
Request for Bid(Open-Tender)
Delivery Location
Dr Harry Surtie Hospital, 26 Corner of Upping Drive & turner Str,Upington 8801 - Dr Harry Surtie Hospital, 26 Corner of Upping Drive & turner Str,Upington 8801 - Upington - 8801
Organization Type
GOVERNMENT
Published
28 Nov 2026
OCDS Reference
ocds-9t57fa-180431
The northern cape department of health requires the supply, delivery, installation and demonstration of a ceiling-suspended dual detector x-ray system for the main x-ray department at dr harry surtie hospital in upington. Bidders must attend a compulsory briefing session, submit a complete set of returnable documents including csd and tax compliance proof, and provide evidence of relevant experience. The contract is for a firm three-year period, and bids will be evaluated on an 80/20 or 90/10 preference point system with specific goals for black, female, youth and disabled owned companies.
Compulsory briefing session: 10 December 2026 at 10:00 at Dr Harry Surtie Hospital, Upington. Attendance is mandatory.
Closing: 21 December 2026 at 11:00. Submit a sealed envelope marked with bid number NCDOH/021/HS/2026 and description, deposited in the Bid Box at the Reception area of James Exum Building, Robert Mangaliso Sobukwe Hospital Complex, Du Toitspan Road, Belgravia, Kimberley, 8300.
Returnable documents: SBD 1, SBD 3.1–3.3, SBD 4, SBD 6.1, valid Tax Compliance Status PIN, full CSD registration report (not older than 14 days before closing), certified CIPC/CIPRO registration, certified ID copies of all directors, latest two years' financial statements, reference letters or award letters for previous work, initialled General Conditions of Contract, and all addendums.
Functionality: submit reference letters or award letters on official letterhead with contact details, respond to Annexure A technical specifications (each page initialled), and present a positive bank guarantee of the quoted amount or a bank rating for the quoted amount.
Pricing: firm price for three years including employee increments, inclusive of VAT. Bids must remain valid for 120 days from closing. The tender is awarded per item; bidders may tender for one or more items.
Specific goals: points for 100% Black Owned (10/5), 100% Female Owned (2/4), 100% Youth Owned (2/4), and 100% Disabled Owned (1/2) companies, verified via CSD. Submit proof to claim points; otherwise score 0.
Disqualification risks: late submission, incomplete or unsigned forms, unauthorised alterations, bids not in the correct bid box, conditional offers, or unbalanced rates not adjusted within 3 days of notification.
Date & Time
Monday, 21 December 2026 - 11:00
Venue
Dr Harry Surtie Hospital, 26 Corner of Upping Drive & turner Str,Upington 8801
Important: Attendance at this briefing session is mandatory. Bids from suppliers who do not attend may be disqualified.
Categories
Request for Bid(Open-Tender)
Dr Harry Surtie Hospital, 26 Corner of Upping Drive & turner Str,Upington 8801 - Dr Harry Surtie Hospital, 26 Corner of Upping Drive & turner Str,Upington 8801 - Upington - 8801
Tenders in this industry often require registration with these bodies.
Recommended Certifications
Having these can improve your winning chances: SANC Registration, SAPC Registration, ISO 15189 (Medical Laboratory Quality)
AI Document Analysis Stages
Submission Guidelines
Source: General Conditions of Contract.pdf (TENDER)28 Nov
2026
Tender Published
Tender was published
21 Dec
2026
Closing Date
Tender closing date
These references help suppliers understand the public-procurement framework around this opportunity. They are generated from the tender category, issuing organisation type and procurement context.
These rules commonly apply to South African public-sector procurement.
Act 53 of 2003
Provides the empowerment-compliance context often used in public-sector supplier evaluation.
Relevant because this is a South African public-sector procurement opportunity.
Act 108 of 1996 (s217)
This is general procurement context, not legal advice. Always verify requirements in the official tender documents and issuing authority notices.
ANNEXURE A - (Specifications for Ceiling Suspension machine for Main X-rays).pdf
Supply, delivery, installation, demonstration and commissioning of a ceiling-suspended dual-detector digital X-ray machine for the main X-ray unit at Dr Harry Surtie Hospital in Upington, Northern Cape Department of Health. The unit must perform routine diagnostic imaging, including general radiography and orthopaedics for adults and paediatrics, and must include two flat-panel detectors, a ceiling-suspended tube, an examination table, an erect wall stand, and a digital workstation with DICOM/PACS connectivity. The successful bidder must also de-install the current condemned X-ray machine and place it in storage on hospital premises.
General Conditions of Contract.pdf
Supply, delivery, installation and demonstration of a ceiling suspended dual detector X-ray system for the main X-ray department at Dr Harry Surtie Hospital, under the Northern Cape Department of Health. The contract is governed by the National Treasury General Conditions of Contract (GCC), which set out standard terms for performance security, warranties, payment, penalties and dispute resolution.
BID NOTICE 28-11-2026.pdf
Supply, delivery, installation and demonstration of a ceiling suspended dual detector X-ray system for the main X-ray department at Dr Harry Surtie Hospital, Upington, under a three-year firm-price contract. The Northern Cape Department of Health will evaluate bids under the PPPFA 2022 regulations using either the 80/20 or 90/10 preference point system.
To download these documents and access AI-powered analysis, visit the main tender page.
Organization
Northern Cape - HealthFind Department of Health tenders with AI Discovery, SAHPRA compliance, and intelligence for pharmaceutical and medical services.
Matched by category & region
Free guidance to prepare before you bid
Not sure if your business is ready for this tender? Check CSD, CIDB, and B-BBEE requirements, run a readiness assessment, and move from opportunity to submission.
Open Supplier Readiness HubMedian Estimate
R 192 951
Range
Based on 25 comparable awarded tenders. Companies with similar profiles typically bid near the median.
* Estimates are based on historical data and do not guarantee actual award values.
We refine every tender document through these stages so you can brief your team and prepare your bid with confidence. Anything marked as "in progress" will be upgraded automatically — no action required from you.
Returnable documents: the bid must be submitted with all required forms completed and signed. The specific returnable forms are not listed in the available document. The General Conditions of Contract (GCC) apply to all bids and may not be amended. The successful bidder must provide a performance security within 30 days of contract award, in the form and amount specified in the Special Conditions of Contract (SCC).
Evaluation Criteria
Source: General Conditions of Contract.pdf (TENDER)Bidders must have a valid tax clearance certificate from SARS prior to award. Bidders must not be involved in collusive bidding or restrictive practices as defined in the Competition Act. Bidders must not have engaged in corrupt or fraudulent practices. The contract is subject to the National Industrial Participation Programme (NIPP) where applicable. No specific scoring split or minimum qualifying score is stated in the available document.
Technical Specifications
Source: General Conditions of Contract.pdf (TENDER)The tender is for the supply, delivery, installation and demonstration of a ceiling suspended dual detector X-ray for the main X-ray at Dr Harry Surtie Hospital. No further technical specifications are provided in the available document.
Quality Management
Source: General Conditions of Contract.pdfGoods must conform to standards specified in the bidding documents and specifications. Inspection, testing and analysis may be carried out; if goods do not comply, the supplier bears the cost and may be required to replace them.
Financial Requirements
Source: General Conditions of Contract.pdf (TENDER)Performance security: the successful bidder must furnish a performance security within 30 days of contract award, in the form and amount specified in the SCC. Acceptable forms include a bank guarantee, irrevocable letter of credit, or cashier's/certified cheque. Payment will be made in Rand unless otherwise stipulated in the SCC, and no later than 30 days after submission of a valid invoice. Prices quoted in the bid may not vary except as authorised in the SCC or bid validity extension.
Compliance Requirements
Source: General Conditions of Contract.pdf (TENDER)Tax clearance: a valid tax clearance certificate from SARS is required prior to award. The certificate must be an original issued by SARS. Bidders must not be involved in collusive bidding or restrictive practices as defined in the Competition Act. Bidders must not have engaged in corrupt or fraudulent practices. The contract is subject to the National Industrial Participation Programme (NIPP) where applicable.
Contractual Terms
Source: General Conditions of Contract.pdfThe General Conditions of Contract (GCC) apply. Key provisions include: performance security required within 30 days of award; goods must conform to specified standards; supplier must indemnify against patent infringement; inspections and tests may be conducted at the supplier's cost if non-compliant; packing must protect goods during transit; delivery and documents per SCC; insurance required; warranty of 12 months after delivery or 18 months after shipment, whichever is earlier; payment within 30 days of invoice; prices fixed unless adjusted per SCC; no assignment without consent; subcontracts must be notified; delays may incur penalties at prime interest rate per day; termination for default possible; force majeure relief; disputes resolved via consultation, then mediation, then court; governing law South African; taxes and duties for local supplier until delivery; no contract with bidder whose tax matters are not in order; NIPP applicable; restrictive practices prohibited.
Section
Source: General Conditions of Contract.pdfNo additional evaluation criteria are stated in the available document.
Description
Source: ANNEXURE A - (Specifications for Ceiling Suspension machine for Main X-rays).pdfThe department requires the supply, delivery, installation, demonstration and commissioning of a ceiling suspended, dual detector X-ray machine for the main X-ray unit at Dr Harry Surtie Hospital in Upington. The scope of work will be discussed and finalised on the day of the compulsory site visit. Bidders not present at the site inspection will be excluded. The x-ray room where the new machine will be installed is currently a general x-ray room with an existing X-ray machine. The successful bidder must de-install the current condemned general machine and place it in storage on the hospital premises. The scope of work includes changes to make the room compliant with radiation, infection control and optimal patient safety/privacy requirements.
Important Dates
Source: ANNEXURE A - (Specifications for Ceiling Suspension machine for Main X-rays).pdf (unknown)Compulsory site visit:
Closing date: 21 December 2026 at 09:00 (from tender record).
Contact Information
Source: ANNEXURE A - (Specifications for Ceiling Suspension machine for Main X-rays).pdf (unknown)Enquiries:
Submission address: not stated in the document.
Submission Guidelines
Source: ANNEXURE A - (Specifications for Ceiling Suspension machine for Main X-rays).pdf (unknown)Returnable documents — all must be completed, signed and submitted with the bid:
Disqualification risks:
Evaluation Criteria
Source: ANNEXURE A - (Specifications for Ceiling Suspension machine for Main X-rays).pdf (unknown)Evaluation stages:
Mandatory technical requirements:
Technical Specifications
Source: ANNEXURE A - (Specifications for Ceiling Suspension machine for Main X-rays).pdf (unknown)Scope of work:
Key technical requirements:
General technical and safety:
Warranty and maintenance:
Experience & Qualifications
Source: ANNEXURE A - (Specifications for Ceiling Suspension machine for Main X-rays).pdfBidders must have an established service and repair facility and must state the facilities, name, address and telephone number of the service department. Technicians must be qualified and factory equivalent trained to deal with service, repair and calibration of the equipment quoted on. Certified copies of qualifications (or equivalent) training must be submitted with the bid. Bidders must state how many technicians they have permanently employed and attach their Curriculum Vitae. Bidders must state if the technicians are in direct employ of the bidder.
Quality Management
Source: ANNEXURE A - (Specifications for Ceiling Suspension machine for Main X-rays).pdfThe workstation must allow manual entry of patient data for emergencies or when the network is down, via a touch screen system integrated into the console. The workstation must automatically send a selected study to a DICOM compatible CD/DVD writer. The system must allow swapping patient images from one folder to the next, including patient name amendment, free text annotation for entering kV, mA and time of studies. Predefined anatomically specific processing sets must be available, with manual customisation possible. DICOM grayscale display, Fast Ethernet interface, fully customized patient worklist, and examination related pre-configured views are required. The entire Local Area Network required for the system must be supplied and installed by the successful bidder where necessary. Quality Control software must be included as a standard. The 5-year maintenance plan must include all quality checks and quality assurance requirements, including calibrations, software updates and upgrades. Maintenance and repair of air conditioners must be included during the 5-year maintenance contract period. Bidders must indicate exclusions on the maintenance plan and provide a separate quote from the bid price.
Financial Requirements
Source: ANNEXURE A - (Specifications for Ceiling Suspension machine for Main X-rays).pdf (unknown)Pricing format:
No bid security, bonds, guarantees, retention or payment terms are stated in the document.
Compliance Requirements
Source: ANNEXURE A - (Specifications for Ceiling Suspension machine for Main X-rays).pdf (unknown)Mandatory compliance:
Health & Safety
Source: ANNEXURE A - (Specifications for Ceiling Suspension machine for Main X-rays).pdfThe equipment must comply with IEC601-1 and 601-1-2 for medical equipment, with certification attached. The system must comply with ISO 900 and ISO 13458 standards, with proof of compliance. All electrical/electronic medical equipment must be licensed by Radiation Control, where applicable, and a copy of the license must be submitted. The table movement must have a safety mechanism for protection of patient and unit in the downward movement. An emergency button must be accessible and not protruding outside the table frame range. The room must be made compliant with radiation, infection control and optimal patient safety/privacy requirements. If the equipment appears on the schedule of Hazardous Substances, a license in terms of Act 15/1973 must be registered under the bidder's name, or a letter of Joint Venture must be submitted by the license holder. Software changes that are corrective in nature and initiated due to software errors, regulatory requirements or safety reasons shall be delivered and installed at no charge for the life of the equipment.
Contractual Terms
Source: ANNEXURE A - (Specifications for Ceiling Suspension machine for Main X-rays).pdfAll electrical/electronic medical equipment must be licensed by Radiation Control, where applicable, and a copy of the license must be submitted. The bidder must be prepared to provide a unit for technical evaluation and clinical assessment on request. Spare parts must be guaranteed available for the specified life of the equipment, with a minimum of 10 years. The tender price must include delivery, installation, commissioning, two-year warranty and training. If the equipment is taken away for repairs during the warranty period, a loan set must be supplied for use by the institution. The up-time of the unit must be better than 98%, excluding scheduled preventative maintenance and software upgrades, measured on a quarterly basis. If the up-time is lower than 98%, the shortfall will be added to the warranty period, and a sliding scale penalty clause will form part of the service contract, reducing maintenance payment by a pro rata amount. Up-time is defined as 24/7, i.e. 8760 hours per annum; a down time of 2% relates to 175 hours per annum. The bidder must supply a minimum of twenty-four-month warranty against poor workmanship and latent defects and parts, all inclusive, including all parts (including consumables, x-ray tubes and other glassware), labour, travelling and accommodation, servicing, quality assurance, calibrations and software updates. The warranty commences after formal acceptance and handover of the equipment. Maintenance of air conditioners must be included during the warranty period. The bidder must supply a separate 5-year, all inclusive, fully comprehensive preventative maintenance, service repair plan covering all equipment, hardware and software, with a fully costed comprehensive maintenance and service agreement with an option to enter into a renewable agreement for the specified lifespan of the equipment. The 5-year plan must include all parts, labour, travelling and accommodation, service and maintenance, quality checks, calibrations, software updates and upgrades, and maintenance of air conditioners. Bidders must indicate exclusions on the maintenance plan and provide a separate quote from the bid price.
Section
Source: ANNEXURE A - (Specifications for Ceiling Suspension machine for Main X-rays).pdfThe bidder must provide a fully automatic, digital, radiographic examination and evaluation workstation based on detector technology for high image dynamics with excellent signal/noise ratio. The system must include a digital detector of amorphous silicon and caesium iodide flat panel for excellent image quality even with low dose. The workstation must provide a mechanism to support quality review of DR images and permit a radiographer to take remedial actions, including image flip, rotation, window width and level, image rejection and reprocessing.
Description
Source: BID NOTICE 28-11-2026.pdfThe Northern Cape Department of Health requires the supply, delivery, installation, and demonstration of a ceiling-suspended dual detector X-ray for the main X-ray department at Dr Harry Surtie Hospital. The tender is issued under bid number NCDOH/021/HS/2026. The department encourages provincially based bidders and participation of small and emerging businesses.
Important Dates
Source: BID NOTICE 28-11-2026.pdf (TENDER)Closing date: 21 December 2026 at 11:00
Compulsory briefing session: 10 December 2026 at 10:00 at Dr Harry Surtie Hospital, Upington
Bid published: 27 November 2026
Contact Information
Source: BID NOTICE 28-11-2026.pdf (TENDER)Technical enquiries:
Admin enquiries:
Submission address:
Reception area of James Exum Building
Robert Mangaliso Sobukwe Hospital Complex
Department of Health
Du Toitspan Road
Belgravia, Kimberley, 8300
Submission Guidelines
Source: BID NOTICE 28-11-2026.pdf (TENDER)Submission method: sealed envelope deposited in the Bid Box at the Reception area of James Exum Building, Robert Mangaliso Sobukwe Hospital Complex, Department of Health, Du Toitspan Road, Belgravia, Kimberley, 8300.
Closing time: 11:00 on 21 December 2026.
Envelope must be clearly marked with the bid number and description: "Bid No: NCDOH/021/HS/2026: SUPPLY, DELIVERY, INSTALLATION AND DEMONSTRATION AND CEILING SUSPENDED DUAL DETECTOR X-RAY FOR MAIN X-RAY AT DR HARRY SURTIE HOSPITAL".
Bids must be submitted on the official forms provided; retyped or redrafted forms will be rejected.
Bids must be complete in all respects; incomplete bids may be disqualified.
Bids must be in black ink; corrections must be made by drawing a line through the error, writing the correction above, and initialling it. Use of correcting fluid is prohibited.
Only certified copies of documents should be submitted; the department accepts no responsibility for original documents.
Bids will not be accepted by fax, email, or any electronic means.
Late bids will not be considered.
Returnable forms (all must be completed, signed, and submitted):
Disqualification risks:
Evaluation Criteria
Source: BID NOTICE 28-11-2026.pdf (TENDER)Evaluation is carried out in three phases:
Phase 1 – Compliance with statutory (mandatory) requirements: verification of returnable documents and eligibility.
Phase 2 – Functionality: assessment of previous work done (reference letters or award letters on official letterhead with contact details), response to Annexure A technical specifications, and presentation of a positive bank guarantee of the quoted amount or bank rating for the quoted amount.
Phase 3 – Price and specific goals: price points calculated using the 80/20 or 90/10 preference point system, plus points for specific goals.
Preference point system: 80/20 or 90/10, as determined by the estimated value of the contract (80/20 for up to R50 million, 90/10 for above R50 million).
Price points: maximum 80 or 90 points, awarded to the lowest acceptable price; other bidders receive points proportionately.
Specific goals points (maximum 20 for 80/20 system, 10 for 90/10 system):
Specific goals are verified via the Central Supplier Database (CSD).
Bidders who do not submit proof for specific goals will score 0 for those points but will not be disqualified.
Tie-breaking: if two or more bidders have equal total points, the bidder with the highest specific goals points wins; if still equal, the bidder with the highest functionality percentage wins; if still equal, the winner is drawn by lots.
The department is not obliged to award to the highest or lowest scoring bidder.
Technical Specifications
Source: BID NOTICE 28-11-2026.pdf (TENDER)Supply, delivery, installation, and demonstration of a ceiling-suspended dual detector X-ray for the main X-ray department at Dr Harry Surtie Hospital.
Bidders must carefully read the technical specifications (Annexure A) and respond accordingly.
Each page of the technical specification must be initialled and submitted with the bid.
The department requires services to be rendered from an office located in any of the five districts within the Northern Cape.
Experience & Qualifications
Source: BID NOTICE 28-11-2026.pdfBidders must provide evidence of actual experience, including:
Pricing Schedule
Source: BID NOTICE 28-11-2026.pdfPricing must be in Rand, including VAT.
Prices must be tendered in accordance with the units specified in the specification.
Where a quantity is given, a rate and price (quantity × rate) must be inserted.
The successful tenderer must fulfil the specifications and outcomes for the items tendered.
Only items with a positive rand value in the pricing schedule will be considered as valid tenders; any other notation means the item is not tendered for.
Nil rates may be clarified, and the employer may perform a risk analysis on the reasonableness of rates.
Fixed rates and prices are required for the duration of the contract, not subject to adjustment except as provided in the Conditions of Contract.
The tender will be awarded per item; bidders may tender for one or more items and need not tender for all items.
The successful bidder must complete a Quotation Pricing Schedule reflecting all costs including delivery, transportation, VAT, and disbursements.
Pricing must be in line with the bid specifications.
Bidders must indicate which services they are unable to provide.
Financial Requirements
Source: BID NOTICE 28-11-2026.pdf (TENDER)Pricing format: fixed rates and prices in Rand, including VAT, for the duration of the contract (firm price for three years, including employee increments).
Prices must be tendered in accordance with the units specified in the specification.
Where a quantity is given, a rate and price (quantity × rate) must be inserted.
Only items with a positive rand value in the pricing schedule will be considered as valid tenders for that item.
The tender will be awarded per item; bidders may tender for one or more items and need not tender for all items.
The successful bidder must complete a Quotation Pricing Schedule reflecting all costs, including delivery, transportation, VAT, and disbursements.
Bidders must indicate which services they are unable to provide.
Bids must include VAT in their rates.
Bidders must present a positive bank guarantee of the quoted amount or a bank rating for the quoted amount.
Bidders must submit the latest two years' financial statements.
Bids must remain valid for 120 days from the closing date.
If a bidder fails to enter into a contract after acceptance, they may be liable for additional costs incurred by the department.
Compliance Requirements
Source: BID NOTICE 28-11-2026.pdf (TENDER)CSD registration: bidders must be registered on the Central Supplier Database and submit a full CSD registration report not older than 14 days before closing.
Tax compliance: bidders must submit a valid SARS Tax Compliance Status PIN; a printed TCS certificate may also be submitted.
CIPC registration: certified CIPC/CIPRO company registration documents required.
Identity documents: certified copies of identity documents of all directors required.
State employment: bids from persons in the service of the state, or companies with directors who are state employees, will not be considered.
Joint ventures: each party must comply individually with all compliance requirements.
B-BBEE: a B-BBEE status level verification certificate or sworn affidavit (for EMEs and QSEs) must be submitted to qualify for preference points.
Minimum wage: bids proposing wages below the sector determination will be rejected.
Local economic development: bidders are encouraged to be provincially based; services must be rendered from an office in one of the five Northern Cape districts.
POPIA: successful bidders must comply with the Protection of Personal Information Act and sign the NCDOH standard Non-Disclosure Agreement.
Contractual Terms
Source: BID NOTICE 28-11-2026.pdfSpecial Conditions of Contract prevail over General Conditions where they conflict.
Bids must remain valid for 120 days from closing date.
A bidder may withdraw its bid by written notice before the conclusion of the evaluation process.
If a bidder fails to enter into a contract after acceptance, it may be liable for additional costs incurred by the department.
The bidder indemnifies the department against claims for damage to persons or property arising from contract execution.
Bids proposing wages below the sector minimum will be rejected.
A firm price for three years, including employee increments, is required.
The department may reject bids with items not originally included, conditional or incomplete offers, or unbalanced rates not adjusted within 3 days of notification.
The department is not bound to accept any bid and may accept the whole or part of a bid.
If the bidder fails to deliver per contractual obligations without valid reasons, the department may cancel the contract.
Successful bidders must provide professional, objective, and impartial services, and must disclose any conflict of interest; non-disclosure is grounds for termination.
Successful bidders must comply with POPIA and sign the NCDOH standard Non-Disclosure Agreement.
The department reserves the right to withdraw the bid at any time without notice or liability, and to perform due diligence including site visits.
Section
Source: BID NOTICE 28-11-2026.pdfFunctionality evaluation includes:
Sets the constitutional standard for fair, equitable, transparent, competitive and cost-effective public procurement.
Relevant because this is a South African public-sector procurement opportunity.
Act 5 of 2000
Covers preferential procurement and preference-point systems used in public tenders.
Relevant because this is a South African public-sector procurement opportunity.
Act 12 of 2004
Supports anti-corruption controls and supplier integrity in procurement processes.
Relevant because this is a South African public-sector procurement opportunity.
Act 28 of 2024
Provides the national framework for public procurement across government.
Relevant because this is a South African public-sector procurement opportunity.
Act 2 of 2000
Supports access to tender records, award decisions and public-sector procurement information.
Relevant because this is a South African public-sector procurement opportunity.
Act 3 of 2000
Supports lawful, reasonable and procedurally fair administrative tender decisions.
Relevant because this is a South African public-sector procurement opportunity.
These rules are linked to the work category, industry, or regulated service area.
Act 61 of 2003
Relevant to healthcare services, public health facilities and health-sector procurement.
Relevant because this tender appears to involve health services, public health facilities, clinical services, or medical procurement.
Act 85 of 1993
Sets health and safety duties for contractors, employers and service providers working on public-sector sites.
Relevant because this tender appears to involve health services, public health facilities, clinical services, or medical procurement.
Address
Dr Harry Surtie Hospital, 26 Corner of Upping Drive & turner Str,Upington 8801 - Dr Harry Surtie Hospital, 26 Corner of Upping Drive & turner Str,Upington 8801 - Upington - 8801
Source confidence
High source confidence
Official source
eTenders.gov.za
Documents found
3
Last checked
29 Nov 2026
AI status
Enhanced
Data conflicts
None detected
This tender has strong source evidence, including source metadata and supporting tender information synced from the government tender portal.
Tenders SA is not the issuing authority. All tenders are automatically synced from the official government tender portal. Always confirm final submission details, closing dates, briefing sessions, eligibility requirements, and documents on the official government portal before applying.
Learn how to submit a winning bid with these related articles
A comprehensive guide to securing medical equipment maintenance tenders in South African public hospitals. Learn about SLA management, OEM certifications, and clinical engineering requirements.
A strategic guide for medical equipment suppliers, maintenance companies, and healthcare technology providers bidding for tenders across South Africa's nine provincial health departments. Covers SAHPRA registration, OEM authorisation, service level agreements, and technical evaluation criteria.
How small healthcare providers, pharmacies, and medical suppliers use Joint Ventures to win provincial health department tenders by combining clinical expertise, distribution capacity, and B-BBEE credentials.
As a General supplier in Gauteng, it is essential to understand the schedule classification of medical devices and its impact on tender eligibility. In 2026, the South African government continues to prioritize healthcare, and medical device procurement plays a critical role in this endeavor. The current regulatory environment demands strict compliance with various laws and regulations, making it crucial for suppliers to ensure they meet the necessary requirements. In this article, we will provide a comprehensive guide on the schedule classification of medical devices and its implications for General suppliers in Gauteng.
💡 Want more tendering tips and strategies?
Explore Our BlogGet deep intelligence on Supplies: Medical. Unlock full pricing strategies, bid frequency, and historical win rates.